GE Industrial Solutions AMCB4EY, AMCB6EY User Manual

g
p
g
quip
y
DEH062 Installation Instructions R02
Spectra Series™ Power Panelboards
Bolt-On Circuit Breaker Kits
Application
These instructions apply to bolt-on circuit breaker kits with catalog numbers AMCB6EY and AMCB4EY.
For use with circuit breaker type TEY.
For use with circuit breaker cover kit AFP3EYD.
WARNING: Danger of electrical shock or injury.
OFF
Turn switchboard before workin e Equipment is to be installed and maintained b properly trained and qualified personnel only.
In the following instructions, numbers in brackets in the text and figures refer to the items in Table 1.
1. Confirm the contents of the kit. These kits are used to install TEY circuit breakers into Spectra APNB bolt­on–style interiors. The parts included in these kits are listed in Table 1.
Item Description
1 A pole strap assembly 1 1
Carriage bolt,
2
Carriage bolt, 3 Conical spring washer, 1/4"2 3 4 Nut, 1/4-20 2 3 5 B pole strap assembly 1 1 6 C pole strap assembly 1 1 7 Lower mounting bracket 2 2 8 Thread-forming screw 4 4 9 Upper mounting bracket 2 2
10 Screw with lockwasher,
#8-32 x 11 B-phase isolator 1 1 12 Antiturn clips 2 3
* For use with a vertical bus rated at 600 A or less.
Table 1. Parts included in kits AMCB4EY and AMCB6EY.
2. Locate the side of the interior with a 2.75-inch
reference distance. The circuit breaker straps are
mounted on the side of the panel interior bus at which the distance from the nearest vertical bus face to the inner face of the bus-support rail is 2.75 inches, as indicated in Figure 2.
ower ahead of the panelboard or
inside the
ment or removing any component.
1 1
1
/4"
/4-20 x 11/2" /4-20 x 1" *
Qty. in
AMCB4EY
23
44
Qty. in
AMCB6EY
3. Install the circuit breaker straps. For three-phase applications (kit AMCB6EY), install the straps beginning with the pole farthest from the 2.75-inch dimension, as shown in Figures 1 and 2. Slide an antiturn clip [12] over the square shank of a carriage bolt [2], then insert the bolt assembly into the A phase bus, with the head opposite the 2.75-inch dimension. Position the square hole of the A pole strap [1] onto the bolt, with the pin of the antiturn bracket inserted into the small hole in the strap. Secure with a conical spring washer [3] and nut [4], leaving the connection finger tight. Repeat the process for the B pole strap [5] and C pole strap [6].
For single-phase panels, dc applications, and phase­balancing purposes (kit AMCB4EY), Table 2 lists the possible configurations. Align the appropriate strap assemblies [1, 5, 6] with the corresponding holes in the vertical bus, as shown in Figures 1 and 2. Fasten each strap assembly loosely to the vertical bus with a carriage bolt [2], conical washer [3], and nut [4], as described for the three-phase kit. When installing any of the two-pole strap configurations in Table 2, be sure to install the straps in standard phase-rotation order. When installing a two-pole and a three-pole breaker in a double-branch assembly, arrange the straps in the typical three-pole configuration, as shown in Figure 2.
Application A Phase B Phase C Phase
X
Single pole
XX
Two pole
* Use for single-phase panels and dc applications.
Table 2. Possible pole configurations with kit AMCB4EY.
4. Install the lower circuit breaker mounting brackets and cover supports. Attach the lower breaker
mounting brackets [7] to the panel side rails with the thread-forming screws [8], as shown in Figure 1. Tighten the screws to 35 in-lb. Slide the cover supports (included in the breaker cover kit), with the mounting tabs oriented inward, onto each bracket until they snap into place, as shown in Figure 1. Use the uppermost slot on the cover support body. Cover supports can be easily removed by inserting a screwdriver blade into the slot on the underside of the mounting bracket assembly and gently prying downward while pushing the support off.
X* X*
X
X
XX
Figure 1. Mounting TEY circuit breakers into Spectra APNB bolt-on interiors.
Strap Mounting Side
Cover
Support
on Main Busbar
Cover
Support
Figure 2. Mounting TEY circuit breakers into Spectra APNB bolt-on interiors, assembly end view.
Loading...