![](/html/de/de21/de2129a426dde3773020b85e79247c419c74c2c4fd09ca4cb122e876233da8a4/bg1.png)
GE
Lighting Solutions
TM
GT1
LED
Pedestrian Signals
16 x 18 inch Side by Side Full Hand, Full Person
Excellent Appearance & Visibility
• Robust LED system design enables high luminous intensity over long product life
• Efficient optical system minimizes power consumption while providing excellent
uniformity and viewing angles
• Single piece transparent front window with internal masking to prevent:
- icons display from being readily visible when not in operation
- scratches and abrasions compared with external silk screen technology
• Bright and clear icons
• New or retrofit use
• Fully uniform look
Outstanding Reliability & Robust Operation
• Internal conflict monitor preventing walk and don’t walk indications to light up
at the same time (PS7-CFC1-26A only)
• Individual power supply drives each display to ensure proper indication
• Over-molded electrical connectors providing moisture and dust protection
Meets Rigorous Certification & Testing Standards
• Intertek ETL Verified compliant (PS7-CFC1-26A only)
• DOE compliant
• Caltrans approved - Draft Specifications dated Dec. 2008 (PS7-CFC1-26A-22 only)
• Using MIL-STD-810F and NEMA 250-1991 Type 4 for environmental robustness,
passed reliability and qualification testing including high temperature,
high humidity cycling (HTHH for 1,000 hours)
• Production quality compliant to GE Six Sigma requirements
• Compliant with the ITE PTCSI LED Signal Modules
- Version dated August 2010 (PS7-CFC1-26A only)
The Greatest Signals Stand the Test of Time
.TM
![](/html/de/de21/de2129a426dde3773020b85e79247c419c74c2c4fd09ca4cb122e876233da8a4/bg2.png)
GT1TM LED Pedestrian Signals
• 16 x 18 inch module
Mechanical Outline
17.7
Dimensions in inches. (mm) indicates metric equivalent
(406)
16.0
Design Compliance
Test type Compliance
A: ITE PTCSI LED Signal Modules
Version dated August 2010
Luminous Intensity
Draft version of Dec. 2008
A: ITE PTCSI LED Signal Modules
Version dated August 2010
Chromaticity
Draft version of Dec. 2008
Blown Wind Rain MIL-STD-810F
Moisture Resistance
Mechanical Vibration MIL-STD-883 Method 2007
Electronic Noise FCC Title 47 Sec 15 Sub. B
A: ITE PTCSI LED Signal Modules
Transient Voltage Protection
B: Caltrans Specifications
Draft version of Dec. 2008 (NEMA 2.1.8.)
Controller Compatibility NEMA TS-2-2003
Wiring NFPA 70, National Electric Code
B: Caltrans Specifications
B: Caltrans Specifications
method 506.4 - NEMA 250 type 4
1
Version dated August 2010 (NEMA 2.1.8.)
3.8
(354)
13.9
Operating Specifications
Parameter Rating
Operating Temperature Range* -40 to +74°C (-40 to +165°F)
Operating Voltage Range 80 to 135 V (60Hz AC)
Power Factor (PF) > 90 %
Total Harmonic Distortion (THD) < 20 %
Voltage Turn-Off (VTO) 35 V
Start-up Time < 75msec
Lens & Shell Material UV Stabilized Polycarbonate
16 AWG, Color Coded
Wiring
with Strain Relief
LED Color
Person: Lunar White
Default Mode Hand only (PS7-CFC1-26A only)
* Performed in compliance with ITE test method described in the technical notes
Hand: Portland Orange
Product Information
50% L.O. Minimum Luminance
Dimensions Symbol AC Voltage Power (W) Beam Angle on Axis Cd/m
Model Number Dimensions Layout Hand Person Nominal Hand Person Degrees Hand Person
2
PS7-CFC1-26A
PS7-CFC1-26A-22
1
Class A
2
ITE PTCSI LED Signal Modules - version of August 2010
3
Caltrans Specifications - Draft version of Dec. 2008
Test Condition: Ta = 25ºC. All values are design or typical values when measured under laboratory conditions.
16 x 18 in Side by Side Full Full 120V - 60Hz 5 5 26 1400 2200
3
16 x 18 in Side by Side Full Full 120V - 60Hz 6 6 18 3750 5300
Distributed by:
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. GT1 and “The Greatest Signals Stand the Test of Time” are trademarks of GE Lighting Solutions, LLC. The GE brand and logo are trademarks
of the General Electric Company. © 2013 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
TRAF013-R050913
2