3 . FLOOR / CEILING TYPE :
AB 18-24FBBJ, AB 18-24UBBJ
D2D_AB002E/02
2006.03.15
3-1. FEATURE
MODELS :
AB 18FBBJ / AO 18FNBK
AO 18FNBN
AB 18UBBJ / AO 18UNBKL
AO 18UNBNL
AB 24FBBJ / AO 24FNBK
AO 24FNBN
AB 24UBBJ / AO 24UNBKL
AO 24UNBNL
FEATURES
FLOOR / CEILING TYPE
AB18-24
Compact design
Symmetrical thin and compact design
Flat and round form
Flexible installation
FLOOR / CEILING TYPE
AB18-24
FLOOR
Double auto swing
Combination of up/down and right/left air
direction swing allows three-dimensional air
direction control.
Since up/down air direction flaps operate
automatically, according to the operating
mode of the unit, it is possible to set the air
direction based on the operating mode.
Super vane
The double-flap "Super Vane" with newly
developed special configuration boosts
the air flow, sending cool air quickly to
every corner of the room.
Others
Auto Restart
CEILING
RIGHT and LEFT
swing
Swing
5 steps selectable
New modelOld model
Non-operation modeOperation mode
Steps
UP and DOWN
swing
7 steps selectable
Detachable and Washable Open Panel
Auto Shut Flaps
- (03 - 01) -
3-2. REMOTE CONTROLLER
3-2-1.
FEATURES
FLOOR / CEILING TYPE
AB18-24
WIRELESS REMOTE CONTROLLER
Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible.
Four kinds of timers. Easy operation.
Easy to change transmission code (4 patterns) by button operation.
Built-in timers
Select from four different timer programs (On/Off/Program/Sleep).
Program timer
The program timer operates the ON and OFF timer once within a 24 hour period.
FLOOR / CEILING TYPE
AB18-24
Sleep timer
The sleep timer function automatically corrects the temperature thermostat setting according to
the time setting to prevent excessive cooling and heating while sleeping.
Cooling operation/dry operation
When the sleep timer is set, the set temperature
automatically rises 1 °C every hour. The set
temperature can rise up to a maximum of 2 °C.
Timer setting
60min.
1 °C
2 °C
Heating operation
When the sleep timer is set, the set temperature
automatically drops 1 °C every 30 minutes. The
set temperature can drop to a maximum of 4 °C.
1 °C
2 °C
3 °C
4 °C
30min.
60min.
90min.
Timer setting
Easy operation
After code change
Mixed-up
• Code selector switch eliminates unit
being wrongly switched.
(Up to 4 codes can be set.)
ABCD
AB
C
D
•Wide and precise
transmitting range.
1. Press the MASTER CONTROL
button for more than five seconds
to start the code change.
2. Press the (+) or (-) button to
select the desired code.
A B C D
3. Press the MASTER CONTROL
button again to end the code
change.
- (03 - 02) -
FUNCTIONS
5
1
START/STOP button
Pressed to start and stop operation
64
Display
2
Set temp./Set time buttons/Set remote controller
custom code buttons
Sets the indoor temp./Sets the current time and on-off time
/Set R.C. custom code
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB.
Heating:Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB.
Heating:Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
mm
- (03 - 05) -
3-4. DIMENSIONS
3-4-1. OUTDOOR UNIT
MODELS : AO 18F, AO 18U, AO 24F, AO 24U
Top view
(Unit : mm)
FLOOR / CEILING TYPE
AB18-24
650
12
830
Front view
Bottom
Air flow
343
350
320
Side view
FLOOR / CEILING TYPE
AB18-24
154
101
58
90
MOUNTING POSITION
When there are obstacles at the
back or front sides.
100 mm
or more
600 mm
or more
Bottom view
100 mm
or more
603
When there are obstacles at the
back, side(s), and top.
600 mm or more
300 mm
250 mm
(
Ser
v
or
i
c
mor
e
s
pac
e)
or more
e
When there are obstacles at the
back, side with the installation of
more than one unit.