JTS5000DN/BN/EN/FN/SN
Cutout width
28-1/2" MIN.
28-5/8" MAX.
A
C
Cutout height
27-1/4" MIN.
27-5/16" MAX.
Recommended
cutout location
from the floor
32-1/2"
30''
JTS3000DNBB, JTS3000DNWW, JTS3000ENES,
JTS3000SNSS, JTS5000BNTS, JTS5000DNBB,
JTS5000DNWW, JTS5000ENES, JTS5000FNDS,
JTS5000SNSS, PTS7000BNTS, PTS7000FNDS,
PTS7000SNSS, PTS700LSNSS, PTS700RSNSS
Cutout width
28-1/2" MIN.
28-5/8" MAX.
B
A
C
Cutout height
27-1/4" MIN.
27-5/16" MAX.
Recommended
cutout location
from the floor
32-1/2"
Cabinet 30"
A - Overlap of oven at top of cutout 1"
B - Overlap of oven other side of edge of cutout 3/4"
C - Overlap of oven at bottom of cutout 1-1/4"
Oven
D - Install depth 23-1/2"
E - Overall height with trim 28-5/8"
F - Overall width 29-3/4"
Cutout width
28-1/2" MIN.
28-5/8" MAX.
B
A
C
Cutout height
27-1/4" MIN.
27-5/16" MAX.
Recommended
cutout location
from the floor
32-1/2"
30''
F
E
Conduit
48"
Cutout depth
23-1/2" MIN
22" to
bottom of
junction box
Junction box
location
9-1/2" MAX.
D
23" min. door opening
allowance for drop-down doors,
and 30" min. allowance for
side-swing doors.
JTS3000DNBB, JTS3000DNWW, JTS3000ENES,
JTS3000SNSS, JTS5000BNTS, JTS5000DNBB,
JTS5000DNWW, JTS5000ENES, JTS5000FNDS,
JTS5000SNSS, PTS7000BNTS, PTS7000FNDS,
PTS7000SNSS, PTS700LSNSS, PTS700RSNSS
GE® 30" Smart Built-In Self-Clean Convection
Single Wall Oven with Never Scrub Racks
DIMENSIONS AND INSTALLATION INFORMATION
NOTE: Single wall ovens are NOT approved for
stacking above or below another single wall oven.
NOTE: Wall coverings, countertops and cabinets
surrounding the wall oven must be able to
withstand a temperature of up to 200°F (94°C).
NOTE: If the cabinet in which the wall oven is
installed does not have a solid bottom, two braces
or runners must be installed to support the weight
of the oven. The runners and braces must support
up to 220 lbs (99 kg).
NOTE: Door handle protrudes 3" from door face.
Cabinets and drawers on adjacent 45° and 90°
walls should be placed to avoid interference with
the handle.
ATTENT ION INSTAL LE R : Electric wall ovens
are NOT approved for installation with a plug
and receptacle. They must be hard wired into an
approved junction box.
IMPORTANT: Before installing, consult
installation instructions packed with product for
current dimensional data.
KW R AT ING
24 0V 4.2
208V 3.2
BREAKER SIZE
24 0V 20 Amps
208V 20 Amps
For answers to your GE Profile™ or GE Appliances
product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
Suitable
bracing
to support
runners
23" min. door opening
allowance for drop-down doors,
and 30" min. allowance for
(must support 220 lbs.)
E
C
Cutout width
28-1/2" MIN.
9-1/2" MAX.
Cutout depth
23-1/2" MIN
F
Conduit
48"
D
Dimension and installation information are shown in inches.
2 x 4 or
L
equivalent runners
level with bottom of cutout
and flush with sides of cutout
or solid bottom floor.
Junction box
location
22" to
bottom of
junction box
B
Cabinet 30"
A - Overlap of oven at top of cutout 1"
B - Overlap of oven other side of edge of cutout 3/4"
28-5/8" MAX.
A
C
30''
Cutout height
27-1/4" MIN.
27-5/16" MAX.
Recommended
cutout location
from the floor
32-1/2"
JTS5000
C - Overlap of oven at bottom of cutout 1-1/4"
Oven
D - Install depth 23-1/2"
E - Overall height with trim 28-5/8"
F - Overall width 29-3/4"
Listed by
ADA
COMPLIANT
Underwriters
Laboratories
Specification Revised 10/20

JTS5000DN/BN/EN/FN/SN
Gas or Electric Cooktops May Be Installed Over This Oven.
See Cooktop Installation Instructions for Cutout Size.
See Label on Top of Oven for Approved Models.
240V/208V
Junction Box
Location
(junction box may
be in adjacent
cabinet)
Gas or Electric Connections for Gas
Cooktop Must be Located in an Adjacent
Accessible Location to the Right
Top and/or Side Fillers
May Be Necessary if
Unit is Positioned
Between Existing
Cabinets. Be Sure
They Are Attached
Securely, Since They
Will Anchor the Oven
in the Cabinet.
22" (55.9 cm) min.
Above Support
Platform
36" (91.4 cm)
Countertop
Height
Must Match
Toekick Height
24" (61 cm)
4" (10.2 cm)
Toekick
25" (63.5 cm)
MUST SUPPORT 220 lbs. (99 kg) FOR SINGLE OVENS
3/4" (1.9 cm)
Support Platform
Required
Side-bySide Installations
Install two ovens in separate cutouts.
Location
cabinet)
Gas or Electric Connections for Gas
Cooktop Must be Located in an Adjacent
Accessible Location to the Right
22" (55.9 cm) min.
Above Support
Platform
36" (91.4 cm)
Countertop
Height
Must Match
Toekick Height
24" (61 cm)
4" (10.2 cm)
Toekick
Gas or Electric Cooktops May Be Installed Over This Oven.
See Cooktop Installation Instructions for Cutout Size.
See Label on Top of Oven for Approved Models.
240V/208V
Junction Box
Location
(junction box may
be in adjacent
cabinet)
Gas or Electric Connections for Gas
Cooktop Must be Located in an Adjacent
Accessible Location to the Right
Top and/or Side Fillers
May Be Necessary if
Unit is Positioned
Between Existing
Cabinets. Be Sure
They Are Attached
Securely, Since They
Will Anchor the Oven
in the Cabinet.
2 1/2" min. (6.4 cm)
31 1/4" min.
(79.4 cm)
Cooktop
Wall Oven
SIDE OVEN
IMPORTANT:
Maintain a minimum
distance of 31 1/4"
from the top surface
of the countertop to
the wall oven
platform to ensure
that the cooktop and
wall oven do not
interfere with each
other (see picture).
22" (55.9 cm) min.
Above Support
Platform
36" (91.4 cm)
Countertop
Height
Must Match
Toekick Height
24" (61 cm)
4" (10.2 cm)
Toekick
25" (63.5 cm)
MUST SUPPORT 220 lbs. (99 kg) FOR SINGLE OVENS
3/4" (1.9 cm)
Support Platform
Required
Side-bySide Installations
Install two ovens in separate cutouts.
GE® 30" Smart Built-In Self-Clean Convection
Single Wall Oven with Never Scrub Racks
DIMENSIONS AND INSTALLATION INFORMATION
NOTE: 30" Single electric wall ovens are approved for
installation below a countertop, and below certain gas and
electric cooktops. Refer to the Approved Combinations Matrix
available at geappliances.com for specific information.
NOTE: 30" Single electric wall ovens are approved for
installation above 27" and 30" warming drawers.
ATTENTION INSTALLER: Electric wall ovens are NOT
approved for installation with a plug and receptacle. They must
be hard wired into an approved junction box.
IMPORTANT: Before installing, consult installation
instructions packed with ALL products for current dimensional
and combination data.
SIDE-BY-SIDE INSTALLATION
(TWO OVENS IN SEPARATE CUTOUTS)
Cutout – observe
all dimensions and
requirements
NOTE: One cooktop may be centered over either
oven in the side-by-side installation.
For answers to your GE Profile™ or GE Appliances
product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
Center Line Center Line
30.5" (77.5 cm) 30" models
27" (68.58 cm) 27" models
Cooktop
Cutout – observe
all dimensions and
requirements
2" (5.1 cm) min.
UNDERCOUNTER INSTALLATION
INSTALLATION BELOW A COOKTOP
2 1/2" min. (6.4 cm)
IMPORTANT:
Maintain a minimum
distance of 31 1/4"
from the top surface
of the countertop to
the wall oven
platform to ensure
that the cooktop and
wall oven do not
interfere with each
other (see picture).
31 1/4" min.
(79.4 cm)
Cooktop
Wall Oven
SIDE OVEN
Specification Revised 10/20