STANDBY GENERATOR ACCESSORIES
21 Light Remote Annunciator
Liquid-Cooled Generator Sets
Model 5465
Model 5466
Model 5464
DESCRIPTION
The Remote Annunciator Panel provides remote monitoring and
annunciation of up to 18 generator parameters using LED’s located on
the annunciator keypad. It also provides two system level warnings which
are System Ready and Communications OK.
The Relay panel has up to 8 selectable functions on form A relays,
and multiple relay panels can be connected for all 18 generator
parameters.
The specific faults can be selected using either the DIP switches located
on the annunciator circuit board or through a computer via the RS232
connection on the circuit board. All relays are energized on power up and
open during a fault condition.
Communication is via a RS485 serial data link and power is supplied by
the generator battery (+12 VDC or +24 VDC)
Note: These units are only compatible with the H-series generator
controller (70-150 kW)
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature .......................................................................................................................................................................... -25 º C to 60 º C
Humidity ............................................................................................................................................................................... 0 to 95% Non-Condensing
Power Supply ..........................................................................................................................................................................................+12 or +24 VDC
Power Usage ............................................................................................................................................................................................ 6 Watts typical
Power Supply .......................................................................................................................................................................................Generator Battery
Communication Line .......................................................................................................................... RS485 fully isolated twisted pair cable with shield
Maximum Cable Length .................................................................................................................................................................................... 4000 feet
Relay Output .............................................................................One NO contact (Engergized when annunciator is powered and no faults are present)
Relay Contact Rating .............................................................................................................................................................................. 30 VDC, 1 amp
21 Light Remote Annunciator
5.8
4.530.812 Dia.
0.812 Dia.
Both sides
0.86
9.06 1.64
2.32
6.49
11.42
8.27
9.64
Outside
Cut
Rough Opening
6.75 " x 9.88 "
Four mounting holes for
21 Light Annunciator
4-mm -0.7 Female Thread
1.57
Thru
R0.59
Both Sides
1.93
10.24
7.09
1.21
1.42
0.87
Specifications
Function Color Alarm Latched
Pre-Low Oil Pressure Yellow
Pre-High Water Temp Yellow
Pre Low Water Temp Yellow
Pre-Low Fuel Yellow
Battery Charge AC Fail Yellow
Low Battery Voltage Yellow
High Battery Voltage Yellow
Not in Auto Red
RPM Sensor Loss Red
Overcrank Red
Overspeed Red
Low Oil Pressure Red
Hi Water Temp Red
Low Water Level Red
Emergency Stop Red
Gen Running Yellow
Gen Power (ATS) Yellow
Line Power (ATS) Green
Systems Ready Green
Communications OK Green
Spare Green
n
Yes Yes
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Yes Yes
Yes Yes
Yes Yes
Yes No
Yes No
No No
Yes No
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes No
No No
No No
No No
Yes No
Yes No
No No
Spare Keypad Switch - Can be used to implement a remote start function. (Model 5464 only)
Surface Mount Annunciator
The 21-Light Annunciator can mount to
a flat surface with connections through
the 0.812 Dia. knockout on the back
surface or through 0.812 knockouts on
sides as shown.
Generac Power Systems, Inc. • P.O. Box 297, Whitewater, WI 53190 • guardiangenerators.com
©2008 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0177350SBY/Printed in U.S.A. 04.08, rev. 05.08
Flush Mount Annunciator
This Flush Mount Box is recessed
into the wall opening and the surface mount annunciator mounts to
the (4) 4 mm screw holes on the
back surface. After wire connections are made the front annunciator cover is attached.