Note: CETL or CUL certification only applies to unbundled units and units packaged with limited
circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only.
INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of
Generac’s success in providing the most reliable generators possible. Generac’s GForce engine lineup offers added peace of mind and reliability for when you need it
the most. The G-Force series engines are purpose built and designed to handle the
rigors of extended run times in high temperatures and extreme operating conditions.
TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave
form produce less than 5% Total Harmonic Distortion for utility quality power. This
allows confident operation of sensitive electronic equipment and micro-chip based
appliances, such as variable speed HVAC systems.
TEST CRITERIA:
PROTOTYPE TESTED NEMA MG1-22 EVALUATION
SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY
MOBILE LINK™ WI-FI CONNECTIVITY: FREE with select Guardian Series home
standby generators, Mobile Link Wi-Fi allows users to monitor the status of the
generator from anywhere in the world using a smartphone, tablet, or PC. Easily
access information such as the current operating status and maintenance alerts.
Users can connect an account to an authorized service dealer for fast, friendly, and
proactive service. With Mobile Link, users are taken care of before the next power
outage.
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:This
state-of-the-art power maximizing regulation system is standard on all Generac
models. It provides optimized FAST RESPONSE to changing load conditions and
MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the
surge loads to the engine. Digital voltage regulation at ±1%.
SINGLE SOURCE SERVICE RESPONSEfrom Generac’s extensive dealer network
provides parts and service know-how for the entire unit, from the engine to the
smallest electronic component.
GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with
GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC
product line is offered with its own transfer systems and controls for total system
compatibility.
®
Engine
Generac G-Force designMaximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
10/13/16 kW
“Spiny-lok” cast iron cylinder wallsRigid construction and added durability provide long engine life.
Electronic ignition/spark advance These features combine to assure smooth, quick starting every time.
2 of 6
Full pressure lubrication systemPressurized lubrication to all vital bearings means better performance, less maintenance, and longer
Low oil pressure shutdown systemShutdown protection prevents catastrophic engine damage due to low oil.
High temperature shutdownPrevents damage due to overheating.
Generator
Revolving fieldAllows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature
Skewed statorProduces a smooth output waveform for compatibility with electronic equipment.
Displaced phase excitationMaximizes motor starting capability.
Automatic voltage regulationRegulating output voltage to ±1% prevents damaging voltage spikes.
UL 2200 listedFor your safety.
Transfer Switch (if applicable)
Fully automaticTransfers vital electrical loads to the energized source of power.
NEMA 3RCan be installed inside or outside for maximum flexibility.
Remote mountingMounts near an existing distribution panel for simple, low-cost installation.
Features and Benefits10/13/16 kW
rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.
engine life. Now featuring up to a 2 year/200 hour oil change interval.
generator.
Evolution™ Controls
AUTO/MANUAL/OFF illuminated buttonsSelect the operating mode and provide easy, at-a-glance status indication in any condition.
Two-line multilingual LCDProvides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences.
Sealed, raised buttonsSmooth, weather-resistant user interface for programming and operations.
Utility voltage sensingConstantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
Generator voltage sensingConstantly monitors generator voltage to verify the cleanest power is delivered to the home.
Utility interrupt delayPrevents nuisance startups of the engine, adjustable 2–1500 seconds from the factory default setting of
5
seconds by a qualified dealer.
Engine warm-upVerifies engine is ready to assume the load. Setpoint approximately 5 seconds.
Engine cool-downAllows engine to cool prior to shutdown. Setpoint approximately 1 minute.
Programmable exerciseOperates engine to prevent oil seal drying and damage between power outages by running the generator
for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation, providing
flexibility and potentially lower fuel costs to the owner.
Smart battery chargerDelivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries.
Main line circuit breakerProtects generator from overload.
SAE weather protective enclosureSound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift-out front for easy access
to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
Enclosed critical grade mufflerQuiet, critical grade muffler is mounted inside the unit to prevent injuries.
Small, compact, attractiveMakes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.
®
Features and Benefits10/13/16 kW
Installation System
14 in (35.6 cm) flexible fuel line connectorListed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
Integral sediment trapMeets IFGC and NFPA 54 installation requirements.
10/13/16 kW
Connectivity
Ability to view generator statusMonitor your generator with a smartphone, tablet, or computer at any time via the Mobile Link application
for complete peace of mind.
Ability to view generator Exercise/Run and Total HoursReview the generator's complete protection profile for exercise hours and total hours.
Ability to view generator maintenance informationProvides maintenance information for your specific model generator when scheduled maintenance is due.
Monthly report with previous month’s activityDetailed monthly reports provide historical generator information.
Ability to view generator battery informationBuilt in battery diagnostics displaying current state of the battery.
Weather informationProvides detailed local ambient weather conditions for generator location.
3 of 6
®
Generator
Model
10/13/16 kW
Rated maximum continuous power capacity (LP)10,000 Watts* 13,000 Watts* 16,000 Watts*
Rated maximum continuous power capacity (NG) 9,000 Watts*13,000 Watts* 16,000 Watts*
Rated voltage240
Rated maximum continuous load current – 240 volts (LP/NG)41.7 / 37.554.2 / 54.266.7 / 66.7
4 of 6
Total Harmonic DistortionLess than 5%
Main line circuit breaker45 Amp60 Amp70 Amp
Phase1
Number of rotor poles2
Rated AC frequency60 Hz
Power factor1.0
Battery requirement (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum
Unit weight (lb/kg)338/153385/175420/191
Dimensions (L x W x H) in / cm48 x 25 x 29 / 121.9 x 63.5 x 73.7
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load**616565
Sound output in dB(A) at 23 ft (7 m) with generator in Quiet-Test™ low-speed exercise mode**575555
Exercise duration5 min
Engine
Engine typeGENERAC G-Force 400 SeriesGENERAC G-Force 800 Series
Number of cylinders12
Displacement460 cc816 cc
Cylinder blockAluminum w/ cast iron sleeve
Valve arrangementOverhead valve
Lifter typeSolidHydraulic
Ignition systemSolid-state w/ magneto
Governor systemElectronic
Compression ratio9.5:1
Starter12 VDC
Oil capacity including filterApprox. 1.1 qt / 1.0 LApprox. 2.2 qt / 2.1 L
Operating rpm3,600
Fuel consumption
Natural Gas ft³/hr (m³/hr)
1/2 Load
Full Load
Liquid Propane ft
1/2 Load
Full Load
Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5–7.0 in water column (0.87–1.74 kPa) for NG, 10–12 in water column (2.49–2.99 kPa) for LP
gas. For BTU content, multiply ft
Controls
Two-line plain text multilingual LCD Simple user interface for ease of operation.
Mode buttons: AUTOAutomatic start on utility failure. Weekly, Bi-Weekly, or Monthly selectable exerciser.
MANUALStart with starter control, unit stays on. If utility fails, transfer to load takes place.
OFFStops unit. Power is removed. Control and charger still operate.
Ready to Run/Maintenance messagesStandard
Engine run hours indicationStandard
Programmable start delay between 2–1500 seconds Standard (programmable by dealer only)
Utility voltage loss/Return to utility adjustable (brownout setting)From 140-171 V / 190-216 V
Future set capable exerciser/Exercise set error warningStandard
Run/Alarm/Maintenance logs 50 events each
Engine start sequence Cyclic cranking: 16 sec on, 7 sec rest (90 sec maximum duration).
Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped.
Smart Battery Charger Standard
Charger Fault/Missing AC WarningStandard
Low Battery/Battery Problem Protection and Battery Condition Indication Standard
Automatic Voltage Regulation with Over and Under Voltage Protection Standard
Under-Frequency/Overload/Stepper Overcurrent ProtectionStandard
Safety Fused/Fuse Problem ProtectionStandard
Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard
Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard
High Engine Temperature Shutdown Standard
Internal Fault/Incorrect Wiring Protection Standard
Common External Fault Capability Standard
Field Upgradable FirmwareStandard
**Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for
supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum kilovolt amps
and current are subject to and limited by such factors as fuel BTU (Megajoule) content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each
1,000 ft (304.8 m) above sea level; and also will decrease approximately 1% for each 6 °C (10 °F) above 16 °C (60 °F).
G007171-0, G007172-0
(10 kW)
101 (2.86)
3
/hr (gal/hr) [L/hr]
3
/hr x 2,500 (LP) or ft3/hr x 1,000 (NG). For Megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG).
127 (3.60)
36 (0.97) [3.66]
54 (1.48) [5.62]
G007173-0, G007174-0,
G007175-0 (13 kW)
154 (4.36)
225 (6.37)
56 (1.54) [5.83]
90 (2.45) [9.28]
Specifications10/13/16 kW
G007176-0, G007177-0,
G007178-0 (16 kW)
182 (5.15)
245 (6.94)
62 (1.70) [6.45]
109 (2.99) [11.32]
®
H2
DEPTH
H1
W2
W1
H2
DEPTH
H1
W2
W1
Switch Options10/13/16 kW
Limited Circuits Switch Features
16 space, 24 circuit. Breakers not included.
Electrically operated, mechanically-held contacts for fast, positive connections.
Rated for all classes of load, 100% equipment rated, both inductive and
resistive.
2-pole, 250 VAC contactors.
30 millisecond transfer time.
Dual coil design.
Rated for both copper and aluminum conductors.
Main contacts are silver plated or silver alloy to resist welding and sticking.
NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
Multi listed for use with 1 in standard, tandem, GFCI, and AFCI breakers from
Siemens, Murray, Eaton, and Square D for the most flexible and cost effective
install.
Dimensions
HeightWidth
H1H2W1W2
in26.7530.110.513.56.91
cm67.9476.4326.6734.1817.54
Wire Ranges
Conductor LugNeutral LugGround Lug
2/0 - #142/0 - #142/0 - #14
Depth
Model
No. of poles 2
Current rating (amps)100
Voltage rating (VAC)120 / 240, 1Ø
Utility voltage monitor (fixed)*
-Pick-up
-Dropout
Return to utility*Approx. 15 sec
Exercises bi-weekly for
5 minutes*
ETL or UL ListedStandard
Total circuits available24
Tandem breaker capabilities8 tandems
Circuit breaker protected
Available RMS Symmetrical
Fault Current @ 250 Volts
*Function of Evolution controller
Exercise can be set to weekly or monthly
G007172-0
(10 kW)
G007174-0
(13 kW)
80%
65%
Standard
10,000
G007177-0
(16 kW)
10/13/16 kW
5 of 6
Service Rated Smart Switch Features
Includes Smart A/C Management (SACM) module standard.
Intelligently manages up to four air conditioner loads with no additional
hardware.
Up to eight large (240 VAC) loads can be managed with Smart Management
Modules (SMMs).
Electrically operated, mechanically-held contacts for fast, clean connections.
Rated for all classes of load, 100% equipment rated, both inductive and
resistive.
2-pole, 250 VAC contactors.
Service equipment rated, dual coil design.
Rated for both aluminum and copper conductors.
Main contacts are silver plated or silver alloy to resist welding and sticking.
NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
Dimensions
HeightWidth
H1H2W1W2
in26.7530.110.513.56.3
cm67.9476.4526.6734.316.01
Wire Ranges
Conductor LugNeutral LugGround Lug
400 MCM - #4350 MCM - #62/0 - #14
200 Amps 120/240, 1ø
Open Transition Service Rated
Depth
Model
No. of poles 2
Current rating (amps)200
Voltage rating (VAC)120/240, 1Ø
Utility voltage monitor (fixed)*
-Pick-up
-Dropout
Return to utility*15 sec
Exercises bi-weekly for 5 minutes*Standard
ETL or UL ListedStandard
Enclosure typeNEMA/UL 3R
Circuit breaker protected22,000
Lug range250 MCM - #6
*Function of Evolution Controller
Exercise can be set to weekly or monthly
G007175-0
(13 kw)
80%
65%
G007178-0
(16 kW)
®
Model #ProductDescription
Dimensions & UPCs
648 mm
[25.5 in]
727.2 mm
[28.6 in]
637.6 mm
[25.1 in]
1232 mm
[48.5 in
]
1218 mm
[48.0 in]
LEFT SIDE VIEW
FRONT VIEW
®
G005819-026R Wet Cell Battery
10/13/16 kW
G007101-0Battery Pad Warmer
6 of 6
G007102-0Oil Warmer
G007103-1Breather Warmer
G005621-0
G007027-0 - BisqueFascia Base Wrap Kit
G005703-0 - BisqueTouch-Up Paint Kit
G006482-0 – 10 kW
G007216-0 – 13 / 16 kW
G007005-0Wi-Fi LP Fuel Level Monitor
G007000-0 (50 amps)
G007006-0 (100 amps)
G007169-0
Auxiliary Transfer Switch
Contact Kit
Scheduled Maintenance Kit
Smart Management Module
Mobile Link™ 4G LTE Cellular
Accessory
Available Accessories10/13/16 kW
Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell
battery for use with all air-cooled standby product (excluding PowerPact
The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0 °F (-18
°C). (Not necessary for use with AGM-style batteries)
.
Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0 °F (-18
°C).
The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in
climates where heavy icing occurs.
The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you
may not need. Not compatible with 50 amp pre-wired switches.
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek,
contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base.
If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future
corrosion. The paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.
Generac's scheduled maintenance kits provide all the items necessary to perform complete routine maintenance
on a Generac automatic standby generator (oil not included).
The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring
the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power
failure. Status alerts are available through a free application to notify users when the LP tank is in need of a refill.
Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages
large electrical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using
SMM’s can reduce the overall size and cost of the system.
The Mobile Link 4G LTE Cellular Accessory allows users to monitor the status of the generator from anywhere
in the world, using a smartphone, tablet, or PC. Easily access information such as the current operating status
and maintenance alerts. Users can connect an account with an authorized service dealer for fast, friendly, and
proactive service. With Mobile Link, users are taken care of before the next power outage.
®
).
ModelUPC
G007171-0696471074680
G007172-0696471074673
G007173-0696471076400
G007174-0696471077100
G007175-0696471077117
G007176-0696471076417
G007177-0696471077124
G007178-0696471077131
Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.