8V to 16V AC
8V to 20V DC
Nominal Power Consumption:
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Prepare Electrical Wiring
Electrical Requirements
Do not use in wet locations
Follow all National Electric Codes
(NEC) and local codes.
WARNING / AVERTISSEMENT
Risk of Electric Shock. Disconnect Before Servicing or installing product.
Risque de choc électrique. Couper l’alimentation avant le dépannage ou avant
l’installation du produit.
RG6 LED Signals – 12’’ (300mm) – Railway Grade Crossing
Operating Specifications:
Installation Instructions
Always use a sun shielding apparatus such as a visor or hood over the signals.
Do not attempt to open the LED module. No assembly is required.
Testing:
When testing the lamp before installation, first check the electrical characteristics on the label on the back of the lamp
(see box “B” below) to avoid damaging the lamp.
Installation Steps:
NOTE: Failure to properly follow these instructions may cause signal to malfunction.
1. Remove the incandescent bulb, reflector and lens assembly from the housing.
2. Feed wires of the LED signal module through the conduit in the housing.
3. Insert the LED signal into the lens slot and rotate it until the arrow on the back of the module (A) is aligned with the
top of the housing.
4. Lock the LED signal module in place by tightening metal tabs over the rim of the module, or fastening a ring holder
over the module, as applicable.
5. Connect the wires to the AAR terminals.
…Page 2
NOTE: If you prefer to have this Installation
Instructions document in other languages, visit our
official website at: www.gelighting.com/installation
Check label for required
voltage
Ensure arrow ‘’’’ points
upward for proper beam
alignment
Risk of Electric Shock
Install unit in enclosure tested
to be suitable for wet locations
only.
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3 • or • +1.216.266.2419
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand and logo are trademarks of the General Electric Company.
© 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory
conditions.
RAIL053- R130816
Installation Instructions (cont’d)
RG6 LED Signals – 12’’ (300mm) – Railway Grade Crossing
This product is intended solely for the use of rail signaling and is not intended for use in any other applications