ZGU486NDPSS (Natural Gas)
Controll panel projects forward from standard depth cabinets.
Front of deep cabinets can align with control panel beveled edge.
ZGU486LDPSS (Liquid Propane)
GE Monogram® 48" Professional Gas Rangetop with 6 Burners and Griddle
Dimensions and Installation Information
Professional rangetops offer a number of choices in size and rangetop configurations.
Product Dimensions and Clearance
A 48"- or 54"-wide professional vent hood with a minimum 1200 CFM is recommended for installation over this rangetop.
Clearances between rangetop and side wall or combustible material must be at least 12" on each side.
* The opening between a 4" high backsplash must be 36" to allow the rangetop to slide back against the wall.
WARNING: Installations without a hood require 48" mini­mum to combustibles above the rangetop. A custom hood installation with exposed horizontal combustible surfaces must have an "auto-on" feature. Refer to hood installation instructions for specific hood clearances. The surface of the entire back wall above the countertop and below the hood must be covered with a non-combustible material such as metal, ceramic tile, brick, marble or other stone.
Allow 8" free space below the top surface of countertop. Allow additional clearances below the burner box to install the regulator and make house gas supply connections. Use a 90° elbow to route the gas connections and limit interference with drawers or other cabinetry.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Specification Created 7/08
130453
ZGU486NDPSS (Natural Gas) ZGU486LDPSS (Liquid Propane)
GE Monogram® 48" Professional Gas Rangetop with 6 Burners and Griddle
Dimensions and Installation Information
Backsplash Accessories
The rangetop requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non-combustible backsplash can be used.
ZX12B48PSS, 12" backsplash ZXADJB48PSS, 30"-36" adjustable-height backsplash with
warming shelf
Side View with a Backsplash
Advance Planning for 48" Professional Rangetops
Professional rangetops offer a number of choices in size and rangetop configurations.
• All Professional rangetops are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation.
Note: Conversion kits are included with the rangetop if the wrong gas type was ordered. High Altitude kit, WB28K10553, is also available. The kits must be installed by a qualified service technician at additional cost.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Electrical Requirements
Rangetops must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a 15 amp circuit breaker or time-delay fuse.
Gas Supply
• Natural gas models are designed to operate at 5" water column pressure. For proper operation, the pressure of the natural gas supplied to the regulator must be between 7” and 13” water column.
• The liquid propane models are designed to operate at 10" water column pressure. For proper operation, the pressure of the LP source to the regulator must be between 11” and 13” water column.
Specification Created 7/08