Flitmate
340kW Diesel Power Generator
Technical Specifi cations Guide
Products that show their best advantage when mine conditions are most diffi cult.

Flitmate
340kW Diesel Power Generator
The Industrea Mining Equipment
Flitmate Diesel Power Generator 
provides a consistent reliable 
power source for all your 
high powered equipment 
relocation requirements.
Basic Features
■ Trailer mounted 3 Phase generating set 
■ Diesel driven synchronous alternator through a reduction gearbox 
■ Designed to provide the power to ‘fl it’ or ‘tram’ 1000V powered underground mining machines. 
■ Braked trailer with retractable wheel units & stab jack 
■ 340kW (320kW Continuous) of electrical power at 1000 volts 
■ Fully fi re-protected Diesel Engine System to ASNZS 3584.1 
■ Electrical systems fully compliant to ASNZS 4871.1 
■ Braked trailer with retractable wheel units & stab jack 
■ Very low emissions 
■ Electronic, digital, engine control and protection system 
■ Catalytic Oxidiser 
■ Optional SCR - Selective Catalytic Reducer 
■ Water based Conditioner reduces smoke 
■ Partcile fi lter removes remaining smoke 
Dimensions
Gross Mass:  13,000kg 
Length:  7100mm 
Width:  2280mm 
Height:  1750mm 

Installed Tier 3 Diesel Engine System.
DIESEL ENGINE SYSTEM
ASNZS 3584.1 compliant 
Cat® C-15E DI TA SC 
Rated 372kW ± 3% @2070rpm 
Tier/Stage 3 compliant 
750rpm (low idle) 2070 rpm (gov) Turbo-charged
SCAC charge cooling 
Engine emergency stop system 
‘Dry’ inlet fi lter 
MANAGEMENT & PROTECTION
CAN-Bus system SAEJ1939 
iGuard programmable monitoring 
EXHAUST SYSTEMS 
Catalytic Oxidiser (DOC) 
Selective Catalytic Reducer (option) 
‘Wet’ Conditioner/cooler 
Particulate fi lter (DPM) 
COOLING
Cross-fl ow, fully tinned Radiator 
‘Multi-wing’ fan 
2 x ‘Header’ Tanks 
GEARBOX
Ratio – 2070-1500 rpm (1.38:1) 
Torque >7200 Nm 
Power > 372 kW 
TRAILER BRAKES
Multi-plate, totally enclosed, oil immersed. 
TYRES & RIMS
Rims, 2 piece, 10 M22 studs 
Tyres, 9.0 X 20, Solid-fi lled 
HYDRAULIC SYSTEM
Fully retractable wheel units 
Front ‘stab’ jack 
Load-lock valves – all functions 
FIRE SYSTEM
Automatic & manually operated system fi tted. 
Fire extinguisher fi tted 
ELECTRICAL SYSTEM (1000V)
ASNZS 4871.1 – 2 (as applicable) 
Fault level >7.3 kA (1 sec) 
Earth fault limit 5A (resistive) 
Main Circuit Breaker (MCCB) >10kA 
Main Contactors – vacuum, reversing 
MANAGEMENT & PROTECTION
Functions
Earth leakage – lockout 
Back-up earth leakage – star Alternator 
Contactor freeze-in 
Alternator thermistors 
Under-frequency 
Over-voltage 
Earth continuity (3) 
Flag & Light indication 
Metering
Ammeter 
Power 
Volts 
Hz 
ALTERNATOR
Rated 450kW (563 KVA) 
1000V 50Hz ±0.5% 
Sustained short circuit 250% (10s) 
2 bearing, B10 40,000hrs 
IP65 (as installed) 
AVR – Digital micro-processor 
AUTO-ELECTRICAL
24V DC system 
Ex.d MCB, nv trip 
24V LA start battery system 
In-built charging system (240V AC) 
Machine lighting 
COOLING RETICULATION
Water cooling for remote powered machines. 
1000 ltr / hr at 20m (head) 
METHANOMETER
Automatic Methanometer fi tted 
Prevents start on high methane 
Stops engine, shuts off power on high methane. 
Products that show their best advantage when mine conditions are most diffi cult.

www.industrea.com.au
Industrea Mining Equipment
63 Bonville Avenue 
Thornton, New South Wales 
Australia, 2322
t  +61 2 4014 8500 
f  +61 2 4014 8599 