Product Technical Information
December 11, 2020
Data shown is for the current revision model #. Ensure your nameplate model # matches.
Model Number: |
5KS509DAJ6030A |
Catalog Number: |
V955 |
|
|
Instruction Manual: |
GEI-M1045 |
Connection Diagram: |
GEM2034E-FIG19 |
Outline Drawing: |
148CB59VMKKFGAA0001 |
|
|
Accessory Connection Diagrams
Bearing Thermocouple: |
None |
Heater: |
3027JE-1C |
RTD: |
None |
Thermistor: |
None |
Thermostat: |
None |
Winding Thermocouple: |
None |
Bearing RTD: |
None |
|
|
Table of Contents
Specification |
01 |
Performance Characteristics |
02 |
Outline Drawing |
03 |
Connection Drawing(s) |
04 |
Model Number:5KS509DAJ6030A |
|
|
December 11, 2020 |
||
|
Marks: |
|
|
|
|
|
|
|
|
|
|
|
MODEL NUMBER: |
5KS509DAJ6030A |
Estimated Weight: |
4173 Lbs |
|
|
Outline Drawing: |
148CB59VMKKFGAA0001 |
Time Rating: |
CONT |
|
|
|
|
|
|
|
|
Connection Diagram: |
GEM2034E-FIG19 |
Enclosure: |
WPI |
|
|
Instruction Book: |
GEI-M1045 |
Encl Construction: |
OPEN |
|
|
Design Code: |
50ED1309AA |
Ambient Max(°C): |
40 |
|
|
Type: |
KS |
Alt Ambient Max(°C): |
-- |
|
|
Frame: |
B509TP24 |
Insulation Class: |
F |
|
|
Phases: |
3 |
NEMA Design: |
B |
|
|
Poles: |
4 |
Nominal Efficiency: |
96.2 % |
|
|
Output Power: |
500HP 370KW |
Guaranteed Efficiency: |
95.4 % |
|
|
RPM: |
1785 |
3/4 Load Efficiency: |
-- |
|
|
Voltage: |
460 |
KVA Code: |
G |
|
|
Hertz: |
60 |
Max KVAR: |
91.6 |
|
|
|
|
|
|
|
|
Amps - FL: |
547.0 |
Power Factor: |
89.0 |
|
|
Service Factor: |
1.15 |
Bearing - DE: |
6219ZC3 |
|
|
Alt Service Factor: |
-- |
Bearing - ODE: |
29430 |
|
|
|
|
|
|
|
Enclosure is Weather Protected One
Stamped Nameplate Notes:
NEMA ENCLOSURE WP-I, CSA ENCL DP THERMOSTAT LEADS TB1-TB2:TRIP HTR LDS HE1-HE2 115V 350W
UPPER BRG LUBE OIL: 12.68 QTS
6 DEG C TO 40 DEG C :ISO 150(MINERAL OR SYNTHETIC)
-15 DEG C TO 5 DEG C : ISO 68 SYNTHETIC LOWER BRG LUBE OIL: 2.5 QTS
0 DEG C TO 40 DEG C :ISO 32(MINERAL OR SYNTHETIC)
-15 DEG C TO 0 DEG C : ISO 32 SYNTHETIC
ROT CCW FACING TOP LEAD/PH SEQ 1-2-3/1-2-3 5600 LBS MIN CONTINUOUS DOWNTHRUST REQ"D STAMP NP249A5564P009 AS FOLLOWS: REQUIRED COOLING WATER:2.0 GPM
MAXIMUM COOLING WATER:3.5 GPM MAXIMUM PRESSURE:100 PSI
MAXIMUM WATER INLET TEMP :95 DEG F INVERTER DUTY PER NEMA MG1 PART 31 ALTERNATE RATING FOR PWM CONTROL
Page | 1