This 42" stainless steel
island hood has a fourspeed dual blower fan
that operates at a
maximum venting power
of 1080 CFM. Use duct
cover accessories to
reach ceiling heights up to 10 ft.
The New Line of Professional
Hoods Offer Three Distinctly
Different Styles
Choose straight sided, taper-sided or the dramatic
Restaurant-Style Hood.
ZV48TSFSS
ZV36TZV36SZV36RZVB36
ZV48TZV48SZV48R
IncludedRemote Blower
A complete line of Monogram hoods.
and Ranges
Products
Refrigeration
Professional
Cooking Products
Warming Drawers
Ovens, Microwave
Cooking Surfaces
ZV48SSFSS
IncludedRequired9' or 10'6" and 12" Duct Covers - StackableOptions
ZV48RSFSS
OptionalOptional
Included
10' Ceiling10' to 14'Must OrderDuct Cover
Duct CoverDuct CoverSeparatelyOptional
These new Monogram® Professional Hoods are available
in 48", 36" and 30" widths. All with four speed blower fan,
halogen lights and infrared warming lights.
Select a hood to match the width of cooktop or range.
48" Wide Model36" Wide Model
Diagram 11Diagram 12
ZV48RSFSS ZV36RSFSS
30" Wide Model
Diagram 13
ZV30RSFSS
12"
35-15/16"
22-1/2"
35-15/16"
25"
Blower outlet is 8-1/8" x 8"
Includes a transition for 10" round.
Determine Installation Height
Installation
Height
Dim. A
Refrigeration
10"
Professional
Ovens, Microwave
Products
Cooking Products
Warming Drawers
Cooking Surfaces
Venting Systems
30" Min.
36" Max.
32" Min.
38" Max.
Diagram 14
Determine bottom of hood location (Dimension A) by
subtracting 12-1/2" from the desired installation height.
IMPORTANT:
“Using Duct Cover Accessories”, page 99. Exact installation height may be
Diagram 9
Installation without Warming Shelf
Install these hoods 30" min. to 36"
max. above the cooking surface of
any professional style range or
cooktop.
These hoods may be installed 24" min. above a gas or electric drop-in style
cooktop.
9697
Installation with Warming Shelf
Install these vent hoods 32" min. to 38"
max. above any type cooking surface
when warming shelf if used.
Diagram 10
determined by use of one or more duct covers.
If you are installing the hood with duct covers, be sure to read
Dishwashers, Chef’s
Washers, Compactors
Outdoor
Cooking Centers
Advance Planning for
6" Duct Cover
12" Duct Cover
Ceiling Height
A
C
B
10"
Hood
Height
All Professional Vent Hoods
• Select a straight, tapered or restaurant-style hood to match
the width of the range or cooktop.
• All models can be installed onto a wall or beneath a soffit.
Duct covers are available to conceal the ductwork (at extra
cost). Duct covers are available in 6" to 12" heights. They can
be stacked in various combinations to reach ceiling heights.
• To avoid unsightly gaps, plan the hood installation height
with consideration to duct cover use. See the opposite page
to determine the need for one or more 6" or 12" duct covers.
Adequate Structural Support
• All Professional Hoods weigh over 100 pounds. Therefore,
adequate structural support must be provided. Hoods must
be secured to vertical studs or to studs in the soffit.
• It is strongly recommended that the vent hood and duct
cover(s) if used, be on site before final framing and wall
finishing. This will help to accurately locate the ductwork and
electrical service.
• Final installation will be much easier if the hood is installed
before the range or cooktop below.
Accessory Duct Covers
• Decorative duct covers are designed to complement all
Professional Hoods. Available in 6" and 12" heights. Duct
covers may be stacked, in various combinations to conceal
the ductwork running from the top of the hood.
Diagram 15
6" Duct Covers
Hoods6" Duct CoverDimensions
ZV48ZX48DC66"H x 19-11/16"W x 11-7/8"D
ZV36, ZV30ZX36DC66"H x 15-3/4"W x 11-7/8"D
12" Duct Covers
Hoods12" Duct CoverDimensions
ZV48ZX48DC1212"H x 19-11/16"W x 11-7/8"D
ZV36, ZV30ZX36DC1212"H x 15-3/4"W x 11-7/8"D
Using Duct Cover Accessories
Use the following formulas to calculate the need for one or
more duct covers and to ensure a trouble free installation.
Products
Refrigeration
Professional
Cooking Products
Warming Drawers
Ovens, Microwave
Ductwork Planning
• These vent hoods are equipped for 10" round ductwork. In
most instances they may be transitioned to 8" round using
locally supplied transition pieces.
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Always use the shortest and straightest route possible.
• For satisfactory performance, duct run should not exceed
150 feet equivalent length for any duct configuration. Refer
to the Duct Fittings chart in the installation instructions.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition
needed in advance.
Refer to Installation Instructions for details
Pub. No. 49-80151 for Straight and Taper-Sided Professional Hoods
Pub. No. 49-80152 for Restaurant-Style Professional Hoods
98
Straight or Taper-Sided Hoods
Ceiling Height
B
18" Hood
A
C
Note: Dimension C should be between 40" and 46" (for a 30" to 36" installation
height). Raise or lower the hood installation height to allow use of one or
more 6" and 12" duct covers.
A - B = C
A = Countertop to ceiling height.
B = Gap at the top of the hood to
Height
the ceiling.
C = Hood installation height, Plus
18" hood height.
Diagram 16
Restaurant-Style Hoods
A - B = C
A = Countertop to ceiling height.
B = Gap at the top of the hood to
the ceiling.
C = Hood installation height, Plus
10" hood height.
Diagram 17
Note: Dimension C should be between 48" and 54" (for a 30" to 36" installation
height). Raise or lower the hood installation height to allow use of one or
more 6" and 12" duct covers.
99
Cooking Surfaces
Venting Systems
Dishwashers, Chef’s
Washers, Compactors
Outdoor
Cooking Centers
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.