WALLIGHTER 400 LUMINAIRE
APPLICATIONS
• Underpasses, loading docks and building perimeter security
• Applications where a high wattage wall mounted luminaire is needed
SPECIFICATION FEATURES
• / 1598 Listed
Suitable For Wet Locations
• Sealed and charcoal ltered housing
• Die-cast aluminum housing protected
inside and out with dark bronze polyester
powder paint nish
• ALGLAS® nish on aluminum reector
• Heat and impact resistant prismatic
glass refractor
ORDERING NUMBER LOGIC
• Pre-wired terminal board and
integral direct-mounted ballast
• .75 in. (19mm) NPT conduit
entrances sides and top
• Photoelectric receptacle available
• Mogul base E39 socket standard
except 150W PMH medium base socket
• Magnapack packaging available
The Energy Independence and Security Act of 2007 (EISA) aects Metal Halide (MH) and Pulse Metal Halide
(PMH) wattages from 175W to 450W and for domestic usage, the new digit is “E = EISA-compliant PMH” which
has a minimum eciency of 88%. In many cases, the lumen value and lamp life of a lesser wattage meets or
exceeds the former MH ballast/lamp system. For 175W applications, where 175W E-PMH is not available, 150W
PMH may be an acceptable substitute. 150W PMH is medium base socket unless otherwise listed or requested.
PRODUCT
IDENT
XXX
W4L =
Wallighter 400
WATTAGE
XX
15 = 150
17 = 175
20 = 200
25 = 250
32 =320
35 = 350
40 = 400
LIGHT
SOURCE
X
Energy
E =
Act Compliant Pulse
MH (EPMH)
S = HPS
M = MH
P = PMH
Standard:
Lamp not
included.
VOLTAGE
X
60Hz
0 = 120/208/
240/277
Multivolt
1 = 120
2 = 208
3 = 240
4 = 277
5 = 480
C = 120/240/
277
D = 347
T = 220
50Hz
6 = 220
Y = 240
BALLAST
TYPE
X
See Ballast and
Photometric
Selection Table
A = Autoreg
G = Mag-
Reg with
Grounded
Socket Shell
H = HPF Reactor
or Lag
K = Hot Restart
M = Mag-Reg
N = NPF Reactor
or Lag
P = CWI with
Grounded
Socket Shell
PE
FUNCTION
X
1 = None
2 = PE Receptacle
NOTE: Receptacle
connected same
voltage as unit.
Vertical mounting
only. Order PE
Control separately.
IES DISTRIBUTION
TYPE
XXX
See Ballast
and Photometric Selection
Table
SN4 = Short, Non-cuto,
Type IV
COLOR
XX
DB = Dark
Bronze
OPTIONS
XXX
B = Time Delay
Automatically Switched
Quartz
F = Fusing (Not
available with
multivolt)
L = Latch on door
S = External
Sliptter for
1-1/4 inch
(32mm)
diameter Pipe
Mounting
Ø48=External
Sliptter for
2 in. (51mm)
diameter pipe
mounting
A-82/2008
GE Lighting Systems, Inc.
www.gelightingsystems.com
FIXTURE DIMENSIONS
WALLIGHTER 400 LUMINAIRE
DATA
Approximate Net Weight 27-45 lbs 12-20 kgs
Eective Projected Area 1.5 sq ft max 0.15 sq M max
BALLAST AND PHOTOMETRIC SELECTION TABLE
All light sources are clear unless otherwise indicated.
Ballast Type/Voltage
IES
Light Multi- 120, 208, Distribution
Wattage Source volt 240, 277 347 480 220 220 240 Type
150 (55V) HPS H,N G,H,K,M,N H,M,N M N/A N/A H,M SN4 9714
200, 250,
400 HPS A A,P A, P A,P A A A SN4 9664
150 PMH H* H H N/A N/A N/A N/A CF CF
250,320 EPMH A A N/A N/A N/A SN4 9713
350, 400 EPMH A A
CANADA & EXPORT ONLY
175, 250
MH A A A A A A A SN4 9713
400 MH A A, P A, P
NOTE: N/A = Not Available.
CF = Contact Factory.
* = 120X240X277
60Hz 50Hz
A
N/A N/A N/A SN4 9665
A,P
N/A CF CF SN4 9665
Photometric
Curve
Number
35-17 - - - -
REFERENCES
See Page A-97 for start of Accessories.
See Page A-101 for Explanation of Options and Other Terms Used.
GE Lighting Systems, Inc.
www.gelightingsystems.com
2008/A-83