Product Technical Information
October 23, 2020
Data shown is for the current revision model #. Ensure your nameplate model # matches.
Model Number: |
5KS509XAA124D |
Catalog Number: |
Q815 |
|
|
Instruction Manual: |
GEI-56128 |
Connection Diagram: |
GEM2034E-FIG20 |
Outline Drawing: |
239C6A00JB |
|
|
Accessory Connection Diagrams
Bearing Thermocouple: |
None |
Heater: |
3027JE-1C |
RTD: |
235A3027XY |
Thermistor: |
None |
Thermostat: |
None |
Winding Thermocouple: |
None |
Bearing RTD: |
235A3027NA |
|
|
Table of Contents
Specification |
01 |
Performance Characteristics |
02 |
Outline Drawing |
03 |
Connection Drawing(s) |
04 |
Spare parts |
05 |
Model Number:5KS509XAA124D |
|
|
October 23, 2020 |
||
|
Marks: |
|
|
|
|
|
|
|
|
|
|
|
MODEL NUMBER: |
5KS509XAA124D |
Estimated Weight: |
4563 Lbs |
|
|
Outline Drawing: |
239C6A00JB |
Time Rating: |
CONT |
|
|
|
|
|
|
|
|
Connection Diagram: |
GEM2034E-FIG20 |
Enclosure: |
TEFC |
|
|
Instruction Book: |
GEI-56128 |
Encl Construction: |
841 |
|
|
Design Code: |
50BD0233B |
Ambient Max(°C): |
40 |
|
|
Type: |
KS |
Alt Ambient Max(°C): |
-- |
|
|
Frame: |
509LS |
Insulation Class: |
F |
|
|
Phases: |
3 |
NEMA Design: |
B |
|
|
Poles: |
2 |
Nominal Efficiency: |
95.8 % |
|
|
Output Power: |
300HP 222KW |
Guaranteed Efficiency: |
95.0 % |
|
|
RPM: |
3560 |
3/4 Load Efficiency: |
-- |
|
|
Voltage: |
575 |
KVA Code: |
G |
|
|
Hertz: |
60 |
Max KVAR: |
40.5 |
|
|
|
|
|
|
|
|
Amps - FL: |
251.0 |
Power Factor: |
93.5 |
|
|
Service Factor: |
1.15 |
Bearing - DE: |
6315ZC3 |
|
|
Alt Service Factor: |
-- |
Bearing - ODE: |
6315ZC3 |
|
|
|
|
|
|
|
Enclosure is Totally Enclosed Fan-Cooled
Stamped Nameplate Notes:
EXCEPTION TO IEEE-STD-841-2009: SOUND POWER 92 DBA TEMP CONT HTR LDS HE1-HE2 115V 200W
DE BRG 75BC03XP3, ODE BRG 75BC03XP3
ROT CW FACING ODE LEAD/PH SEQUENCE 1-2-3/1-2-3 MAX SPACE HEATER SURFACE TEMPERATURE 160C STAMP NP249A5564P075 AS BELOW: MODEL:5KS509XAA124D
SN: XXX CSA CERTIFIED CSA.09.2216219
FOR CL I DIV2 GRP A,B,C,D T3 IN -25C<= TAMB<= 40C 1.0SF ON SINE-WAVE PWR OR ALTERNATE RATING TEMP CODE T2D AT 1.15 SF ON SINE-WAVE PWR
OR -- VT PWM CONTROL 1.0 SF -- C AMB VT -- HZ. FOR DIRECT COUPLED LOAD ONLY
Page | 1
Model Number:5KS509XAA124D |
October 23, 2020 |
Additional Information:
2P - LS EXTN - SPLIT LEAD PAINTED FRAME ID & SHAFT,
FAN COVER INSIDE & ODE E/S OUTSIDE C/BOX 1260 CU IN - 2(4.00" NPT)
C/B GRD PLATE
INPRO SEAL BOTH ENDS
OIL RESISTANT SLEEVING ON LEADS
.0015" TIR SHAFT RUNOUT
ROUTINE TEST REPORT AND 5 POINT VIBRATION TEST REPORT INCLUDED IN C/B
COPPER WASHER UNDER HEADS OF BEARING CAP BOLTS, APPLY TITE-SEAL (A50CD427A) ON BEARING CAP SCREWS, RABBETS AND PLUG THREADS.
100 0HM WINDING RTD LEADS TO AUX BOX W/TERM BOARD OPP C/BOX SUGGESTED WINDING RTD SETTINGS
ALARM 165C TRIP 175C
115V TSTAT CTRLD HTR LDS TO AUX BOX W/ TERM BOARD OPP C BOX SPACE HEATER CAUTION NAMEPLATE
BEARING RTD 100 OHM ON BOTH ENDS
SUGGESTED BEARING RTD SETTINGS ALARM 115C TRIP 125C
NEMA TYPE GRD PAD F1 MOUNTING
I-ALERT MOUNTED ON DE ENDSHIELD
Page | 2