GE IC754CBF12CTD, IC754CGF12CTD, IC754CSF12CTD, IC754VBF12CTD, IC754VGF12CTD Operator Interface Products

...
Page 1
GE
Intelligent Platforms
Operator Interface Products
12" QuickPanel* View & QuickPanel Control
Loaded Color TFT
IC754CBF12CTD IC754CGF12CTD IC754CSF12CTD IC754VBF12CTD IC754VGF12CTD IC754VSF12CTD IC754OBF12CTD
Hardware User's Guide, GFK-2284D
December 2010
Page 2
Warnings, Cautions, and Notes
as Used in this Publication
Warning
Warning notices are used in this publication to emphasize that hazardous voltages, currents, temperatures, or other conditions that could cause personal injury exist in this equipment or may be associated with its use.
In situations where inattention could cause either personal injury or damage to equipment, a Warning notice is used.
Caution
Caution notices are used where equipment might be damaged if care is not taken.
Note: Notes merely call attention to information that is especially significant to
understanding and operating the equipment.
This document is based on information available at the time of its publication. While efforts have been made to be accurate, the information contained herein does not purport to cover all details or variations in hardware or software, nor to provide for every possible contingency in connection with installation, operation, or maintenance. Features may be described herein which are not present in all hardware and software systems. GE Intelligent Platforms assumes no obligation of notice to holders of this document with respect to changes subsequently made.
GE Intelligent Platforms makes no representation or warranty, expressed, implied, or statutory with respect to, and assumes no responsibility for the accuracy, completeness, sufficiency, or usefulness of the information contained herein. No warranties of merchantability or fitness for purpose shall apply.
* indicates a trademark of GE Intelligent Platforms, Inc. and/or its affiliates. All other
trademarks are the property of their respective owners.
©Copyright 2004 – 2010 GE Intelligent Platforms, Inc.
All Rights Reserved
Page 3
Contact Information
Online technical support and GlobalCare
www.ge-ip.com/support
Additional information
http://www.ge-ip.com/
Solution Provider
solutionprovider.ip@ge.com
Online Technical Support
www.ge-ip.com/support
Phone
1-800-433-2682
International Americas Direct Dial
1-780-420-2010 (if toll free 800 option is unavailable)
Technical Support Email
support.ip@ge.com
Customer Care Email
customercare.ip@ge.com
Primary language of support
English
Online Technical Support
www.ge-ip.com/support
Phone
+800-1-433-2682
EMEA Direct Dial
+352-26-722-780 (if toll free 800 option is unavailable or if dialing from a mobile telephone)
Technical Support Email
support.emea.ip@ge.com
Customer Care Email
customercare.emea.ip@ge.com
Primary languages of support
English, French, German, Italian, Czech, Spanish
Online Technical Support
www.ge-ip.com/support
Phone
+86-400-820-8208 +86-21-3217-4826 (India, Indonesia, and Pakistan)
Technical Support Email
support.cn.ip@ge.com (China) support.jp.ip@ge.com (Japan) support.in.ip@ge.com (remaining Asia customers)
Customer Care Email
customercare.apo.ip@ge.com customercare.cn.ip@ge.com (China)
If you purchased this product through an Authorized Channel Partner, please contact the seller directly.
General Contact Information
Technical Support
If you have technical problems that cannot be resolved with the information in this guide, please contact us by telephone or email, or on the web at www.ge-ip.com/support
Americas
Europe, the Middle East, and Africa
Asia Pacific
Page 4
Page 5
Notices
GE Intelligent Platforms reserves the right to make improvements to the products described in this publication at any time and without notice.
QuickPanel, QuickPanel View, and QuickPanel Control are trademarks of GE Intelligent Platforms in the United States and other countries. Any other trademarks referenced herein are the property of their respective owners and used solely for purposes of identifying compatibility with the products of GE Intelligent Platforms.
The 12” QuickPanel View/Control has been tested and found to meet or exceed the requirements of U.S. (47
CFR 15), Canadian (ICES-003), Australian (AS/NZS 3548) and European (EN55022) regulations for Class A digital devices when installed in accordance with guidelines noted in this manual.
Microsoft® requires the following notes be published according to their additional licensing provisions:
Users are advised that a maximum of ten (10) computers or other electronic devices may simultaneously connect to, access and use services of the Microsoft Windows® CE Operating system on the QuickPanel View/Control solely for remote access (including connection sharing) The ten connection maximum includes any indirect connections made through ‘multiplexing’, or other software or hardware which pools or aggregates connections.
Note that the QuickPanel View/Control does not provide any server functionality utilizing Remote Desktop Protocol (RDP) to remotely connected client computers or devices. However, it does support connectivity to a remote Microsoft® Terminal Services server. The server providing these services must meet these restrictions and other Microsoft licensing requirements as applicable.
Notice Regarding Video Standards
This product is licensed under one or more video patent portfolio licenses such as and without limitation VC-1 and MPEG4 Part 2 Visual for the personal and non-commercial use of a consumer to:
(i) Encode video in compliance with the standards licensed under such patent portfolio licenses and/or
(ii) Decode video that was encoded by a consumer engaged in a personal and non-commercial activity and/or was obtained from a video provider licensed to provide video under such patent portfolio licenses.
Such license extends to this product only and only to the extent of other notices which may be included in this document. The license does not extend to any other product regardless of whether such product is included with this licensed product in a single article. No license is granted or shall be implied for any other use. Additional information may be obtained from MPEG LA, L.L.C. See http://www.mpegla.com.
The FCC requires the following note to be published according to FCC guidelines:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Any changes or modifications to the product or installation that are not expressly approved by GE Intelligent Platforms could void the user's authority to operate the equipment under FCC rules.
Industry Canada requires the following note to be published:
This Class A digital apparatus complies with Canadian ICES-003.
Page 6
Notices
The following statements are required to appear for Class I Division/Zone 2 Hazardous Locations.
1. WARNING – EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR
SUITABILITY FOR CLASS 1, DIVISION 2.
2. WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER
BEFORE REPLACING OR WIRING MODULES.
3. WARNING - EXPLOSION HAZARD - DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS
POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS.
Power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods, Article 501 10(b) of the National Electric Code, NFPA 70 and in accordance with the authority having jurisdiction.
Users must supply an isolated DC supply to power the QuickPanel models covered by this manual. The power supply to the QuickPanel must be limited by a slow blow fuse not to exceed a maximum 100VA. For less than 20Vdc input, the fuse must be rated for no more than 5A.
For a complete list of agency approvals, please refer to Appendix A
Page 7
Contents
Welcome .................................................................................................. 1-1
Getting Started ............................................................................................. 1-2
Firmware Updates ........................................................................................ 1-5
Overview .................................................................................................. 2-1
QuickPanel View/Control Hardware............................................................. 2-2
QuickPanel View/Control Software .............................................................. 2-5
Installation Procedures for Conformance and Compliance ...................... 3-1
Connecting a DC Power Supply .................................................................. 3-2
Panel Cutout ................................................................................................ 3-3
Mounting Bracket Locations ......................................................................... 3-4
Mounting the QuickPanel View/Control in a Panel ...................................... 3-5
Detailed Operation ................................................................................. 4-1
Touch Screen Display .................................................................................. 4-2
Communication Ports ................................................................................. 4-13
CF Port ....................................................................................................... 4-25
Universal Serial Bus (USB) ........................................................................ 4-27
Ethernet ...................................................................................................... 4-28
Printing ....................................................................................................... 4-33
Expansion Bus ........................................................................................... 4-36
DIP Switches .............................................................................................. 4-37
Memory ...................................................................................................... 4-39
Other Subsystems ..................................................................................... 4-44
Specifications .......................................................................................... A-1
Physical ........................................................................................................ A-1
DC Power ..................................................................................................... A-1
Display ......................................................................................................... A-2
Front Panel ................................................................................................... A-2
Touch Screen ............................................................................................... A-2
CPU .............................................................................................................. A-3
Memory ........................................................................................................ A-3
Memory Expansion Slot ............................................................................... A-3
Expansion Ports ........................................................................................... A-4
Communication Ports ................................................................................... A-4
Environmental .............................................................................................. A-5
Battery .......................................................................................................... A-5
GFK-2284D iii
Calendar/Clock............................................................................................. A-5
Page 8
Contents
Diagnostics ........................................................................................... B-1
Agency Approvals ........................................................................................ A-6
Power up ...................................................................................................... B-1
Pocket Internet Explorer .............................................................................. B-1
Physical Unit ................................................................................................ B-2
iv 12" QuickPanel* View & QuickPanel Control Loaded Color TFT –December 2010 GFK-2284D
Page 9
Chapter
1
Welcome
Congratulations on your purchase of a QuickPanel View/Control. The QuickPanel View/Control is available in different configurations to suit your requirements, either as a full-featured HMI, or as a combination of HMI and controller for local and distributed control applications. Equally adept in a networked environment or as a standalone unit, the QuickPanel View/Control is the ideal solution for factory floor HMI and control.
Powered by Microsoft Windows® CE, today’s embedded control operating
system of choice, the QuickPanel View/Control provides a fast track for application program development. The commonality with other versions of Windows simplifies porting your existing program code. Another benefit of Windows CE is the familiarity of the user interface, shortening the learning curve for operators and developers alike. The availability of third-party application software makes this operating system even more attractive.
The 12" QuickPanel View & QuickPanel Control is an all-in-one microcomputer designed for maximum flexibility. The design, based on an advanced XScale microprocessor, brings together a high-resolution touch-screen operator interface with a variety of I/O options. With many standard ports and expansion busses from which to choose, you can connect to most industrial equipment.
The QuickPanel View/Control is equipped with several memory types to satisfy even the most demanding applications. A 64MB section of DRAM is split between the operating system, an object store and application memory. Functioning as a virtual hard drive, a 64MB section of non-volatile FLASH memory is divided between the operating system and persistent storage for application programs. The retentive memory consists of 512KB of battery-backed SRAM for data storage, ensuring your valuable data will never be lost, even during a power failure.
The many features of the QuickPanel View/Control make it an obvious choice for a world of applications. Your smart choice will provide reliable operation for years to come.
GFK-2284D 1-1
Page 10
1
Getting Started
Basic Setup
Your QuickPanel View/Control is shipped ready for use after a few configuration steps. To power up all you need to do is connect a DC power supply via the supplied quick-connect plug. Depending on your application, you may also want to connect and configure optional input devices, communications ports and expansion adapters (see chapter 3).
Caution
Electrical Shock Hazard: To avoid personal injury or damage to equipment, ensure that the DC supply is disconnected from power and that the leads are not energized before attaching them to the unit's power supply plug.
1-2 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 11
1
Runtime Setup
To download an application to a QuickPanel View or QuickPanel Control unit, you must set up a data link between it and your development workstation. For
more information, see “Ethernet” in chapter 3 and “Downloading a Machine Edition Project” in the Machine Edition online help.
Model IC754OBF12CTD does not require Proficy Machine edition to set the unit up for operation. For this model, applications must be loaded via ActiveSync, a network connection, a compact flash (CF) card or USB stick.
Startup
When you first start up the QuickPanel View or QuickPanel Control, a few configuration steps are necessary.
To start the QuickPanel View/Control
1. Apply DC power to the QuickPanel View/Control. Once power is applied, the QuickPanel View/Control begins initializing.
The first thing to appear on the display is the splash screen.
2. To skip running any programs included in the StartUp folder, tap Don’t
run StartUp programs.
The splash screen disappears automatically after about 5 seconds. The Windows CE desktop then becomes visible.
3. Tap
Start, point to Settings and then tap Control Panel.
4. In the Control Panel, double-tap Display to configure the LCD
display.
GFK-2284D Chapter 1 Welcome 1-3
Page 12
1
5. In the Control Panel, double-tap Stylus to configure the touch screen.
6. In the Control Panel, double-tap Date and Time to configure the system clock.
7. In the Control Panel, double-tap System to configure a network machine name. Many applications, including Proficy Historian require a unique machine name. It is recommended procedure to set a unique network name for the QuickPanel View/Control to avoid future conflicts.
8. In the Control Panel, double-tap Network and Dial-up Connections to configure network settings.
9. To save the settings, run Backup.
Shutdown
There are no specific dangers associated with a power failure or other unplanned shutdown of the QuickPanel View/Control. In general, programs are retained in FLASH memory and user data can be retained in battery-backed SRAM. Some operating system settings are retained only with user intervention. We recommend the following procedure to shut down the QuickPanel.
To shut down the QuickPanel View/Control
1. Quit any programs that are running and wait for all file operations to complete.
2. If you have not changed operating system settings (e.g., brightness or touch screen sensitivity) or do not want to save the changes, remove AC power from the DC supply.
3. To save changes to operating system settings (e.g., brightness, touch screen sensitivity) run Backup. When the Backup dialog box displays
Completed Successfully, remove power from the DC power supply connected to the QuickPanel.
1-4 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 13
1
Firmware Updates
Updates to the QuickPanel firmware are available on the Support web site. This allows you to update the unit to the most recent released version of the firmware with the latest feature updates and issues addressed.
GFK-2284D Chapter 1 Welcome 1-5
Page 14
Page 15
Chapter
2
Overview
This chapter provides introductory information on the 12" QuickPanel View/Control hardware and software with procedures for completing some of the most common tasks you will encounter.
In this chapter:
QuickPanel View/Control Hardware 2-2
Provides a layout diagram showing user-accessible controls and indicators, and a block diagram showing module functions.
QuickPanel View/Control Software 2-5
Working with Windows CE, working with Pocket Internet Explorer, backing up registry or desktop changes, rebooting the system, using Storage Manager and System Information utilities, using Microsoft file viewers, copying projects to the Flash Card, updating a Machine Edition project from the CF card, emulating a Pocket PC, using the HTTP File Transfer Utility, and using FTP Server.
GFK-2284D 2-1
Page 16
2
QuickPanel View/Control Hardware
Layout Diagram
In addition to the primary touch screen interface, the 12" QuickPanel View/Control supports a variety of communication ports including an expansion bus to allow great flexibility in application. The back of the QuickPanel opens allowing access to the expansion bus connector, memory expansion connector, DIP switches and battery. The following diagram shows the physical layout of the QuickPanel View/Control and the locations of ports and connections.
Caution
Remove power from the QuickPanel View/Control before
opening the back. Working on a “live” unit may result in
damage to equipment and injury to personnel. Always use anti-static precautions (i.e. grounded wrist strap) when accessing the interior of the unit. Do not allow conductive material, liquid or solid, to contact the electronics of the QuickPanel.
The bottom LED is green when power is applied and amber if both backlights fail; the top LED is tricolor (green, red, or amber) and programmable.
Note: Backlights are not field-replaceable.
2-2 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 17
2
and battery
Physical Layout of QuickPanel View/Control
GFK-2284D Chapter 2 Overview 2-3
Page 18
2
64 MB DRAM
DRAM Expansion
100 pin DIMM
64 MB max.
64 MB Flash
512 KB EPROM
Boot
512 KB BBSRAM
Buffer
Field Bus
Expansion
Proprietary Expansion
XScale
PXA255
Touch
Screen
Backlit
LCD Display
Touch
Screen
Controller
RS232
RS232 RS485
CF Card
Controller
USB
Controller
4-pos.
DIP Switch
Real-time
Clock
Status
LEDs (2)
COM2
9 pin
Batt.
COM1 25 pin
Ethernet
Controller
Ethernet
Port RJ45
CF Card
Slot
USB
Port 1
USB
Port 2
100Mhz Bus
Data/Address Bus
I2C Bus
SVGA
Controller
Backlight
Monitor
Custom Logic
Batt.
Monitor
Batt.
Display
Brightness
Custom
Logic
Ethernet
Controller
Ethernet
Port RJ45
Misc.
Block Diagram
The 12" QuickPanel View/Control is based on the XScale microprocessor, and employs large-scale integration to provide high performance with a small footprint. The following block diagram illustrates the major functional areas of the QuickPanel View/Control and the interfaces between them.
2-4 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 19
2
QuickPanel View/Control Software
Windows CE
Microsoft Windows CE is the operating system for the QuickPanel View/Control. It is a full 32-bit O/S with a graphical user interface. This operating system is finding widespread application in hand-held PCs and embedded controllers, such as the QuickPanel View/Control. The familiar look and feel of Windows CE shortens the learning curve for users having
experience with Windows 95/98/NT/2000/ME/XP. From a software developer‟s
perspective, the CE environment is a subset of the WIN32 application programming interface, simplifying the porting of existing software from other versions of Windows.
The QuickPanel View/Control operating system is stored in a 16 MB block of FLASH memory and copied to a block of DRAM for execution. The operating system starts automatically following a power-up or reset of the QuickPanel View/Control.
For more on Windows CE visit
http://www.microsoft.com/windowsembedded/en-us/default.mspx.
GFK-2284D Chapter 2 Overview 2-5
Page 20
2
Keyboard Shortcut
Action
CTRL+ESC or
Opens the Windows CE Start menu. Use arrow keys to select a program and ENTER to run it.
ALT+TAB
Starts the Task Manager. Use it to quit unresponsive programs.
CTRL+ALT+=
Starts the touch screen calibration.
SPACEBAR
Equivalent to single-tap.
ENTER
Equivalent to double-tap. In a dialog box, equivalent to OK.
TAB
In a dialog box, select next control.
SHIFT+TAB
In a dialog box, select previous control.
ESC
Close dialog box, discarding changes.
ARROW KEYS
In a dialog box, select controls or items from a list box.
Working with Windows CE
Although the main user input device when working with Windows CE is the touch screen, it can often be convenient to use keyboard shortcuts, such as those described in the following table.
To place a program in the
Start menu
1. Start Windows Explorer.
2. Navigate to the program you want to place in the Start menu.
3. Tap the program‟s icon to select it.
4. From the Edit menu, choose Copy.
5. Navigate to the ‟\Windows\Programs\„ folder.
6. From the Edit menu, choose Paste Shortcut.
7. To save the settings, run Backup (see page 2-10).
2-6 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 21
2
Pocket Internet Explorer
Microsoft‟s Pocket Internet Explorer is a fully integrated browser within the Windows CE operating system. This browser allows you to connect with an Internet service provider and view web sites.
Pocket Internet Explorer supports JScript. Java support can be added from third-party sources. Pocket Internet Explorer does not support VBScript; however, VBScript components are included in the operating system and may be used by third-party applications such as Proficy Machine Edition.
A connection can be established over a dial-up connection (default) or an Ethernet network. The Ethernet or dial-up connection must first be properly configured.
To configure a dial-up connection
1. Start Pocket Internet Explorer
2. From the Tools menu, choose Options. The Internet Options dialog box appears.
3. On the Connection tab, select the dial up connection from the Autodial name box. (This example uses a connection named “MyISP.”)
4. Tap OK.
5. To save the settings, run Backup (see page 2-10).
GFK-2284D Chapter 2 Overview 2-7
Page 22
2
To configure a LAN Connection
1. Start Pocket Internet Explorer
2. From the Tools menu, choose Options. The Internet Options dialog box appears.
3. On the Connection tab, select the Use LAN check box.
4. Tap OK.
5. To save the settings, run Backup (see page 2-10).
2-8 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 23
2
To configure a Proxy server
1. Start Pocket Internet Explorer.
2. From the Tools menu, choose Options.
The Internet Options dialog box appears.
3. On the Connection tab, select the Access the Internet using a proxy server check box.
4. In the Address box, type the URL of your proxy server (see your ISP or network administrator).
5. In the Port box, type the server‟s port number for HTTP access.
6. Select the Bypass Proxy for Local Addresses check box to connect directly to sites like your intranet.
7. Tap OK.
8. To save the settings, run Backup (see page 2-10).
GFK-2284D Chapter 2 Overview 2-9
Page 24
2
Backup
Backup saves changes that you make to the Windows Registry or Desktop to Flash memory. This utility is required because the QuickPanel View/Control is not battery powered. Specifically, Backup does the following:
It stores the Windows CE registry (including any control panel settings)
in Flash memory.
It stores any changes (or additions) made to the „\Windows‟ subtree of
the file system in the user block of FLASH memory.
Run Backup whenever you make configuration changes to the operating system or installed applications, and prior to shutting down the QuickPanel View/Control.
To run the Backup program
1. On the desktop, double-tap Backup. The Backup dialog box appears.
2. Tap OK.
2-10 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 25
2
Reboot
Reboot performs a controlled and orderly shut down of the Windows CE operating system, then restarts the QuickPanel View/Control. This ensures all open files are closed properly.
To reboot the system
1. To save changes to system configurations, run Backup (see page 2-10).
2. Tap Start, point to Programs, then the System folder, and tap
Reboot.
A confirmation dialog box appears.
3. Tap “Yes.” The operating system reboots.
GFK-2284D Chapter 2 Overview 2-11
Page 26
2
Storage Manager
Use Storage Manager to repair or format lost or corrupted data volumes. Storage Manager can repair data volumes existing either in Compact Flash (CF), battery-backed SRAM (BBSRAM), or USB Flash Keys (thumb drives). Data volumes existing in the main flash file system of the QuickPanel may not be repaired by Storage Manager.
Storage Manager, accessed from the Control Panel folder, is a Microsoft product for which on-line help is available.
2-12 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 27
2
System Information
System Information is a custom utility that displays a splash screen with the following information:
Operating System version. For example, „Windows CE 5.00‟. Platform. Identifies the host hardware, its version and build number.
Tapping More Info on the splash screen opens the Advanced System Information window, which provides information such as hardware version and serial number, CPU type and specifications, etc. This information can be especially useful if you are contacting Technical Support.
To run the System Information program
1. On the desktop, double-tap System Information.
The System Information splash screen appears.
2. Tap More Info to open the Advanced System Information window, or tap Close to continue.
Network information alone can be viewed by double-tapping the icon displayed on the taskbar for each connection.
GFK-2284D Chapter 2 Overview 2-13
LAN
Page 28
2
Microsoft File Viewers
Included with Windows CE are applications that enable you to view files in three popular formats: Microsoft® Word, Excel, and Adobe® PDF. Each application provides online help for its use.
To access the Microsoft file viewers
Tap
Start, point to Programs, point to Microsoft File Viewers, and
then choose one of the following:
Microsoft Excel Viewer
Microsoft PDF Viewer Microsoft Word Viewer
File Viewer Limitations
Microsoft Excel:
Hyperlinks are not supported.  Data Tables in charts are not supported.  WordArt is not supported. Plain text will be substituted.  Surface charts. An image representing an unsupported chart will
appear in the chart's location.
Certain types of 3D charts will be mapped to equivalent 2D charts.  Supported 3D charts are only shown at a fixed camera angle.  Vertical text in the worksheet is mapped to 90 degree rotated text.
2-14 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 29
2
Microsoft PDF:
Advanced features, such as PDF forms, encrypted files, CCITTFaxDecode images, clip paths, predictive GZIP decoding, CMYK JPEGs, annotations, and transitions are not supported.
In addition the Microsoft PDF Viewer operates with the following limitations:
Poly-polygons are treated as polygons and therefore may have the
interiors filled.
Embedded TrueType fonts are not used. They are mapped to existing
fonts already installed on the system.
Colors from unsupported color spaces, such as ICCBased or DeviceN
color, may be displayed incorrectly.
Text rotation is only shown in 90 degree increments.  Type 1 fonts are mapped using either the encoding or Unicode
mappings, if possible.
Type 3 fonts are not supported, but an attempt is made to map them if
a Unicode map exists.
Microsoft Word:
WordArt is not supported.  Hyperlinks are not supported.  Some types, styles, and groupings of AutoShapes will not appear.  Word forms for Text boxes are not supported. Elements from the form
may be visible but will not be available for input.
GFK-2284D Chapter 2 Overview 2-15
Page 30
2
Copy Project to External Flash
RestorePCCard is a custom utility for transferring Proficy Machine Edition projects between compatible QuickPanel View/Control units via CF cards, USB flash keys, or PCMCIA flash, if the unit is fitted with the optional PCMCIA interface expansion card. (Flash memory not included with PCMCIA expansion card.)
Caution: Ensure that the copy or update operation is complete (i.e., no busy or wait cursor displays) before disconnecting power.
To copy a Machine Edition project to CF card or USB stick
1. Ensure there is a blank CF card or USB stick in the in the appropriate port.
2. Double tap the Copy Project to Flash Card icon on the desktop.
If there is more than one of the supported flash devices installed, a Select Media confirmation dialog will appear allowing you to choose the destination location for the backup. From the drop list, choose the destination and then select OK to continue. This dialog does not appear when there is only one flash device present.
3. Tap Yes when the Copy Project Query confirmation dialog box appears.
The system copies the project onto the CF card or USB stick.
Caution
Creating a project copy while the Machine Edition runtimes are active may cause an incomplete copy to be created if the runtimes are also writing to files in the project folders. The utility can detect this situation and will warn you to stop the runtimes before making the backup. You will not be able to create a backup while the runtimes are writing files.
2-16 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 31
2
To update a Machine Edition project
You can update a Machine Edition application currently stored on the QuickPanel View/Control with a revision stored on a flash device, such as a CF card or USB memory stick.
1. Insert the flash device containing an upgraded version of the Machine Edition project into the appropriate port.
2. Reboot the machine (see page 2-11). See the settings section below, as depending on options set, the update
may or may not be enabled, or may automatically update. If there is more than one flash device with a valid project copy present, a Select Media confirmation dialog will appear allowing you to choose which flash device to update with. Select the device from the list and select OK to continue. When a valid project is found on the flash device, you will be prompted to install the project or skip it. Tap OK to install or Cancel to skip the install and continue to boot. If an invalid project is found, an error message appears in a dialog box. This dialog box must be closed before boot will continue.
3. Remove the flash device from the port.
GFK-2284D Chapter 2 Overview 2-17
Page 32
2
To change utility settings
This utility can be configured to change the way the Machine Edition project update will occur.
1. Tap Start, point to Settings and then tap Control Panel.
2. In the Control Panel, double-tap Project Transfer to configure the RestorePCCard utility settings.
3. Select from the list which option you wish to use:
Wait for Answer
This is the default setting. If an update image is present, the user will be prompted to install this update as described above. If the update dialogs are not closed, the unit will not complete the boot cycle.
Always Restore
With this setting there will be no prompts to confirm installing the update (if one is present). The update will occur as though the user selected the option to install the update.
Note: If more than one update is found due to multiple flash devices
having valid update images, the user will still have to select which image to use. For fully automatic updates, ensure there is only one update image present.
Skip at Startup
With this setting, all update images are ignored during the boot.
2-18 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 33
2
Timeout after:
With this setting selected, a second setting control appears, allowing for entry of a timeout interval (in seconds) for the update utility to wait for a user response to its dialogs, before automatically continuing to boot without an update occurring. The user has the amount of time specified to either cancel the update or continue with the update as normal. Setting the time to 0 seconds will make this option operate the same as the Skip at Startup setting.
4. Select OK to keep your setting choice. To save the settings, run Backup (see page 2-10).
Emulate PPC
Emulate PPC is a utility that allows the QuickPanel to emulate a Pocket PC 2003 during an ActiveSync session, enabling the download of third-party Pocket PC 2003 software.
To use Emulate PPC during an ActiveSync session
1. Start Windows Explorer, double tap EmulPPC.
The Emulate PPC dialog box appears.
2. Start the ActiveSync session. When installation of third party software is
complete, close the dialog box to deactivate Emulate PPC.
Windows, then double tap
GFK-2284D Chapter 2 Overview 2-19
Page 34
2
HTTP File Transfer Utility
The HTTP File Transfer Utility (HFTU) is a small, standalone command line program that allows you to send and delete files to and from computers over a network. The HFTU uses the HTTP protocol, so you can even send files to computers over the Internet.
Run the HTTP utility from a command line prompt, from a batch file (.BAT) or as an application call in a script. The HTTP utility is an executable (.EXE) file included in the 12" QuickPanel View & QuickPanel Control‟s operating system.
The HTTP utility currently supports two file transfer commands: COPY and DELETE.
Note: In order to function, the HTTP File Transfer utility requires both
computers to have web servers that support PUT functionality. (Most web servers support PUT, including the Proficy Machine Edition web server installed with the runtimes for View and Logic Developer - PC.) If in doubt, check the documentation for your web server.
To use the HTTP utility
1. From the Start menu, choose Programs, then choose Command Prompt.
The Command Line editor appears.
2. Type commands as required.
2-20 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 35
2
3. Use the following syntax:
HTTPUTIL COPY source destination
Where “source” is the URL of the source file, and “destination” is the URL of
the destination file. For example:
HTTPUTIL COPY \MyFile.txt http://MyServer/webfiles/MyFileBACKUP.txt
Copies a file called MyFile.txt on drive C: of the local computer to the webfiles folder under the web server at //MyServer. Note that you can rename a file as you copy it.
HTTPUTIL DELETE url
Where “url” is the remote URL of the file you want to delete. This URL must use the “//” or ”HTTP://” syntax. For example:
HTTPUTIL DELETE http://MyServer/webfiles/MyFileBACKUP.txt
Deletes a file called MyFileBACKUP.txt from the webfiles directory under the web server at HTTP://MyServer.
GFK-2284D Chapter 2 Overview 2-21
Page 36
2
FTP Server
The FTP Server included with the QuickPanel View/Control supports both standard (RFC 959) and Explicit FTPS (i.e., FTP/SSL, Auth TLS, TLS-C, RFC-
4217). It does not support SFTP or implicit FTPS, which uses different ports and is based on SSH rather than SSL.
All configuration of the FTP server is accomplished with the Secure FTP Server control panel applet. By default, the server is not enabled. Once enabled, a background program will run, waiting for clients to connect. Up to ten connections are supported. Sessions that are idle for five minutes are terminated by the server.
2-22 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 37
2
The Server supports:
Non-secure operation. All information including username, password,
and data is transmitted with no encryption and susceptible to packet sniffing and various FTP attacks. This is the default.
Both secure and non-secure operation. This mode of operation, either
secure or non-secure, is determined by the client when it connects.
This operation is active when „Support Secure Connection‟ is enabled,
but „Required‟ is not.
Secure operation only. Secure operation uses encrypted connections
for the control connection. The data connections are encrypted or non­encrypted based on the settings of the client. Secure operations also require the server to have a signed server certificate it can use to prove it is the actual machine the client wanted to reach and not an imposter.
This mode is active when both „Support Secure Connection‟ and
„Required‟ are enabled.
By default, the server requires a username/password combination to be configured. The server supports one username/password combination to authenticate remote users. There are three modes of authentication operation:
No support for anonymous login. This is the default.  Anonymous with no password. This is enabled when „Allow
Anonymous Access‟ is checked, but „Require Username and
Password„ is not checked.
Anonymous with password requested (but not validated). This is
enabled when „Allow Anonymous Access‟ and „Require Username and
Password‟ are checked. This can prevent some types of attacks and is
required by some clients.
Note: To save the settings, run Backup (see page 2-10). Once connected, a remote user is logged into the FTP root directory. This is
available from the QuickPanel View/Control as \Temp\ftp and is a volatile RAM area. Files placed in this area are not persisted over a power cycle/reboot and use memory from the Storage Memory allocation. For this reason, remote users are only able to read, rename and delete files from the FTP root directory. Programs running on the QuickPanel can access the \Temp\ftp like any other folder, but remote users cannot fill up storage memory.
GFK-2284D Chapter 2 Overview 2-23
Page 38
2
All removable flash devices appear to remote FTP users as directories off the FTP root directory. PC Flash card partitions appear as directories such as \PCFlashStorage and USB Flash Keys as directories such as \USBStorage. The names contain no spaces, as FTP commands do not support spaces in filenames. Full access privileges are granted for the client in these folders/devices.
Removable flash device directories are captured when a session is opened and are not changed while the session exists. If you start without a CF card installed, you will have to close your session and login again to see the CF directory. If the CF card existed when you logged in and is removed and
inserted, it will still work provided the CF card‟s device name did not change
during reinsertion. A server certificate is a special type of document that contains information
about the server‟s settings and a chain of electronic signatures to guarantee the
document has not been altered. A Server certificate must be chosen in the Secure FTP Server control panel applet from the certificates installed on the QuickPanel View/Control.
The certificate itself is imported with the Certificates control panel applet. The main requirements of the certificate are that it must have the server authentication key usage attribute set and the name of the certificate should match the name used to connect to the FTP server (which could be the IP address of the server).
Certificates can either be purchased from an online vendor and imported into the QuickPanel View/Control, or a self-signed certificate can be generated from the QuickPanel View/Control. The benefit of a purchased certificate is that any
2-24 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 39
2
user that has the root certificate used by the online vendor can determine the certificate is valid without the need for any additional information. A self-signed certificate is only known to be valid by clients that have added the certificate to their trusted list. Users can still access a server using a self-signed certificate, but they lose the ability to verify that no one is operating as an imposter somewhere on the network between them and the server.
To create a self-signed certificate
1. Open a command prompt window by selecting the Start menu, selecting Programs, then Command Prompt.
2. From the command prompt, type “genslfcert CN=<unique identifier>”.
You may specify a unique identifier of your choice, such as machine name, machine location, or IP address in place of unique identifier.
3. A self-signed certificate is created in the My Certificates section of the certificates Control Panel.
This will create a self-signed certificate in the My Certificates section of the certificates control panel and a SelfSigned.cer file in My Computer which can be transferred to FTP Clients as a trusted source. Certificates may be managed through snap-ins to the Microsoft® Management Console or other third party management consoles.
A Backup should be performed after configuring the FTP server and/or creating the self-signed certificate.
GFK-2284D Chapter 2 Overview 2-25
Page 40
2
To install a certificate on an FTP Client
1. Double click the certificate. Select the General tab. The Certificate properties are displayed.
2. Click the Install Certificate button. The Certificate Import Wizard appears.
3. Click Next to continue. The Certificate Store screen appears.
4. Specify whether Windows should place the certificate in a certificate store or select another location. Click Next to continue.
The Completing the Certificate Import Wizard screen appears.
5. Click Finish to complete the installation of the certificate.
The Security Warning message appears. This message informs you Windows will automatically trust any certificate issued by this Certification Authority.
6. Click Yes to allow Windows to trust any certificate issued by this Certification Authority.
2-26 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 41
Chapter
3
Installation Procedures for Conformance
and Compliance
This chapter provides the following procedures for installing the QuickPanel View/Control unit:
Connecting a DC Power Supply 3-2 Panel Cutout 3-3 Mounting Bracket Locations 3-4 Mounting the QuickPanel View/Control in a Panel 3-5
Considerations for Choosing a Mounting Location
For compliance to NEMA 4 and 4x rating, the unit must be mounted to the
flat surface of comparably NEMA rated (IP66 equivalent) panel or enclosure.
For compliance to ATEX Directive and Class I Zone 2 hazardous locations,
the unit must be mounted in an IP66 enclosure. For ATEX applications a minimum panel thickness of 0.1” (2.54mm) is recommended.
For adequate ventilation, allow at least 3 inches of space between adjacent
equipment and all sides of the QuickPanel. Ensure that specified conditions of temperature and humidity are not exceeded.
In outdoor applications, direct sun exposure may impose increased thermal
loads on the QuickPanel leading to excessive temperature increases. Cabinet design and orientation must be carefully considered to avoid exceeding the operational temperature limits. These considerations could include shading for the QuickPanel and its cabinet with awnings or other solar opaque materials, avoiding a due East or West facing of the cabinet, providing ventilation or active cooling of the cabinet, or other methods.
GFK-2284D 3-1
Page 42
3
Bottom
Power Supply Plug
Connecting a DC Power Supply
1. Using the three screw terminals shown in the following diagram, attach a 24VDC, 48W power supply to the plug supplied with the QuickPanel
View/Control (see Appendix A, “Specifications” for power supply and
conductor size requirements).
2. Insert the plug into the power supply socket and securely tighten the attaching screws.
Note: The torque range for the attaching screws is 4–6 inch/lbs
(0.45–0.68 Nm).
3-2 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 43
3
Panel Cutout
For enclosure mounting, cut an opening in the panel according to the specifications.
Installation Notes:
To avoid gasket degradation, limit repeated insertions or removals of
the unit and retightening of the mounting clips. For full protection, always use a fresh gasket. Replacement gaskets may be ordered using part number IC754ACC12GAS.
The unit will not fit through the cutout with a compact flash (CF) card
inserted in the port, with any cables connected, or with the power supply plug inserted in the socket.
GFK-2284D Chapter 3 Installation Procedures for Conformance and Compliance 3-3
Page 44
3
Mounting Bracket Locations
To secure the QuickPanel View/Control to a panel, use the ten included mounting brackets. They hook into openings located on the top, bottom, and sides of the housing.
3-4 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 45
3
Mounting the QuickPanel View/Control in a Panel
1. Insert the unit into the panel cutout (without a CF card in the CF port).
2. Insert the hook of each mounting clamp into the housing openings as shown below.
3. Ensure that the gasket is properly seated in the bezel channel and firmly tighten the clamp screws.
Note: The torque range for the mounting clamp screws is 2.64.4 inch/lbs
(0.3–0.5 Nm).
The mounting clamps hold the unit in place by tension. No drilling is required.
Do not damage the gasket attached to the back of the QuickPanel. This gasket prevents shock hazards and damage caused by liquids accidentally entering the unit after installation.
Also, limit the number of times you remove and reinstall the unit. Too many installations may cause gasket “set” and degradation of the seal.
GFK-2284D Chapter 3 Installation Procedures for Conformance and Compliance 3-5
Page 46
Page 47
Chapter
4
Detailed Operation
Touch Screen Display 4-2
Adjusting the display brightness, configuring backlight auto turn off, calibrating the touch screen and setting the double-tap sensitivity.
Keyboard 4-10
Using an optional external keyboard and displaying the Soft Input Panel.
Communication Ports 4-13
Description and pin assignments for the COM1 and COM2 serial ports, cabling, and working with serial COM ports.
CF Port 4-25
Using the compact flash (CF) port.
Universal Serial Bus (USB) 4-27
Using the USB port.
Ethernet 4-28
Setting an IP address. Setting up access to a Windows network. Accessing a remote resource on a Windows network.
Printing 4-33
Printing on USB or Network Shared printers.
Expansion Bus 4-36
Using the expansion bus to connect optional modules.
DIP Switches 4-37
Configuring startup behavior
Memory 4-39
Adding a CF Card, changing DRAM memory allocation, installing DRAM
Other Subsystems 4-44
Accessing the Power Properties control panel, removing and replacing the internal battery, setting the real-time clock and displaying the time on the taskbar.
GFK-2284D 4-1
Page 48
4
600 pixels
800 pixels
Touch Screen Display
The QuickPanel View/Control has an integrated flat-panel display providing 16 bits per pixel for a total of 65,536 colors. The backlit 12-inch diagonal panel employs TFT technology to provide a bright operator interface.
The display supports a resolution of 800 by 600 pixels. A backlight timer is featured on all models. You can extend the backlight life by
turning off the backlight automatically.
4-2 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 49
4
To adjust the display brightness
1. In the Control Panel, double-tap Display and choose the Brightness tab. The Brightness dialog box appears.
2. Drag the Brightness slider between Lowest and Highest.
3. Tap OK to exit the control panel.
4. To save the settings, run the Backup utility. (See page 2-10.)
GFK-2284D Chapter 4 Detailed Operation 4-3
Page 50
4
To select backlight auto turn off
1. In the Control Panel, double-tap Display and choose the Backlight tab.
The Backlight dialog box appears.
2. Select Auto turn off backlight while on external power.
3. Tap OK to exit the control panel.
4. To save the settings, run the Backup utility. (See page 2-10.)
4-4 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 51
4
600 pixels
800 pixels
Touch Screen
The QuickPanel View/Control display is coupled to a resistive touch panel with 12-bit resolution. When the QuickPanel View/Control is properly calibrated, this translates into a grid of touch cells on the face of the display. A blunt stylus should always be used during calibration for greatest accuracy. During normal operation use of a finger or a soft and pliable, blunt object is recommended to preserve the maximum reliability of the touch screen.
GFK-2284D Chapter 4 Detailed Operation 4-5
Page 52
4
To calibrate the touch screen
1. In the Control Panel, double-tap Stylus.
The Stylus Properties dialog box appears.
2. Choose the Calibration tab
4-6 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 53
4
3. Tap the Recalibrate button. A cross hair target is displayed.
Note: For greatest accuracy, it is recommended that you use a blunt stylus
when calibrating the touch screen.
4. Follow the directions given to calibrate the touch screen.
GFK-2284D Chapter 4 Detailed Operation 4-7
Page 54
4
5. Tap the screen to preserve the new setting or wait out the time limit to revert to previous settings.
6. To save the settings, run the Backup utility. (See page 2-10.)
4-8 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 55
4
To set the double-tap sensitivity
1. In the Control Panel, double-tap Stylus. The Stylus Properties dialog box appears.
2. Choose the Double-Tap tab.
3. Double-tap the grid to enter a setting.
4. Double-tap the test icon to check the setting.
If the test icon doesn‘t change when you double-tap it, double-tap the grid again.
5. Tap OK to finish.
6. To save the settings, run the Backup utility. (See page 2-10.)
GFK-2284D Chapter 4 Detailed Operation 4-9
Page 56
4
Soft Input Panel icon
Keyboard
The QuickPanel View/Control can be configured to use either or both a hardware keyboard and a software emulation keyboard as operator data input devices. Typically, an external hardware keyboard is used when in a development mode, while the included Soft Input Panel is more applicable in an operational environment.
External Keyboard (optional)
Any USB keyboard compatible with the QuickPanel View/Control can be used as an input device for the unit. The USB driver for the keyboard is included with the operating system and no setup is required. To use an external keyboard, simply plug and play.
A list of compatible devices (keyboards, USB mice, compact flash cards, etc.) may be found on our Support website (refer to page iii for contact information).
Soft Input Panel
The Soft Input Panel (SIP) is a touch screen version of a standard keyboard, which can be used in place of a standard hardware keyboard.
An icon in the system tray lets you view or hide the SIP.
To show/hide the Soft Input Panel
On the system tray of the task bar, double-tap the icon. The Soft Input Panel appears/disappears.
Note: When the SIP is visible, it can be dragged around the screen by its
title bar to reveal different parts of the screen that would be obstructed from view by the SIP.
4-10 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 57
4
To display the Soft Input Panel icon in the system tray
1. In the Control Panel, double-tap Input Panel. The Input Panel Properties dialog box appears.
2. Select the Allow applications to change the input panel state check box.
3. Select or clear the Show Input Panel in system tray check box.
4. Tap OK.
5. To save the settings, run the Backup utility. (See page 2-10.)
The Soft Input Panel provides a standard QWERTY key layout with numeric keys at the top row as illustrated in the following picture.
Lower Case
GFK-2284D Chapter 4 Detailed Operation 4-11
Page 58
4
Upper case characters are accessed by pressing the SHIFT key once. This is equivalent to holding down the SHIFT key on a conventional keyboard. The SHIFT key is active while the next key is pressed then reverts back to its unselected state. The CAP key does the same thing as SHIFT but does not revert to lower case after another key is pressed. Pressing the CAP key causes the Soft Input Panel to remain in upper case mode. The CTRL and ALT keys behave the same as the SHIFT key.
Upper Case
To reset the SIP Location
If you accidentally drop the SIP off screen and can‘t drag it back on screen,
complete the following steps to reset the SIP to the center of the screen.
1. In the Control Panel, double-tap Input Panel. The Input Panel Properties dialog box, shown on page 4-11), appears.
2. Click Reset SIP location.
External Mouse (optional)
Any USB mouse compatible with the QuickPanel View/Control can be used as an input device for the unit. The USB driver for the mouse is included with the operating system and no setup is required. To use an external mouse, simply plug it into the appropriate port.
A list of mice (and other devices) that have been tested and are compatible can be found by visiting our Support website. In the ―Technical Resources ―Browse by Product‖ section of the page, choose the Operator Interface Product Category, and the QuickPanel View Product Name.
4-12 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 59
4
1 GND - Frame Ground
14 VCC -5VDC, 0.5A
2 TX - (EIA232C)
15 TXB (EIA485)
3 RX - (EIA232C)
16 RXB (EIA485)
4 RTS - (EIA232C)
17 n/c
5 CTS -(EIA232C)
18 CSB (EIA485)
6 DSR - (EIA232C)
19 ERB (EIA485)
7 SG - Signal Ground
20 DTR (EIA232C)
8 DCD - (EIA232C)
21 CSA (EIA485)
9 TRMRXB (EIA485)
22 ERA (EIA485)
10 RXA (EIA485)
23 n/c
11 TXA (EIA485)
24 n/c
12 n/c
25 n/c
13 n/c
Communication Ports
The QuickPanel View/Control has two serial data communication ports, COM1 and COM2.
COM1- Serial
The COM1 port is a general purpose bidirectional serial data channel that supports the EIA232C and EIA485 electrical standards. The COM1 port can be accessed and configured:
as a direct or dial-up remote networking connection.  as the port used by a terminal session (modem link only).  from a user-created application utility.
A connection can be configured to reside on a network supporting a TCP/IP protocol.
A DB25S (female) connector, mounted on the bottom of the enclosure, provides standard signals as described in the following table.
Note: Pin 14 is fused with a field-replaceable, 1.0A fast-blow fuse.
GFK-2284D Chapter 4 Detailed Operation 4-13
Page 60
4
Connections
Connect nodes in a daisy chain fashion. Do not connect in other arrangements, especially "star." The standards do not specify the maximum number of nodes or devices that can be connected to a TIA/EIA 422 or 485 network. Instead, the standards limit the number of electrical connections by specifying that a maximum of 32 unit loads may be connected. The QuickPanel View or QuickPanel Control presents one unit load.
Interconnect media
Always use twisted pair cabling and group complimentary signals into conductor pairs; TXA with TXB, for example. Use a cable with a characteristic impedance of 100 ohms to 120 ohms. A wire gauge of 24 AWG is commonly used. Maximum cable length is 4,000' (1,219.2m), but may be less due to cable impedance, connection quality, data rates, and other factors.
Termination
Always provide proper termination at each end of the 422/485 network. The QuickPanel View provides built-in termination resistance when pin #9 (TRMRXB) is connected to pin #10 (RXA).
Caution: Do not terminate every node. Only terminate the end nodes.
Recommended Cabling for TIA/EIA422 or TIA/EIA485
The COM1 port on the QuickPanel View/QuickPanel Control provides connections to devices that support either TIA/EIA422 or TIA/EIA485. These electrical standards specify a differential signaling technique that provides high data rates, long distances and good noise rejection. The standards do not address signal encoding (protocol), connectors, or cabling. However, certain characteristics of these devices‘ interfaces should be considered to ensure reliable connections.
4-14 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 61
4
Grounding
A signal return path between transmitting and receiving devices must be provided. This return path is separate from the Rx and Tx data lines and the other 422/485 signals supported by the QuickPanel View/QuickPanel Control, and may be provided by a separate conductor in the cable. Connect both ends of the signal return conductor to Signal Ground (pin #7). Shielding or use of a twisted pair for this connection is not necessary.
For installations where all devices are in the same cabinet and have the same ground potential between devices, connecting Signal Ground between all the devices on the 422/485 network is adequate to ensure proper voltage levels at the devices.
However, if there is a difference in ground potential between devices, such as when the devices are in widely separated cabinets, signal grounds on a 422/485 network should not be tied together. The cable shield and signal ground should be connected together at only one device, closest to the earth ground connection.
The signal and frame grounds of the QuickPanel View/QuickPanel Control are capacitively coupled, but in some devices these ground references are connected together. Connect Signal Ground (pin #7) to Frame Ground (pin #1) and then to earth ground on the QuickPanel View/QuickPanel Control only in the circumstance where the other devices separate their signal and frame grounds and the QuickPanel View/QuickPanel Control is the only device with frame and signal ground connected to earth ground.
Shielding
Shielded cable is required for compliance with CE Mark and FCC requirements. The cable shield should be connected to the metal connector shell or by pin 1 of the QuickPanel 25-pin serial connector. Shield and signal ground (pin 7 of the 25pin connector or pin 5 of the 9-pin serial connector) should not be connected directly together.
Caution
GFK-2284D Chapter 4 Detailed Operation 4-15
Do not connect Signal Ground (pin #7) to Frame Ground (pin #1) on the QuickPanel View/QuickPanel Control, except in the specific and limited circumstances noted in the Grounding section above.
Page 62
4
1 n/c
2 RX
3 TX
4 n/c
5 SG - Signal Ground
6 n/c
7 RTS
8 CTS
9 n/c
Shielding
Shielded cable is required for compliance with CE Mark and FCC requirements. The cable shield should be connected to the metal connector shell. Shield and signal ground (pin 5 of the 9-pin serial connector) should not be connected directly together.
COM2 - Serial
The COM2 port is a general-purpose bidirectional serial data channel that supports the EIA232C electrical standards.
A DB9P (male) connector, mounted on the bottom of the enclosure, provides standard signals as described in the following table.
4-16 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 63
4
Working with COM ports
To add a new remote networking connection
1. From the
Start menu, tap Settings and then Network and Dial-
up Connections.
The Connection window appears.
2. Double-tap Make New Connection. The Make New Connection window appears.
3. Type a name for the new connection.
4. Choose a connection type. If you are configuring a modem, choose
Dial-Up Connection. If you have a device, select Direct Connection.
GFK-2284D Chapter 4 Detailed Operation 4-17
Page 64
4
or
5. Tap Next. The Modem or Device dialog box appears, depending on the connection type.
6. From the list, choose the device or modem you want to use. (If a serial CF card is inserted, it is available in the device list.)
You can configure your device or TCP/IP Settings at this time if you wish.
7. Tap Finish for direct connection (Device dialog box) or Next for dial-up (Modem dialog box).
If you are adding a dial-up connection the following dialog box appears.
8. Type the destination Country/region code, Area code, and Phone number in the appropriate boxes.
9. Select or clear the Force Long Distance or Force Local check boxes.
10. Tap Finish.
4-18 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 65
4
or
To add a virtual private network or PPP over Ethernet
1. From the
Start menu, tap Settings and then Network and Dial-
up Connections.
The Connection window appears.
2. Double-tap Make New Connection. The Make New Connection window appears.
3. Type a name for the new connection.
4. Choose a connection type. Select Virtual Private Network to configure
a VPN connection. Select PPP over Ethernet for a PPPoE connection.
5. Tap Next. The VPN or PPPoE Connection window appears, depending
on the connection type.
GFK-2284D Chapter 4 Detailed Operation 4-19
Page 66
4
6. Enter the Host Name or IP address for a VPN connection, or a PPPoE Service Name for a PPPoE connection.
You can configure your TCP/IP Settings at this time if you wish.
7. Tap Finish.
To change the default device properties
1. From either the Device or Modem dialog box, tap Configure.
The Device Properties dialog box appears.
2. In the Port Settings tab, choose settings for all connection preferences.
3. If the connection is for terminal emulation, select or clear the terminal­related check boxes.
You can use the QuickPanel View/Control to emulate a terminal attached via a modem link (Hayes compatible) to COM1. A terminal emulation definition is added as a unique session.
4-20 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 67
4
To change the default TCP/IP settings
1. Obtain correct TCP/IP settings from your network administrator.
2. From the Device, Modem, PPPoE Connection, or VPN Connection dialog box, tap TCP/IP Settings.
The TCP/IP Settings dialog box appears.
3. Clear the Use server-assigned IP address check box.
4. Enter the TCP/IP settings from your network administrator and then click OK.
GFK-2284D Chapter 4 Detailed Operation 4-21
Page 68
4
To add a terminal session
1. From the
Start menu, tap Programs, then Communication, and
then tap Terminal.
The Terminal window appears.
2. Double tap Make New Session. The Session Properties dialog box (Communications tab) appears.
3. In the Session Name box, type a name for your session.
4. Enter the Country Code, Area Code and Telephone number of the
remote modem you will connect to.
4-22 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 69
4
5. Tap the Emulation tab and choose an emulation type (DEC-VT-100 or TTY (Generic)).
6. From the Code page selection box, select the coding type to employ.
7. Select the Inbound and /or Outbound check boxes to add LF characters to each CR.
8. Select the Vertical and/or Horizontal check boxes to specify automatic scrolling.
9. Tap OK.
10. The new session is added to the Session window.
11. To save the settings, run the Backup utility. (See page 2-10.)
GFK-2284D Chapter 4 Detailed Operation 4-23
Page 70
4
To start a terminal session
1. From the
Start menu, tap Programs, then Communication, and
choose Terminal.
The Terminal window appears.
2. Double-tap the session you want.
4-24 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 71
4
CF Port
To enhance the QuickPanel View/Control‘s capabilities with additional flash
memory, the unit is equipped with a CF (Compact Flash) Type 2 port on its side.
A CF card is inserted in this port with the card‘s front facing the back of the unit. (The narrow side slot on the card should be toward the bottom.)
Note: For full protection from electrostatic discharge, peel off the paper label
on the side of the CF card facing the bezel to allow contact between
the card and the internal frame ground contacts on the CF connector. The card should slide in easily. To avoid damage, do not force it. The Copy Project to Flash Card utility, described in chapter 2 lets you transfer
Proficy Machine Edition projects between QuickPanel View/Control units using CF Cards.
The CF port in the QuickPanel View/Control supports both 3.3V CF cards and 5V CF cards.
GFK-2284D Chapter 4 Detailed Operation 4-25
Page 72
4
No CF cards are supplied with the QuickPanel View/Control. A list of cards (and other devices) that have been tested and are compatible can be found by visiting the Support website, selecting the Operator Interface category, and then selecting the QuickPanel View product name.
An optional CF card may be ordered using part number IC754ACC0512MEM.
Caution
Do not remove power while the system is writing to the CF card, such as when copying a Proficy Machine Edition project. Removing power while writing may lead to data loss and file or CF card corruption. To ensure the system completes writing to flash and closes all files after file operations that were activated from the desktop, allow the Windows file progress dialog to finish or indicate the operation is complete. If the View or Control applications are running, see “Shutdown” in chapter 1.
4-26 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 73
4
1
5V+
2
Data-
3
Data+
4
GND
Universal Serial Bus (USB)
The QuickPanel View/Control has two full-speed USB v1.1 host ports. A variety of third-party USB peripheral devices are available.
Each connected USB device requires a specific driver. The driver supplied with the QuickPanel View/Control is for optional keyboard or mouse support – other devices require the installation of custom driver software.
A list of compatible devices (keyboards, USB mice, compact flash cards, USB memory stick, etc.) may be found on our Support website.
Note: These USB ports are defined as maintenance ports and are
intended to be temporary connections used for configuration and upload/download of software or data.
Use of a device in the USB port may compromise CE Mark and UL certifications. Before using an application requiring the use of a USB device, verify that the USB device installed in the QuickPanel View/Control meets the desired agency certifications.
Warning
For compliance to UL1604, do not connect or disconnect
while power is applied unless the area is known to be
nonhazardous.
GFK-2284D Chapter 4 Detailed Operation 4-27
Page 74
4
LAN1: 10/100Mb
LAN2: 10/100Mb
Ethernet Ports
Activity LED
(On: Packet received
or transmitted)
Link LED
(On: Channel
connected OK)
1
TX_D1 +
2
TX_D1 -
3
RX_D2 +
4
NC 5 NC 6 RX_D2 -
7
NC 8 NC
Ethernet
The QuickPanel View/Control is equipped with two auto-negotiate, full or half duplex Ethernet ports (IEEE802.3). The auto-negotiate feature is not configurable on the QuickPanel, therefore all devices on the network to which the QuickPanel is attached should also be in auto-negotiate mode to ensure proper network communications.
You can connect an Ethernet network cable (unshielded, twisted pair, UTP CAT 5) to the unit via the RJ45 connector on the bottom of the enclosure. LED indicators on the port indicate channel status. Access to the ports is possible either by Windows CE network communications, or by your custom application. The following diagram shows the location, orientation, and pin out of the Ethernet ports.
4-28 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 75
4
The QuickPanel View/Control provides two methods for setting an IP address:
DHCP (Dynamic Host Configuration Protocol). There must be a
DHCP server on the connected network for a valid IP address to be
assigned. Contact your network administrator to ensure correct DHCP
server configuration.
Manual method. You uniquely specify the numeric addresses for the
QuickPanel View/Control, the Subnet Mask, and the Default Gateway
(if applicable). DHCP is the default on LAN1. The default on LAN2 is Manual with a setting of
IP address 192.0.0.1 subnet mask of 255.255.255.0 and no gateway.
Note: Use a crossover cable to connect the QuickPanel View/Control
directly to a PC. When connecting to a LAN HUB, use a straight-through cable. Contact your network administrator for further information.
To set an IP address
1. From the Control Panel, tap Network and Dial-up Connections.
The Connection window appears.
2. Select a connection and choose Properties. The Built-in Ethernet Port Settings dialog box appears.
GFK-2284D Chapter 4 Detailed Operation 4-29
Page 76
4
3. Select a method:
Obtain an IP address via DHCP (automatic).  Specify an IP address (manual).
4. Enter the IP Address, Subnet Mask and Default Gateway numbers obtained from your network administrator (manual method only).
5. Tap OK.
6. To save the settings, run the Backup utility. (See page 2-10.)
If the DHCP method was selected, the network server will assign an IP address while the QuickPanel View/Control is initializing. (You must be connected to the network).
After setting an IP address for the QuickPanel View/Control, you can access any network drives or shared resources for which you have permission.
4-30 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 77
4
To set up access to a Windows network
1. In the Control Panel, double-tap System. The System Properties dialog box appears.
2. On the Device Name tab, in the Device name box, type a unique name for your QuickPanel View/Control. In the Device description box, type a description.
3. Tap OK.
4. In the Control Panel, double-tap Owner. The Owner Properties dialog box appears.
GFK-2284D Chapter 4 Detailed Operation 4-31
Page 78
4
5. On the Network ID tab, type your User name, Password and Domain.
6. Tap OK.
7. To save the settings, run the Backup utility. (See page 2-10.)
Using Windows CE Explorer, you can now access anything on your local network for which you have permission.
To access a remote resource on a Windows network
1. Start Windows Explorer. The Explorer window appears.
2. Type in the Address box, or choose from a list, the path to a remote resource.
For example ‗\\MyRemoteComputer\MyFolder‘ specifies the folder named ‗MyFolder‘ on a computer with the name ‗MyRemoteComputer‘.
3. Press ENTER.
The resource specified is displayed as a collection of files and folders. It can take a few moments to retrieve the data from your local network.
Note: You can use the NET command from the command prompt to map
a network resource to the QuickPanel View/Control for frequent access. The resource then appears in the Network folder.
4-32 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 79
4
Printing
Warning
USB connected printers will violate the electrical compliance ratings. They can only be used for maintenance and are not supported as a standard service.
Please see the notes in the USB section for important information about compliance and certification while using USB devices.
The QuickPanel View/Control supports printing to PCL v5 compatible laser and inkjet printers. The printer can be connected by either USB (on models with USB ports) or by a network shared printer over Ethernet. The control panel applet Printers is used to configure the port connection and other general printing options.
For fastest printing performance, select draft mode and portrait orientation, and disable color for print settings. These setting also minimize the amount of memory needed to print a document.
The built in driver has a document spooling function to improve GUI performance. This spooler supports only one document at a time. However, on an Ethernet connected printer, the print server usually supports multiple documents in its queue. Windows CE does not support the ability to observe what documents are queued up at the printer.
For a list of printers known to work on the QuickPanel View/Control, refer to document KB8259 on our Support website (refer to page iii for contact information).
GFK-2284D Chapter 4 Detailed Operation 4-33
Page 80
4
USB Printers
Generic PCL printers are supported by the built in driver. Many of the currently available printers use a proprietary driver and will not operate with the generic driver.
Not all USB printers will be correctly identified by the QuickPanel when the printer is connected. The port LPT1 will show on the printer configuration dialog‘s port list when the USB printer is correctly detected.
When an unsupported USB printer is connected to the QuickPanel View/Control, a pop-up dialog box prompts for the USB driver to use. Supported printers will not show this dialog. Just close the dialog if it appears and choose a different printer. Alternatively, you may be able to set the printer up as a network shared printer connected to another computer on your Ethernet network.
The port for the USB connected printer does not show on the printer
configuration dialog‘s port list unless the USB printer is connected and
compatible. The port LPT1: will be shown in the port list when it is available. To connect to the USB printer, select LPT1: from the Ports list of the Printers
configuration dialog. Leave the printer type set to either PCL Laser or PCL Inkjet, as appropriate.
Printer-side errors are displayed in pop-up dialogs that need to be acknowledged before the unit can continue operation. Generally you will be given the option to retry printing the document, or to cancel the remainder of the document.
4-34 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 81
4
Network Shared Printers
The QuickPanel View/Control can connect to a PCL printer that is hosted by another computer that supports the Ethernet SMB protocol, or directly to a printer supporting the LPR/LPD protocol.
Printer sharing in Microsoft Windows OS supports the SMB protocol. To connect to the printer, select Network from the Ports list of the Printers
configuration dialog, and then fill in a network path in the Net Path field. Printers may support Server Message Block (SMB) or Line Printer Remote
(LPR) protocols. To determine which protocols your printer supports, refer to the documentation provided with the printer.
For an SMB compatible network printer, use the UNC syntax:
\\server_name\printer_name. Windows CE does not support use of the server's IP for the server_name portion of the UNC.
Server_name is the text name of the printer server. An IP address does not work here.
Printer_name is the printer port share name. Do not confuse the port share name with the friendly printer name that may be displayed in a Windows desktop printer configuration. To determine the share name, either ask your IT department, or look it up from a Windows PC that can print to the printer you wish to use. The share name will show on the sharing tab of the printer properties dialog.
For an LPR compatible network printer, use the syntax:
LPR\printer_name or LPR\printer_ip_address.
If connection to the shared printer requires domain credentials, and the credentials have not yet been set, you will be prompted to fill in the credentials when you next attempt to print. You have the choice of saving the credentials to be used from then on, or to enter them every time.
Printer errors are not visible on the QuickPanel View/Control.
GFK-2284D Chapter 4 Detailed Operation 4-35
Page 82
4
Back (open)
Expansion Bus
Note: To ensure compliance to CE
Mark, the mounting screws must be used when installing an expansion card.
Expansion Bus
An expansion bus is included with the QuickPanel View/Control, and optional modules that mount directly to it are available. For more information on expansion modules, contact your distributor.
The expansion bus connectors are accessed by opening the back of the unit.
Caution
Disconnect power from your DC power supply before opening
the QuickPanel View/Control. Working on a “live” unit may
result in damage to equipment and injury to personnel. Always use anti-static precautions (i.e. grounded wrist strap) when accessing the interior of the unit.
Caution
Ensure all pins are properly aligned when inserting expansion cards. Misalignment could cause damage to the QuickPanel View/Control and/or the expansion card.
Caution
Do not allow conductive material, liquid or solid, to contact the electronics of the QuickPanel.
4-36 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 83
4
DIP Switches
The QuickPanel View/Control is equipped with four DIP switches that control
separate functions. DIP switches are set to ―OFF‖ by default in the factory. DIP
switch 2 is the Force Startup switch. Turning this switch on forces the startup applications to run when the operating system is started.
When the switch is set to ―OFF‖, the QuickPanel View/Control operates
normally, displaying the startup splash screen. You can skip running the startup
applications by tapping the ―Don‘t run StartUp Programs‖ button on the startup
splash screen.
When the switch is set to ―ON‖, the startup programs are forced to run and the ―Don‘t run Startup Programs‖ button is not available on the startup splash
screen. Note: Do not adjust switches other than switch 2. They are reserved for
factory functions. Also note that the ―Off‖ position of the switches is
toward the DIMM connector, ―On‖ toward the COM1 connector.
GFK-2284D Chapter 4 Detailed Operation 4-37
Page 84
4
To configure startup behavior
Caution
Disconnect power from your DC power supply before opening
the QuickPanel View/Control. Working on a “live” unit may
result in damage to equipment and injury to personnel. Always use anti-static precautions (i.e. grounded wrist strap) when accessing the interior of the unit.
Caution
Do not allow conductive material, either liquid or solid, to contact the electronics of the QuickPanel.
1. Open the back cover of the QuickPanel View/Control.
2. Locate the DIP switches and set DIP switch 2 to ―ON‖. The startup applications are now forced.
Note: Do not adjust the other switches. They are reserved for factory
functions.
4-38 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 85
4
Memory
The QuickPanel View/Control supports a variety of memory subsystems to ensure the requirements of your application are met. All system memory is tied
directly to the microprocessor‘s address and data busses for fastest access. To
increase DRAM by up to 64 MB, a 100-pin DIMM memory expansion slot is also included.
Flash Memory
This 64 MB block of non-volatile memory is the main long-term program storage for the QuickPanel View/Control, operating like a virtual hard drive from the point of view of Windows CE. It is divided into two areas, of which only one
is accessible from Windows CE Explorer. The
Flash Storage folder represents a 48 MB block of memory available for long-term storage of user application programs. Another 16MB block is used to store the Windows CE operating system, and is not directly accessible from Windows CE Explorer.
The operating system and all user application programs are transferred from Flash to DRAM for execution. Any user additions to the Windows folder are
retained in
Flash Storage when the Backup utility is run.
FLASH memory has a limited write-cycle lifetime. That is, the physical memory devices wear out after approximately 100,000 cycles (minimum), so it is advisable to limit file operations such as copy, delete, etc.
The write cycle is much slower for FLASH than it is for other portions of RAM, therefore FLASH is not recommended for the storage of program variables, or any data items whose values are dynamic.
Flash memory can optionally be added with an external flash device such as a CF card or USB thumb drive. These devices will appear as the Storage folder or
USB Storage, respectively.
PCFlash
GFK-2284D Chapter 4 Detailed Operation 4-39
Page 86
4
Caution
Do not remove power while the system is writing to flash memory, such as when downloading a Proficy Machine Edition project. Removing power while writing may lead to data loss and file system corruption. To ensure the system completes writing to flash and closes all files, see “Shutdown” in chapter 1.
To add Flash memory with a CF Card
Insert a Compact Flash card into CF Port (see page 4-25).
The unit immediately reads the new secondary storage. If the disk requires formatting, you will be prompted to do so.
New memory appears in Windows CE Explorer as
PCFlash
Storage.
External flash memory devices are named after their types of connection and order of attachment. For example, if you connect two flash memory devices, one via the CF port and one via the FieldBus connector, the first device connected is named PCFlash Storage, the second PCFlash Storage2. At powerup, a CF port device is recognized and named first. Otherwise name depends on connection order.
SRAM Memory
This 512 KB block of static RAM is battery-backed to provide data retention through a power cycle. This memory block is shared by the operating system and user applications. A portion of the SRAM memory operates as a virtual hard drive and is accessible from the Windows CE Explorer. It is represented
as the file in this folder and store critical program data in that file.
The portions of SRAM used by the operating system and by user applications varies between models.
SRAM Storage folder. A typical application program would create a
4-40 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 87
4
DRAM Memory
The QuickPanel is equipped with 64 MB of dynamic RAM. Part of the DRAM (16 MB) is reserved for the Windows CE operating system and is not accessible by user applications. The remaining 48 MB is split between two functions: an object store for temporary file storage, and the main memory for running programs.
Typically, compressed programs stored in FLASH are expanded and moved to DRAM for execution. Temporary storage of program variables or data files is also provided by DRAMany data stored in DRAM will not be retained through a power cycle or reboot.
The split between program memory and storage memory may be adjusted as necessary to make more room for one or the other, depending on your specific application needs. For example, if you find that an application is short of memory, use the System Properties dialog box to alter DRAM memory allocation.
Caution
Setting Program Memory too low may prevent additional applications from starting, or may cause currently running applications to fail due to lack of memory. Setting Storage Memory too low may prevent the saving of files into the object store portion of the file system, which may also cause application failures.
GFK-2284D Chapter 4 Detailed Operation 4-41
Page 88
4
To change the DRAM memory allocation
1. In the Control Panel, double-tap System. The System Properties dialog box appears.
2. On the Memory tab, drag the slider to divide the DRAM into Storage and Program memory.
The amount of memory allocated to and used by each area is shown on the dialog box. The amount of memory allocated to and used by each area is displayed numerically. The blue bar indicates the current amount of unallocated DRAM and determines the boundaries within which the slider can move.
3. Tap OK to apply the new setting.
4. To save the settings, run the Backup utility. (See page 2-10.)
Boot Loader ROM
The Boot Loader ROM provides 512 KB of non-volatile storage for the
QuickPanel View/Control‘s initialization program. This program configures the QuickPanel View/Control hardware then starts the operating system‘s
execution. This memory is not accessible from Windows CE Explorer, nor should any attempts be made to modify the contents of this ROM.
4-42 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 89
4
Memory Expansion Slot
Rear (open)
Memory Expansion Slot
The QuickPanel View/Control is equipped with a 100-pin DIMM memory expansion slot, which lets you increase DRAM to a total of 128MB.
Caution
Disconnect power from your DC power supply before opening
the QuickPanel View/Control. Working on a “live” unit may
result in damage to equipment and injury to personnel. Always use anti-static precautions when accessing the interior of the QuickPanel View/Control.
Caution
Do not allow conductive material, liquid or solid, to contact the electronics of the QuickPanel.
To install additional DRAM
1. Disconnect AC power from the DC supply.
2. With a small screwdriver, carefully remove the top rear access cover.
3. Insert the new DIMM carefully into the expansion slot, noting the orientation of the pin locators. When the DIMM is fully seated, lift each side clip until it clicks into place.
4. Snap the access cover back into place.
GFK-2284D Chapter 4 Detailed Operation 4-43
Page 90
4
Other Subsystems
Power Management
The QuickPanel View/Control‘s Power Properties control panel displays the
status of the backup battery. The Battery Very Low Or Missing icon appears in the taskbar when the battery is either missing or very low.
To access the Power Properties control panel
1. In the Control Panel, double-tap Power. The Power Properties dialog box appears.
4-44 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 91
4
Rear (open)
Internal Battery
Battery Backup
Auxiliary backup power for the real-time clock and SRAM is provided by a non-rechargeable, internal lithium battery (+3VDC, BR2032), ensuring that no
loss of data occurs when the main DC supply is removed. Backup power is enabled or disabled by installing or removing the battery, accessed via the rear panel as shown in the following illustration.
Caution
Disconnect the AC power from your DC power supply before
opening the QuickPanel View/Control. Working on a “live”
unit may result in damage to equipment and injury to personnel. Always use anti-static precautions when accessing the interior of the QuickPanel View/Control.
Caution
Do not allow conductive material, liquid or solid, to contact the electronics of the QuickPanel.
GFK-2284D Chapter 4 Detailed Operation 4-45
Page 92
4
To remove the internal battery
1. Disconnect AC power from the DC supply.
2. Open the rear access panel.
3. Release the battery by gently lifting it from the completely exposed side, past the small protrusions. To avoid breaking the battery retainer clips, do not apply excessive upward pressure.
4. Slide the battery out of its carrier, noting the arrow on the carrier indicating the direction of removal.
To install a new battery
1. Disconnect AC power from the DC supply.
2. Open the rear access panel.
Note: Battery must be installed with positive ( + ) side up.
3. To install the battery, insert one side of the battery into the upper side of the battery clip, then press the other side into the clip until snaps into place.
Warning
Replace battery with Panasonic BR2032 only. Use of another battery may present a risk of fire or explosion.
Warning
Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire.
4-46 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 93
4
Real-time Clock
The QuickPanel View/Control has a programmable real-time clock capable of reporting the current time in Year/Month/Day/Hour/Minute/Second. The time is set from the Windows CE interface and retained through a power cycle if battery backup is available. Daylight saving time is enabled by a check box within the dialog box. The time can be displayed in the system tray on the task bar.
To set the real-time clock
1. In the Control Panel, double-tap Date/Time.
The Date/Time Properties dialog box appears.
Note: Tap Apply after making changes in any box.
2. To modify the date, select the Date/Time tab.
3. Tap the year to choose a new year; tap the month to choose a new month.
4. Tap a date to specify the day of month.
5. From the Time Zone box, choose your zone.
GFK-2284D Chapter 4 Detailed Operation 4-47
Page 94
4
Clock Display
6. Select Auto Adjust DST to configure the clock to automatically compensate for daylight savings time.
7. In the Current Time box, adjust the hours, minutes and seconds.
8. Tap OK to finish.
9. To save the settings, run the Backup utility. (See page 2-10.)
To display the time on the taskbar
1. From the
Start menu, choose Settings and then Taskbar and
Start Menu Properties.
The Taskbar Properties dialog box appears.
1. On the Taskbar Options tab, select Show Clock.
2. Tap OK.
An hours and minutes display now appears in the taskbar.
4-48 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 95
4
Configuring SNTP
There are two levels of Network Time Protocol (NTP) time servers available on the Internet.
First-level time servers are primarily intended to act as source time servers for second-level time servers. First-level time servers may also be capable of providing mission-critical time services. Some first-level time servers may have a restricted access policy.
Second-level time servers are intended for general SNTP time service needs and usually enable public access. It is recommended that you use second-level time servers for normal SNTP time server configuration because they are normally located on a closer network that can produce faster updates.
It is recommended that you research any time server selection to ensure that it can meet your specific time server requirements. More information and a list of SNTP time servers can be found at http://support.microsoft.com/kb/262680/.
If the time on the time server is more than the threshold value away from the current time on the QuickPanel View/Control, then the time is not updated. Setting the Threshold to 0 tells the utility to always accept the time from the server. This setting would be useful in a case where the backup battery has died and the QuickPanel View/Control was power cycled, since the internal clock would have reset back to January 1, 1980 12:00 am.
GFK-2284D Chapter 4 Detailed Operation 4-49
Page 96
4
To set SNTP
1. In the Control Panel, double-tap Date/Time.
The Date/Time Properties dialog box appears.
Note: Tap Apply after making changes in any box.
2. To add or modify SNTP settings, select the SNTP tab.
3. To enable SNTP, ensure the Enable SNTP check box is selected.
4. Enter the time server name in the Server(s) field.
5. Set the Refresh, Retry, and Threshold parameters.
6. Tap Update Now to update SNTP settings immediately.
7. Tap OK to finish.
8. To save the settings, run the Backup utility. (See page 2-10.)
4-50 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 97
Enclosure dimensions (actual – see ―Panel Cutout‖ in chapter 3 for cutout dimensions)
Height: 8.93 in (226.8 mm)
Width: 11.85 in (301.1 mm)
Depth: 2.37 in (60.1 mm)
Bezel dimensions
Height: 10.34 in (262.6 mm)
Width: 13.26 in. (336.8 mm)
Depth: 0.38 in (9.7 mm)
Weight
5.2 lb (2.36 kg)
Input Voltage
12 VDC (@ ±20% regulated power supply); or 24 VDC (@ ±20% regulated power supply)
Power Dip Tolerance
-30% nominal input voltage, 10msec.
Insulation Resistance
>200Mohm @ 1000V frame ground to 0V >200Mohm @ 1000V frame ground to 24
Real Power
48W
Power Supply Conductor Size
12 to 18 AWG For compliance to CE Mark, the isolated frame
ground must be connected. Recommended frame ground connection is via the
shortest possible route, using 14 AWG.
Connector (Vendor, p/n)
Phoenix Contact, 1777992
Appendix
A
Specifications
See page A-6 for a list of agency approvals for environmental service and safety.
Physical
DC Power
GFK-2284D A-1
Page 98
A
Size
12" (30.5 cm) diagonal
Colors
65536 (16 bits/pixel)
Resolution
800 x 600
Fabrication
TFT
Backlight
Cold Cathode Fluorescent (CCFL) -rated half life: 50,000 hours.
Note: Backlight is not field replaceable.
Luminance
400 NITS
Bezel Material
Valox 3706 For material specifications, visit
www.gepolymerland.com
Membrane Material
Lexan HP60
For material specifications, visit gestructuredproducts.com
LEDs
Bottom
Power status indicator (green with power applied, red if either backlight fails)
Top
Programmable tri-color (green, red, amber)
Type
Resistive, 12 bit
Resolution (after calibration)
X axis: 800 cells
Y axis: 600 cells
(after calibration)
Display
Front Panel
Touch Screen
A-2 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Page 99
A
Processor
XScale
Clock speed
400 MHz
Flash
64 MB
SRAM
512 KB (Power off retention is the life of the battery)
DRAM
64 MB
ROM
512 KB (Boot loader)
Form Factor
100 pin DIMM
Memory Type
SDRAM
Maximum DRAM
64 MB
Maximum Devices per Module
Four
Bus Width
32 bits
Bus Speed
100 MHz or faster
Voltage
3.3 VDC
CAS Latency
CL=3
Refresh Type
Self
Refresh Cycle Time
64 ms maximum
Error Correction
Non-ECC
Error Detection
No parity
Buffering
None
Device Row Addressing
12 Address Lines (A0 to A11)
Expansion Memory Catalog Number
64 MB, IC754ACC64MEM 32 MB, IC754ACC32MEM
CPU
Memory
Memory Expansion Slot
GFK-2284D Appendix A Specifications A-3
Page 100
A
Compact Flash Memory
One slot (Type I/II), supports 3.3V and 5V cards
Optional CF Card Catalog Number
512 MB, IC754ACC0512MEM
FieldBus
One slot
Universal Serial Bus (USB) (2)
V1.1 compatible
Ethernet (LAN1 and LAN2)
IEEE 802.3
10 BaseT/100 Base TX
Auto-negotiate
Full or half duplex
RJ45 connectors
Two status LEDs per connector
Maximum cable length: 100m
Serial COM1
EIA232C/EIA485, DP25S (female)
Speed
300 bps -115200 bps
Mounting hardware
M2.6 jackscrew
Fuse
1.0A, 125V fast blow cartridge type Littlefuse part #154001
Serial COM2
EIA232C, DP9P (male)
Speed
300 bps -115200 bps
Mounting hardware
#4-40 screw
Expansion Ports
Communication Ports
A-4 12" QuickPanel* View & QuickPanel Control Loaded Color TFT – December 2010 GFK-2284D
Loading...