Note: CUL certification only applies to unbundled units and units packaged with
limited circuit switches. Units packaged with the Smart Switch are UL certified in
the USA only.
16/20/22 kW
1 of 6
FEATURES
INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac’s
success in providing the most reliable generators possible. Generac’s G-Force engine
lineup offers added peace of mind and reliability for when you need it the most. The
G-Force series engines are purpose built and designed to handle the rigors of
extended run times in high temperatures and extreme operating conditions.
TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave
form produce less than 5% Total Harmonic Distortion for utility quality power. This allows
confident operation of sensitive electronic equipment and micro-chip based appliances,
such as variable speed HVAC systems.
TEST CRITERIA:
√PROTOTYPE TESTED √ NEMA MG1-22 EVALUATION
√ SYSTEM TORSIONAL TESTED √ MOTOR STARTING ABILITY
MOBILE LINK™ REMOTE MONITORING: FREE with every Guardian Series Home
standby generator. Allows you to monitor the status of your generator from anywhere in the
world using a smartphone, tablet, or PC. Easily access information such as the current
operating status and maintenance alerts. Connect your account to your authorized service
dealer for fast, friendly and proactive service. With Mobile Link, you are taken care of before
the next power outage.
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque-matching the surge loads to the engine. Digital
voltage regulation at ±1%.
SINGLE SOURCE SERVICE RESPONSEfrom Generac’s extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
GENERAC TRANSFER SWITCHES:Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
TM
®
16/20/22 kW
Engine
Generac G-Force designMaximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
16/20/22 kW
“Spiny-lok” cast iron cylinder wallsRigid construction and added durability provide long engine life.
Electronic ignition/spark advance These features combine to assure smooth, quick starting every time.
2 of 6
Full pressure lubrication systemPressurized lubrication to all vital bearings means better performance, less maintenance and longer engine
Low oil pressure shutdown systemShutdown protection prevents catastrophic engine damage due to low oil.
High temperature shutdownPrevents damage due to overheating.
Generator
Revolving field
Skewed statorProduces a smooth output waveform for compatibility with electronic equipment.
Displaced phase excitation
Automatic voltage regulationRegulates the output voltage to ±1% prevents damaging voltage spikes.
UL 2200 listedFor your safety.
Transfer Switch (if applicable)
Fully automaticTransfers your vital electrical loads to the energized source of power.
NEMA 3RCan be installed inside or outside for maximum flexibility.
Remote mountingMounts near your existing distribution panel for simple, low-cost installation.
features and benefits
rings helps the engine run cooler, reducing oil consumption resulting in longer engine life.
life. Now featuring up to a 2 year/200 hour oil change interval.
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature
generator.
Maximizes motor starting capability.
Evolution™ Controls
Auto/Manual/Off illuminated buttonsSelects the operating mode and provides easy, at-a-glance status indication in any condition.
Two-line LCD multilingual displayProvides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
Sealed, raised buttonsSmooth, weather-resistant user interface for programming and operations.
Utility voltage sensingConstantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
Generator voltage sensingConstantly monitors generator voltage to ensure the cleanest power delivered to the home.
Utility interrupt delayPrevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of
five (5) seconds by a qualified dealer.
Engine warm-upEnsures engine is ready to assume the load, setpoint approximately 5 seconds.
Engine cool-down
Programmable exerciseOperates engine to prevent oil seal drying and damage between power outages by running the generator
SAE weather protective enclosureSound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
Enclosed critical grade mufflerQuiet, critical grade muffler is mounted inside the unit to prevent injuries.
Small, compact, attractiveMakes for an easy, eye appealing installation, as close as 18" (457 mm) away from a building.
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries.
Protects generator from overload.
winds up to 150 mph. Hinged key locking roof panel for security. Lift-out front for easy access to all routine
maintenance items. Electrostatically applied textured epoxy paint for added durability.
®
16/20/22 kW
Installation System
1 ft (305 mm) flexible fuel line connectorAbsorbs any generator vibration when connected to rigid pipe.
Direct-to-dirt composite mounting padComplex lattice design prevents settling or sinking of the generator system.
Integral sediment trapPrevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
Remote Monitoring
Ability to view generator status
Ability to view generator Exercise/Run and Total Hours
Ability to view generator maintenance information
Monthly report with previous month’s activity.Detailed monthly reports provide historical generator information
Ability to view generator battery informationBuilt in battery diagnostics displaying current state of the battery
Weather informationProvides detailed local ambient weather conditions for generator location
Monitor your generator via your smartphone, tablet, or computer at any time via the Mobile Link application for
complete peace of mind
Review the generator's complete protection profile for exercise hours and total hours
Provides maintenance information for your specific model generator when scheduled maintenance is due
features and benefits
16/20/22 kW
3 of 6
®
16/20/22 kW
Generator
Model
16/20/22 kW
4 of 6
Rated Maximum Continuous Power Capacity (LP)
Rated Maximum Continuous Power Capacity (NG)
Rated Voltage
Rated Maximum Continuous Load Current – 240 Volts (LP/NG)
Total Harmonic Distortion
Main Line Circuit Breaker
Phase
Number of Rotor Poles
Rated AC Frequency
Power Factor
Battery Requirement (not included)
Unit Weight (lb/kg)
Dimensions (L x W x H) in/mm
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load**
Sound output in dB(A) at 23 ft (7 m) with generator in Quiet-Test™ low-speed exercise mode**555557
Exercise duration5 min5 min5 min
Engine
Type of Engine
Number of Cylinders
Displacement
Cylinder Block
Valve Arrangement
Ignition System
Governor System
Compression Ratio
Starter
Oil Capacity Including Filter
Operating rpm
Fuel Consumption
Natural Gas ft³/hr (m³/hr)
1/2 Load
Full Load
Liquid Propane ft
1/2 Load
Full Load
Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7" water column (7-13 mm mercury) for natural gas, 10-12" water column (19-22 mm mercury)
for LP gas. For BTU content, multiply ft
Controls
Two-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation.
Mode Buttons:AutoAutomatic Start on Utility failure. 7 day exerciser.
ManualStart with starter control, unit stays on. If utility fails, transfer to load takes place.
OffStops unit. Power is removed. Control and charger still operate.
Ready to Run/Maintenance MessagesStandard
Engine Run Hours IndicationStandard
Programmable start delay between 2-1500 seconds Standard (programmable by dealer only)
Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting)From 140-171 V / 190-216 V
Future Set Capable Exerciser/Exercise Set Error WarningStandard
Run/Alarm/Maintenance Logs 50 Events Each
Engine Start Sequence Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration).
Starter Lock-out Starter cannot re-engage until 5 sec after engine has stopped.
Smart Battery Charger Standard
Charger Fault/Missing AC WarningStandard
Low Battery/Battery Problem Protection and Battery Condition Indication Standard
Automatic Voltage Regulation with Over and Under Voltage Protection Standard
Under-Frequency/Overload/Stepper Overcurrent ProtectionStandard
Safety Fused/Fuse Problem ProtectionStandard
Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard
Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard
High Engine Temperature Shutdown Standard
Internal Fault/Incorrect Wiring Protection Standard
Common External Fault Capability Standard
Field Upgradable FirmwareStandard
**Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration
of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule
content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F) above 16 °C (60 °F).
/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG)
(20 kW)
204 (5.78)
301 (8.52)
87 (2.37) [8.99]
130 (3.56) [13.48]
specifications
G007042-2, G007043-2
(22 kW)
228 (6.46)
327 (9.26)
92 (2.53) [9.57]
142 (3.90) [14.77]
®
16/20/22 kW
Limited Circuits Switch Features
16 space, 24 circuit, breakers not included.
Electrically operated, mechanically-held contacts for fast, positive
connections
Rated for all classes of load, 100% equipment rated, both inductive and
resistive.
2-pole, 250 VAC contactors.
30 millisecond transfer time.
Dual coil design.
Rated for both copper and aluminum conductors.
Main contacts are silver plated or silver alloy to resist welding and sticking.
NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effective
install.
Dimensions
HeightWidthDepth
H1H2W1W2
in26.7530.110.513.56.91
mm679.4764.3266.7343.0175.4
switch options
Model
No. of Poles 2
Current Rating (Amps)100
Voltage Rating (VAC)120 / 240, 1Ø
Utility Voltage Monitor (Fixed)*
-Pick-up
-Dropout
Return to Utility*approx. 15 sec
Exercises bi-weekly for 5 minutes*Standard
UL ListedStandard
Total Circuits Available24
Tandem Breaker Capabilities8 tandems
Circuit Breaker Protected
Available RMS Symmetrical
Fault Current @ 250 Volts
*Function of Evolution Controller
Exercise can be set to weekly or monthly
W1
H2
G007036-1 (16kW)
80%
65%
10,000
H1
16/20/22 kW
5 of 6
Wire Ranges
Conductor LugNeutral LugGround Lug
1/0 - #142/0 - #142/0 - #14
Service Rated Smart Switch Features
Includes Digital Power Management Technology standard (DPM).
Intelligently manages up to four air conditioner loads with no additional
hardware.
Up to four more large (240 VAC) loads can be managed when used in
conjunction with Smart Management Modules (SMMs).
Electrically operated, mechanically-held contacts for fast, clean connections.
Rated for all classes of load, 100% equipment rated, both inductive and resis-
tive.
2-pole, 250 VAC contactors.
Service equipment rated, dual coil design.
Rated for both aluminum and copper conductors.
Main contacts are silver plated or silver alloy to resist welding and sticking.
NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount-
ing flexibility.
Dimensions
DEPTH
Model
No. of Poles 2
Current Rating (Amps)200
Voltage Rating (VAC)
Utility Voltage Monitor (Fixed)*
-Pick-up
-Dropout
Return to Utility*approx. 13 sec
Exercises bi-weekly for 5 minutes*Standard
UL ListedStandard
Enclosure TypeNEMA/UL 3R
Circuit Breaker Protected22,000
Lug Range250 MCM - #6
W2
G007037-1 (16 kW)/G007039-1 (20 kW)/
G007043-2 (22 kW)
120/240, 1Ø
80%
65%
*Function of Evolution Controller
Exercise can be set to weekly or monthly
W1
200 Amps 120/240, 1ø
Open Transition Service Rated
HeightWidthDepth
H1H2W1W2
in26.7530.110.513.56.91
mm679.4764.3266.7343.0175.4
DEPTH
H2
W2
H1
16/20/22 kWavailable accessories
Model #ProductDescription
16/20/22 kW
G007005-0Wi-Fi LP Fuel Level Monitor
6 of 6
G005819-026R Wet Cell Battery
G007101-0Battery Pad Warmer
G007102-0Oil Warmer
G007103-1Breather Warmer
G005621-0
G007027-0 - Bisque
G005703-0 - BisquePaint Kit
G006485-0
G006873-0
Auxiliary Transfer Switch
Contact Kit
Fascia Base Wrap Kit
(Standard on 22 kW)
Scheduled Maintenance Kit
Smart Management Module
(50 Amps)
The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank's fuel level is an important step in making sure your generator is ready to run during an
unexpected power failure. Status alerts are available through a free application to notify when your LP tank
is in need of a refill.
Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet
cell battery for use with all air-cooled standby product (excluding PowerPact®).
The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below
0 °F (-18 °C). (Not necessary for use with AGM-style batteries).
O
il warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below
.
(-18 °C)
0 °F
The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers
only in climates where heavy icing occurs.
The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load
you may not need. Not compatible with 50 amp pre-wired switches.
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a
sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting
holes located in the base.
If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from
future corrosion. The paint kit includes the necessary paint to properly maintain or touch up a generator
enclosure.
Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine
maintenance on a Generac automatic standby generator.
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its
power management capabilities. It provides additional power management flexibility not found in any other
power management system.
727.2 mm
[28.6 in]
Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
637.6 mm
[25.1 in]
648 mm
[25.5 in]
LEFT SIDE VIEW
dimensions & UPCs
1218 mm
[48.0 in]
ModelUPC
G007035-1696471074161
G007036-1696471074154
G007037-1696471074178
G007038-1696471074185
G007039-1696471074192
G007042-2696471074208
G007043-2696471074215
1232 mm
[48.5 in
]
FRONT VIEW
®