• Proper installation is the responsibility
of the installer. Product failure due to improper
installation is not covered under the warranty. See
Owner’s Manual for warranty information.
• Use this appliance only for its intended purpose.
•
Check with local utilities for electrical codes that
apply in your area. Local codes vary. Installation
electrical connections and grounding must
comply with applicable codes. In the absence
of local codes, the drawer should be installed
in accordance with National Electrical Code ANSI/
NFPA 70-1990 or latest edition.
WARNING
This appliance must be properly grounded.
See “Grounding the Appliance.”
For Monogram local service in your area,
1.800.444.1845.
For Monogram Service in Canada,
call 1.800.561.3344.
For Monogram Parts and Accessories,
call 1.800.626.2002.
If you received a damaged warming drawer,
you should contact your de a l e r.
WARNING
An anti-tip brace must be installed to prevent
the drawer from tipping forward when opened
and loaded. Failure to do so could result in
personal injury.
2
CONTENTS
Design Information
Design Information
Models Available ......................................................................3
This kit provides for the installation of a custom
front panel on 27” and 30” models.
NOTE: The original drawer front will be removed
and discarded when this kit is used. The tubular
handle can be reinstalled onto the custom panel
with longer screws (not provided). Or, the original
handle can be replaced with a custom handle of
your choice. (Handle is not supplied.) Choose a
custom handle to match or complement cabinetry
hardware.
ZXD30P:
This kit provides for the installation of a stainless
steel professional style door with handle for 30”
models.
NOTE: The ZXD30P professional drawer panel with
handle is a one-piece assembly that replaces the
original drawer front and tubular handle. The original
tubular handle (or a custom handle) cannot be
installed onto this professional drawer panel.This
ZXD30P accessory is designed to fit 30” warming
drawers manufactured after February 2006.
3
Design Information
PRODUCT DIMENSIONS AND CLEARANCES
A
Drawer
Open
1”
A B C
ZTD910 22” 26” 30”
ZTD910 w/ZXD30P 23-1/4” 27-1/2” 30”
ZKD910 22”26” 26-3/4”
23-1/4”
B
Including
Handle
Dimensions
ADVANCE PLANNING
• The drawer may be installed below a countertop, a
cooktop, a single or double oven and side by side using 2
drawers.
• The warming drawer can be installed below approved
cooktops. Allow 2” min. clearance from bottom of cooktop
burner box to top of warming drawer cutout. See page 8.
• The warming drawer can be installed below approved
ovens. Allow a 2” min. clearance between cutouts.
Additional clearances may be required. See page 7.
9”
C
10-1/2”
• Electrical power cord is located on the right side of the
warming oven. Locate the outlet within reach of the 56”
long power cord in an adjacent cabinet, within 42” of the
right side or 16” from the left side of the cutout. A recessed
receptacle can be installed on the right side of the cutout,
7” max. from the rear of cabinet.
4
Design Information
GROUNDING THE APPLIANCE
Please read carefully.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY
GROUNDED.
Do not use an extension cord or adapter plug with this
appliance. Follow National electrical codes or prevailing
local codes and ordinances.
This warming drawer must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded branch
circuit, and protected by a 15 or 20 amp circuit breaker or
time delay fuse.
Please read carefully.
The power cord of this appliance is equipped with a 3-prong
(grounding) plug that mates with a standard 3-prong
grounding wall receptacle to minimize the possibility
of electric shock. The customer should have the wall
Rating Plate
• A properly grounded 3-prong receptacle should be located
within reach of the drawers’ 56” long power cord.
• Locate the receptacle in an adjacent cabinet.
– within 42” of the right side or,
– within 16” of the left side or,
– A recessed receptacle may be located on the right side
of the cutout, 7” from the back of the cabinet. In this
location, the excess power cord should be coiled and
taped to the right side of the unit.
• When two warming drawers are installed side to side, they
can operate from the same receptacle.
receptacle and circuit checked by a qualified electrician to
make sure the receptacle is properly grounded and has the
correct polarity.
• Where a standard 2-prong wall receptacle is encountered,
it is the personal responsibility and obligation of the
customer to have it replaced with a properly grounded
3-prong wall receptacle.
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.
Recessed
Receptacle
7” Max. From
Rear on Right
Side
Drill 1-1/2” Hole
For Power Cord
For Left or Right
Side Outlet
Location