GE GXSF39E, GXSF35E User Manual

Water Softening
system
Safety Information . . . . . . . . . .2
Installation Instructions . .3–12
Step-by-step instructions . . .6–12

Operating Instructions

Breaking a salt bridge . . . . . . .14
Cleaning the nozzle and
Features . . . . . . . . . . . . . . . . . .15
Service . . . . . . . . . . . . .13, 16–18
Water softener system . . . .13–18
Care and Cleaning . . . . . . . .19
Troubleshooting Tips . . . .20–22

Consumer Support

Consumer Support . .Back Cover
Parts list/catalog . . . . . . . .24–27
Warranty (U.S.) . . . . . . . . . . . .28
Warranty (Canada) . . . . . . . . .29
Modelos GXSF35E, GXSF39E
Manual del Propietario e
Instrucciones de Instalación
La sección en español empieza en la página 31
Sistema Suavizante
de Agua
www.GEAppliances.com
7247174 215C1173P010 49-50151 02-05 JR
Write the model and serial numbers here:
Model # ____________________________
Serial # ____________________________
To find these numbers, lift the cover and look on the rim below the control panel.
Models GXSF35E, GXSF39E
Owner’s Manual &
Installation Instructions
Water Softening
System
System tested and certified by NSF International against NSF/ANSI Standard 44 for the chemical reduction claims specified on the performance data sheet.
Sistema probado y certificado por NSF International contra norma 44 de NSF/ANSI para las afirmaciones de reducción de los productos químicos especificadas en la hoja de datos de funcionamiento.
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
SAFETY PRECAUTIONS
Check and comply with your state and local
codes. You must follow these guidelines.
Use care when handling the water softening
system. Do not turn upside down, drop, drag or set on sharp protrusions.
Water softening systems using sodium chloride
(salt) for recharge add sodium to the water.
Persons on sodium restricted diets should consider the added sodium as part of their overall intake. Potassium chloride can be used as an alternative to sodium chloride in your softener.
The water softening system works on 24 volt-60 Hz electrical power only. Be sure to use only the
included transformer.
Transformer must be plugged into an indoor
120 volt, grounded outlet only.
Use clean water softening salts only, at least
99.5% pure. NUGGET, PELLET or coarse SOLAR salts are recommended. Do not use rock, block, granulated or ice cream making salts. They contain dirt and sediments, or mush and cake, and will create maintenance problems.
Keep the salt hole cover in place on the softener
unless servicing the unit or refilling with salt.
WARNING: Do not use with water that is
microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
PROPER INSTALLATION
Install or store where it will not be exposed to
temperatures below freezing or exposed to any type of weather. Water freezing in the system will break it. Do not attempt to treat water over 100°F.
Do not install in direct sunlight. Excessive sun or
heat may cause distortion or other damage to non-metallic parts.
Properly ground to conform with all governing
codes and ordinances.
Use only lead-free solder and flux for all sweat-
solder connections, as required by state and federal codes.
The water softening system requires a minimum water flow of three gallons per minute at the inlet. Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve to reduce the flow if necessary.
Softener resins may degrade in the presence of chlorine above 1 ppm. If you have chlorine in excess of this amount, you may experience reduced life of the resin. In these conditions, you may wish to consider purchasing a GE point-of-entry household filtration system with a chlorine reducing filter.
WARNING: Discard all unused parts
and packaging material after installation. Small parts remaining after the installation could be a choke hazard.
This water softening system must be properly installed and located in accordance with the Installation Instructions before it is used.
2
For your safety, the information in this manual must be followed to minimize the risk of electric shock, property damage or personal injury.
WARNING!
3
CAUTION: Certain plumbing skills are needed for installation. If you are unsure about
any part of the installation of this product, consult a professional plumber.
Installation instructions.
GEAppliances.com
Unpacking and Inspection
Be sure to check the entire softener for any shipping damage or parts loss. Also note damage to the shipping cartons. Contact the transportation company for all damage and loss claims. The manufacturer is not responsible for damages in transit.
Small parts needed to install the softener are packaged either in a bag or on a cardboard sheet. To avoid loss of the small parts, keep them packaged until you are ready to use them. Be sure not to discard components hidden in packaging.
Before you begin installation, read these
Installation Instructions completely. Then, obtain all the materials and tools you will need to make the installation. Failure to properly install the softener voids the warranty.
Check local codes. The installation must
conform to them.
In the Commonwealth of Massachusetts,
Plumbing Code 248 CMR shall be adhered to. Consult with your licensed plumber.
Use only lead-free solder and flux for all
sweat-solder connections, as required by state and federal codes.
Connect the softener to the main water
supply pipe before or ahead of the water heater. DO NOT RUN HOT WATER THROUGH THE SOFTENER. Temperature of water passing through the softener must be less than 120°F.
Use care when handling the softener.
Do not turn upside down, drop, drag or set on sharp protrusions.
Maximum allowable inlet water pressure is
125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve if necessary. (Adding a pressure reducing valve may reduce the flow.)
The softener works on 24 volt-60 Hz
electrical power only. Be sure to use the included transformer. Be sure the electric outlet and transformer are in an inside location to protect from moisture.
See Where to Install the Softener section for
more details.
WARNING:Do not use with water
that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. The water should be tested periodically to verify that the system is performing satisfactorily.
Small parts remaining after the installation
could be a choke hazard. Discard safely.
Important Installation Recommendations
Read entire manual. Failure to follow all guidelines and rules could cause personal injury or property damage.
4
Installation instructions.
Plan How You Will Install the Softener
You must first decide how to run in and out pipes to the softener. Look at the house main water pipe at the point where you will connect the softener. Is the pipe soldered copper, glued plastic or threaded galvanized? What is the pipe size?
WARNING: Use only lead-free
solder and flux to prevent lead poisoning.
See Typical Installation Illustration, Fig. 1. Use this as a guide when planning your particular installation. Be sure to direct the incoming hard
water supply to the softener valve inlet fitting.
The valve is marked IN and OUT. See illustration on page 5 to help you prepare.
Where to Install the Softener
Place the softener as close as possible to a
sewer drain, or other acceptable drain point or standpipe.
It is recommended to keep outside faucets
on hard water to save soft water and salt.
Do not install the softener in a place where it could freeze. Freeze damage is not covered by
the warranty.
Do not install the softener where it would
block access to the water heater or access to the main water shutoff.
Put the softener in a place where water
damage is least likely to occur if a leak develops. The manufacturer will not repair or pay for water damage.
A 120 volt electric outlet is needed to plug
in the included transformer. The softener has a 10 foot power cable. If the outlet is remote (up to 100 feet), use 18 gauge wire to connect. Be sure the electric outlet and
transformer are in an inside location, to protect from wet weather. Be sure the outlet is
unswitched to prevent accidental shutoff.
If installing in an outside location, you must
take the steps necessary to assure the softener, installation plumbing, wiring, etc., are as well protected from the elements (sunlight, rain, wind, heat, cold), contamination, vandalism, etc., as when installed indoors.
Outdoor installation is not recommended and voids the warranty.
Keep the softener out of direct sunlight.
The sun’s heat may distort non-metallic parts and may damage the electronics.
In and out fittings included with the softener
are 3/4(nominal) copper sweat tubes. You should maintain the same, or larger, pipe size as the water supply pipe, up to the softener inlet and outlet.
Use the included bypass valve to install the
softener. The bypass valve allows you to turn off water to the softener for servicing, but still have water in the house pipes. The in and out fittings referred to above connect to the bypass valve with the included nuts and washers.
Use copper, brass or galvanized pipe and
fittings. Some codes may also allow CPVC plastic pipes.
If additional drain hose is needed for valve
and salt tank drains, it can be ordered from GE Parts at 800.626.2002.
If a rigid valve drain is needed to comply
with plumbing codes, you can buy the parts needed to connect a 1/2copper tubing or plastic pipe drain.
Clean nugget or pellet water softener salt is
needed to fill the brine tank, see Step 8 in the Step-by-Step Installation Instructions.
Tools and Materials Required for Installation
5
GEAppliances.com
Typical Installation Illustration
Soft water
Hard water to outside faucets
MAIN WATER PIPE
Hard water
NOTE: See Drain Hose Connections section.
24V transformer
120-volt outlet
Bypass valve
Hard water to outside faucets
Inlet valve
Outlet valve
3-Valve Bypass System
For soft water service:
• Open the inlet and outlet valves
• Close the bypass valve
For bypass hard water:
• Close the inlet and outlet valves
• Open the bypass valve
Salt hole cover
SALT
GOES HERE
Brinewell
INLET
Washer (2)
Copper tube, 3/4″ (2)
Installation nut (2)
Bypass Valve
• Pull out for soft water service
• Push in for bypass
NOTE: Fittings supplied are for 3/4copper plumbing. If you have 1plumbing, do not use the copper tubes and nuts included. Buy 1NPT female adapters and connect directly to the 1NPT male threads of the bypass valve.
Nut (2)
Copper tube, 3/4″ (2)
Washer (2)
Installation adapter (2) (see above)
NOTE: Fittings supplied are for 3/4copper plumbing. If you have 1plumbing, do not use the copper tubes and nuts included. Buy 1NPT female adapters and connect directly to the 1NPT male threads of the adapters.
INLET
Union (not supplied) (2)
Optional 3-Valve Bypass Installation Illustration
Adapters for this installation are not supplied with the softener. To order these adapters, call GE Parts 800.626.2000. (Ask for Part # WS60X10006.)
Fig. 1
CROSSOVER
Use if water supply flows from the left.
Include single or 3-valve bypass.
Hard water
From softener outlet
Soft water
To softener inlet
Fig. 2
CROSSOVER
Use if water supply flows from the left.
Include single or 3-valve bypass.
Hard water
From softener outlet
Soft water
To softener inlet
MAIN WATER PIPE
Hard water
Soft water
120-volt outlet
24V transformer
Brinewell
SALT
GOES HERE
Salt hole cover
Drain
Drain
6
Fig. 3A
Fig. 3B
Fig. 3C
IN
OUT
Turn bypass valve upside down to connect to floor level plumbing
Valve body inlet or outlet
Bypass valve
(push all the way in)
Clip
END VIEW
Clip
Outlet
Inlet
O-ring seal goes into the outer groove only.
The clip snaps into the inner groove (see below).
Bypass valve
SIDE VIEW
Step-by-step installation instructions.
Turn off the gas or electric supply to the water heater, in the possibility
that the water heater may be drained while draining pipes.
Turn off the water supply to pipes to be cut and drain the house
water pipes.
Open both hot and cold faucets at the lowest location possible.
Release 2 clips at rear of cover. Rotate cover forward and lift up.
NOTE: For easier installation, remove the top cover.
1. INSTALL BYPASS VALVE
Remove plastic shipping plug and wire from valve outlet.
Push the bypass valve (lubricate o-ring seals with silicone grease)
into both ports of the valve as shown in Fig. 3A.
Snap the 2 large plastic clips in place, from the top, down as shown
in Figures 3A and 3B. Be sure they snap into place. Pull on the
bypass valve to make sure it is held securely in place.
2. MOVE THE SOFTENER ASSEMBLY INTO INSTALLATION POSITION
Be sure the installation surface is level and smooth. Sharp objects under the tank may puncture it. If needed, place the tank on a section of 3/4thick (minimum) plywood. Then, place shims under the plywood as needed to level the softener.
3. PLUMB “IN” AND “OUT” PIPES TO AND FROM SOFTENER
CAUTION: Observe all of the following cautions as you
connect inlet and outlet plumbing. See illustrations on page 5.
BE SURE INCOMING HARD WATER SUPPLY IS DIRECTED TO THE
SOFTENER VALVE INLET PORT. If house water flow is from the left, use a plumbing crossover as shown in Fig. 1, page 5. If the house water flows up from the floor level, turn the bypass valve upside down as shown in Fig. 3C.
If making a soldered copper installation, do all sweat soldering before
connecting pipes to the bypass valve. Torch heat will damage plastic
parts.
When turning threaded pipe fittings onto plastic fittings, use care not
to cross-thread.
Use pipe joint compound on all external pipe threads.
Support inlet and outlet plumbing in some manner (use pipe hangers)
to keep the weight off of the valve fittings.
NOTE: Be sure the turbine and support are firmly in place in the valve outlet. Blow into the valve port and observe the turbine for free rotation.
Turbine
Valve outlet
Turbine shaft and support
Drain Fitting
7
GEAppliances.com
Fig. 4A
Fig. 5
To sewer drain
Overflow drain hose
Hose clamp
Grommet
Clip
1/4NPT threads
Barbs
1/2O.D. copper tube (not furnished)
Cut barbs from drain fitting
Compression fitting, 1/4NPT X 1/2O.D. tube (not furnished)
Do not connect to valve drain hose.
Hose adapter
Fig. 4
Drain fitting on valve
Valve drain hose
FLOOR DRAIN
Tie or wire hose in place
11⁄2air gap
LAUNDRY TUB
SUMP
Clamp
STANDPIPE
Blue indicator light
4. CONNECT AND RUN THE VALVE DRAIN HOSE
Use the provided drain hose (20′ length included) to attach to the
valve drain fitting. To keep water pressure from blowing the hose off, use a hose clamp to secure in place. Cut the necessary length and use the remainder in Step 5.
Locate the other end of the hose at a suitable drain point (floor drain,
sump, laundry tub, etc.) that terminates at the sewer. Check and comply
with local codes.
IMPORTANT: If more drain hose is needed, it should be ordered from GE Parts at 800.626.2002. The water softener will not work if water
cannot exit this hose during recharge.
Tie or wire the hose in place at the drain point. High water pressure will
cause it to whip during the back-wash and fast rinse cycles of recharge.
Also provide an air gap of at least 11⁄2between the end of the hose and the drain point. An air gap prevents possible siphoning of sewer water
into the softener, if the sewer should “back-up.”
Elevating the drain hose may cause back pressure that could reduce
the brine draw during recharge. If raising the drain line overhead is required to get to the drain point, measure the inlet water pressure to the softener first. For inlet pressures between 20 and 50 psi, do not raise higher than 8above the floor. For inlet pressure above 50 psi, the drain line may be raised to a maximum height of 14′.
4A. CONNECTING A RIGID VALVE DRAIN TUBE
To adapt a copper drain tube to the softener, use a hacksaw to cut the barbed end from the drain fitting as shown in Fig. 4A. Rotate the drain fitting so the cutting blade clears the valve housing to prevent damage to valve. Buy a compression fitting (1/4female pipe thread x 1/2O.D. tube) and needed tubing from your local hardware store.
5. INSTALL THE BRINE TANK OVERFLOW FITTINGS AND HOSE
Insert the rubber grommet into the 3/4″ diameter hole in the brine
tank sidewall as shown in Fig. 5.
Push the end of the hose adapter elbow into the grommet as shown
in Fig. 5.
Attach a length of hose (use remaining hose from Step 4) to the hose
adapter elbow. Use a hose clamp to hold it in place.
Locate the other end of the hose at the drain point. DO NOT ELEVATE
this hose higher than the elbow on the brine tank.
IMPORTANT: DO NOT TEE OVERFLOW HOSE TO VALVE DRAIN HOSE.
NOTE: This drain is for safety only. If the cabinet (brine tank) should
over-fill with water, the excess is carried to the drain.
8
Step-by-step installation instructions.
6. INSTALL GROUNDING CLAMP
DANGER: Failure to properly attach ground
clamp could result in electrical shock.
If plumbing is metal, to maintain electrical ground continuity in the house cold water piping, install the included ground clamps as shown in Fig. 6.
Clean pipe with emery paper in the area where the
clamp is to be installed.
Install grounding clamps as shown, making sure
ground clamps fit freely around pipe.
Make sure lock washer is in place.
Handtighten screw, then one more full turn with
screwdriver.
NOTE: When replacing an existing softener, also replace grounding clamps.
If removing softener completely, hard-plumb the water line with same type of pipes as the original to assure plumbing integrity and ground continuity over the life of the home.
7. FLUSH PIPES, EXPEL AIR FROM SOFTENER AND TEST YOUR INSTALLATION FOR WATER LEAKS
CAUTION: To avoid water or air pressure
damage to softener inner parts, be sure to do the following steps in exact order.
Fully open 2 cold soft water faucets nearby the softener.
Place bypass valve in “bypass” position by pushing the
stem inward.
Fully open the house main water pipe shutoff valve.
Observe a steady flow from both faucets opened in the step above.
Place bypass valve in the “service” position EXACTLY
as follows. KEEP SOFT WATER FAUCETS OPEN.
SLOWLY pull or slide the valve stem (out) toward the
service position, pausing several times to allow the softener to pressurize slowly.
After about 3 minutes, open a HOT water faucet
for 1 minute, or until all air is expelled, then close. NOTE: If water appears cloudy or has salty taste,
allow to run for several more minutes, or until clear.
Close all water faucets.
Check your plumbing work for leaks and fix right
away if any are found. Be sure to observe previous caution notes.
Turn on the gas or electric supply to the water heater.
Light the pilot, if applicable.
8. ADD WATER AND SALT TO THE BRINE TANK
Lift the salt hole cover. Add about 3 gallons of water
into the tank. Do not add into the brinewell.
Fill tank with NUGGET, PELLET or coarse SOLAR
water softener salt with a purity of 99.5% or higher. Do not use rock, block, granulated and ice cream­making salts, or salt with iron-removing additives (except for Diamond Crystal®Red•Out®brand salt). Maximum salt storage capacity is approximately 200 lbs. Keep the salt hole cover closed unless servicing the unit or refilling with salt.
NOTE: If the softener is installed in a humid basement or other damp area, it is better to fill the tank with less salt, more frequently. Eighty to 100 lbs. of salt will last for several months, depending on water hardness, family size and water softening system model.
9. CONNECT TO ELECTRICAL POWER
To gain access to the transformer/power cord assembly, remove the salt hole cover from the softener. Unclip the tabs on the rear of the top cover and rotate the cover upwards to remove. DO NOT PULL OR DISCONNECT WIRING.
The softener works on 24 volt-60Hz electric power. The
included transformer changes standard 120-volt AC house power to 24 volts. Plug the transformer into a 120-volt outlet only. Be sure the outlet is always live so it can not be switched off by mistake.
Replace the top cover.
Replace the salt hole cover.
Fig. 6
Ground clamp
From valve outlet
To valve inlet
9
GEAppliances.com
Programming the Control
CONTROL SETTINGS REQUIRED upon installation and after an extended power outage.
NOTES:
WHEN THE TRANSFORMER IS PLUGGED INTO
THE ELECTRICAL OUTLET, 12:00 PM (flashing), and an arrow is displayed next to PRESENT TIME on the faceplate decal. The blue indicator light will also flash. Program the control as instructed below.
If - - - is flashing, use the UP button to set
the correct F or H code as follows: F35 for GXSF35E or F39 for GXSF39E. If you pass by the correct code number, use the DOWN button. Then press the MODE button to accept the correct model.
A “beep” sounds while pressing buttons for control
programming. One beep signals a change in the control display. Repeated beeps mean the control will not accept a change from the button you have pressed, and you should select another button.
To program the control, you will use the UP ,
DOWN and MODE buttons.
Use the MODE button to scroll arrow to desired
control function.
SET PRESENT TIME OF DAY
1. Press the MODE button until arrow points to PRESENT TIME.
2. Press UP or DOWN button to set. The UP button
advances the time; the DOWN button moves the time in reverse.
2. If the present time is between noon and midnight,
be sure PM shows in the display. If the present time is between midnight and noon, be sure AM shows in the display.
NOTE: Each press of an UP or DOWN button changes the time by one minute. Holding the button changes the time at a rapid rate.
3. When the present time is correct, press MODE to accept.
SET WATER HARDNESS NUMBER
1. Press the MODE button until arrow points to HARDNESS.
2. Press UP or DOWN button
to set your water hardness number in the display. DOWN decreases the hardness value. UP increases the hardness value.
NOTE: Each press of a button changes the display by 1, between 1 and 25. Above 25, the display changes 5 at a time (25, 30, 35, etc.). Holding a button in changes the numbers at a rapid rate.
3. When the display shows your water hardness (in grains per gallon), press MODE to accept.
NOTE: If there is clear water iron in your water supply, you will need to increase the hardness setting by 5 for each 1 ppm of clear water iron in your water supply.
You can get the grains per gallon (gpg) hardness of your water supply from a water analysis laboratory. If you are on a municipal supply, call your local water department. Or call Legend Technical Services, an independent laboratory, to request a water hardness test kit at
1.800.826.8553, extension 47. If your report shows
hardness in parts per million (ppm) or milligrams per liter (mg/l), simply divide by 17.1 to get the equivalent number of grains per gallon.
SET RECHARGE (STARTING) TIME
1. Press the MODE button until arrow points to RECHARGE TIME.
NOTE: A flashing 2:00 AM (factory default) should show in
the display. This is a good time for recharge to start (takes about 2 hours) in most households because water is not in use. HARD WATER is bypassed to house faucets during recharge.
If no change is needed, go to step 3. To change the recharge starting time, follow step 2.
2. Press UP or DOWN button to set the desired recharge start time. Be sure to observe the AM or PM as you did when setting the time of day.
NOTE: Each press of a button changes the time by 1 hour. Holding the buttons in changes the time at a rapid rate.
3. Press the MODE button to accept.
SALT
LEVEL
PM
SALT
LEVEL
AM
SALT
LEVEL
10
Step-by-step installation instructions.
Programming the Control (cont.)
SET SALT LEVEL
1. Press the MODE button until arrow points to SALT LEVEL.
2. Determine level of salt in brine tank using yellow
indicator on side of brine well, inside brine tank (see illustration on page 5).
3. Press UP or DOWN button to set the SALT LEVEL to correspond to level on yellow indicator in brine tank.
NOTE: Each press of a button changes the level by increments of 0.5 up to 8.0. As the number increases, the salt level bars increase on each whole number. Lowering the salt level below zero turns the SALT LEVEL indicator OFF.
4. Press the MODE button to accept. The display shows the present time of day and DAYS TO EMPTY. RECHARGE
TONIGHT may appear if unit is new.
DAYS TO EMPTY
The words DAYS TO EMPTY and a number are shown in the lower half of the display. This information is shown in the normal run display. This is to inform the user of the number of days before the salt level in the brine tank reaches Level 0. There will be salt left in the salt tank, but it may not be sufficient to fully recharge the system. Salt should be added at this time to avoid hard water. The value is updated daily and whenever the SALT LEVEL value is changed.
NOTE: For the first several weeks of operation, the DAYS TO EMPTY may provide erratic operation. For example, the
blue indicator light may flash, showing that more salt is required, when the actual salt level in the tank is well above the Level 0. In some cases, the DAYS TO EMPTY may even increase over a several week period.
It takes a couple of months for the water softener to learn your water usage pattern. Once it does this, it will accurately determine actual salt usage pattern. During this period, check salt level when blue indicator light flashes. If the salt level in the tank is at Level 1 or above, allow system to run. Be sure to reset your salt level indicator each time you add salt to the system.
SALT
LEVEL
SALT
LEVEL
SALT
LEVEL
PM
DAYS TO EMPTY
RECHARGE TONIGHT
SALT
LEVEL
PM
DAYS TO EMPTY
E
GEAppliances.com
11
Optional Control Settings
The controller display has several options and features.
LOW SALT ALARM
The LOW SALT ALARM, when enabled, will sound the beeper when the DAYS TO EMPTY value is 15 days or less. To change this setting, press and hold the MODE button for 3 seconds. ON (factory default) or OFF will flash in the display. Press the UP or DOWN buttons to toggle this feature ON or OFF. Press the MODE button to accept, and the display will move to SALT EFFICIENCY.
SALT EFFICIENCY
When the SALT EFFICIENCY feature is ON, the unit will operate at a salt efficiency of at least 4000 grains of hardness removed per pound of salt. This mode of operation is the most efficient setting for salt usage, because the system will tend to recharge more often, with less salt usage. Turning the feature OFF will tend to lengthen the time between recharge cycles, which will provide the most efficient usage of water, but may use more salt. The degree of difference between these two cycles is highly dependent on the water usage and hardness at a particular installation.
If you have very hard water, and you find your system is regenerating every 1-2 days, turn the SALT EFFICIENCY to OFF to lengthen the time between regenerations.
NOTE: California Regulations require this feature to be ON for installations in California.
To change the setting, press the UP or DOWN buttons to toggle the feature ON or OFF. Press the
MODE button to accept. The display will move to SYSTEM/ELECTRONIC DIAGNOSTICS.
SYSTEM/ELECTRONIC DIAGNOSTICS
This display contains system diagnostics information to assist in troubleshooting problems with the system. See pages 15–18 for details. Press the MODE button to return to the normal run display.
LOST TIME SIGNAL
If time is lost on the display due to power interruption, the blue indicator light will flash 4 times every second, until the present time of day is entered.
LOW SALT SIGNAL
When the DAYS TO EMPTY drops to 15, the blue indicator light and DAYS TO EMPTY in the display will flash every second and the alarm will beep every 30 seconds (from 8:00 AM to 8:00 PM), to notify the user that the unit is running low on salt. As soon as any button is pressed, the alarm will stop beeping. The blue indicator light and DAYS TO EMPTY will continue to flash. Once salt is added to the brine tank and the SALT LEVEL is reset, the DAYS TO
EMPTY will be reset.
ERROR SIGNALS
If there is an error code detected, the blue indicator light will flash 4 times every second, the display will flash Err and the alarm will beep every 30 seconds (from 8:00 AM to 8:00 PM), to signal that the softener requires service. The alarm can be turned off by pressing any button, but the blue indicator light and display will continue to flash.
See page 16 for information to assist in troubleshooting error codes. Once the problem is corrected, disconnect the transformer from the wall outlet momentarily, and plug it back in. The normal display will appear. The motor may run for several minutes, as the unit resets. If the problem is not corrected, the error code will reappear in 6 minutes.
BLUE INDICATOR LIGHT
Steady blue light indicates that the unit is working correctly. The light flashes when the unit needs attention from the user.
Light flashes and DAYS TO EMPTY flashes—check salt level
and add salt as required.
Light flashes and Err is in the display—electrical problem
with system—see page 16.
Light will also flash when power to the unit has been interrupted. Check the PRESENT TIME setting.
SALT
LEVEL
SALT
LEVEL
E
SALT
LEVEL
SALT
LEVEL
These systems conform to NSF/ANSI 44 for the specific capacity claims as verified and substantiated by test data. * Testing was performed using pellet grade sodium chloride as the regenerant salt. ** Efficiency rating is valid only at the lowest stated salt dosage. These softeners were efficiency rated according to
NSF/ANSI 44.
*** Extent of iron removal may vary with conditions. The capacity to reduce clear water iron is substantiated by
WQA test data. State of Wisconsin requires additional treatment if water supply contains greater than 5 ppm clear water iron. Use of Diamond Crystal
®
Red•Out®or Super Iron Out®will improve iron removal. Refer to
Cleaning Iron Out of the Water Softening System section.
**** Canada working pressure limits: 1.4–7.0 kg/cm
2
.
33⁄8
OUTLET
INLET
INLET–OUTLET
471⁄2
41
1
4
16
Step-by-step installation instructions.
Sanitizing Procedures
To complete the installation, do the following sanitizing procedures.
Care is taken at the factory to keep your water softener clean and sanitary. Materials used to make the softener will not infect or contaminate your water supply and will not cause bacteria to form or grow. However, during shipping, storage, installing and operating, bacteria could get into the softener. For this reason, sanitizing as follows is suggested when installing.
NOTE: Sanitizing is recommended by the Water Quality Association for disinfecting.
1. Be sure to complete all installation steps,
including programming the control.
2. Pour about 3/4 oz. (11⁄2 tablespoons) of
common 5.25% unscented household bleach (Clorox, Linco, Bo Peep, White Sail, Eagle, etc.) into the brinewell. Refer to illustration on page 5.
3. IMPORTANT: Press and hold for 3 seconds the faceplate RECHARGE button to start an immediate recharge. RECHARGE begins to flash in the display. The bleach will be drawn through the water softener and out the drain. This process takes approximately 2 hours.
4. If, after sanitization, water from the house
faucet tastes salty or has a slight color, this is a preservative from the resin tank. Turn on the cold soft water faucets and drain for a few minutes or until clear.
NOTE: When the sanitizing recharge is over, all remaining bleach is flushed from the conditioner and your house COLD water supply is fully soft immediately. However, your water heater is filled with hard water and as hot water is used, it will refill with soft water. When all the hard water is replaced in the water heater, hot only and mixed hot and cold water will be fully soft. If you want totally soft water immediately, after the above recharge, drain the water heater until the water runs cold.
WARNING:If you do drain the
water heater, use extreme care as the hot water could cause burns. Turn the water heater off prior to draining.
Specifications/Dimensions
19
GXSF35E GXSF39E
Rated Capacity* 14,000 grains with 15,300 grains with
2.8 lbs. of salt 3.0 lbs. of salt
29,600 grains with 32,800 grains with
8.8 lbs. of salt 9.6 lbs. of salt
35,200 grains with 39,100 grains with
14.7 lbs. of salt 16.1 lbs. of salt
Rated Efficiency** 5,000 grains/lb. 5,100 grains/lb.
@ 2.8 lbs. of salt @ 3.0 lbs. of salt
Amount of High Capacity Resin (lbs/cu. ft) 47.8/0.92 52.5/1.01
Resin Tank Nominal Size (in., dia. x height) 9 x 40 9 x 40
Service Flow Rate (gpm) 8.5 8.0
Water Supply Maximum Hardness (gpg) 100 110
Water Supply Maximum Clear Water Iron (ppm)*** 6 8
Water Pressure Limits (min.–max. psi)**** 20–125 20–125
Pressure Drop at Rated Service Flow (psig) 15 15
Water Temperature Limits (min.–max. °F) 40–120 40–120
Maximum Flow Rate to Drain (gpm) 2.0 2.0
12
13
About the water softener system.
GEAppliances.com

Service

When the water softening system is providing soft water, it is called “Service.” During service, hard water flows from the house main water pipe into the water softening system. Inside the water softening system resin tank is a bed made up of thousands of tiny, plastic resin beads. As hard water passes through the bed, each bead attracts and holds the hard minerals. This is called ion-exchanging. It is much like a magnet attracting and holding metals. Water without hard minerals (soft water) flows from the water softening system and to the house pipes.
After a period of time, the resin beads become coated with hard minerals and they have to be cleaned. This cleaning is called recharge. Recharge is started at 2:00 AM (factory setting) by the water softening system control, and consists of five stages or cycles. These are
FILL, BRINING, BRINE RINSE, BACKWASH and FAST RINSE.
For emergency needs, hard water is available to the home during the recharge cycles.
However, you should avoid using HOT water because the water heater will fill with the hard water.
Automatic Hard Water Bypass During Recharge
Fill
Salt dissolved in water is called brine. Brine is needed to clean the hard minerals from resin beads. To make the brine, water flows into the salt storage area during the fill stage.
Brining
During brining, brine travels from the salt storage area into the resin tank. Brine is the cleaning agent needed to remove hard minerals from the resin beads. The hard minerals and brine are discharged to the drain.
The nozzle and venturi create a suction to move the brine, maintaining a very slow rate to get the best resin cleaning with the least salt.
Brine Rinse
After a pre-measured amount of brine is used, the brine valve closes. Water continues to flow in the same path as during brining, except for the discontinued brine flow. Hard minerals and brine flush from the resin tank to the drain.
Backwash
During backwash, water travels up through the resin tank at a fast flow rate, flushing accumulated iron, dirt and sediments from the resin bed and to the drain.
Fast Rinse
Backwash is followed by a fast flow of water down through the resin tank. The fast flow flushes brine from the bottom of the tank, and packs the resin bed.
After fast rinse, the water softening system returns to soft water service.
14
About the water softener system.

Breaking a Salt Bridge

Sometimes, a hard crust or salt bridge forms in the salt storage area. It is usually caused by high humidity or the wrong kind of salt. When the salt bridges, an empty space forms between the water and salt. Then salt will not dissolve in the water to make brine.
If the brine tank is full of salt, it is hard to tell if you have a salt bridge. Salt is loose on top, but the bridge is under it. The following is the best way to check for a salt bridge.
Salt should be loose all the way to the bottom of the tank. Take a broom handle or like tool, and carefully push it down into the salt, working it up and down. If the tool strikes a hard object (be sure it’s not the bottom or sides of the tank), it’s most likely a salt bridge. Carefully break the bridge with the tool. Do not pound on the walls of the tank.
If the wrong kind of salt made the bridge, take it out. Then fill the tank with nugget or pellet salt only. In humid areas, it is best to fill with less salt, more often to prevent a salt bridge from forming.
A clean nozzle and venturi is needed for the water softening system to work properly. This
small unit makes the suction to move brine from the salt storage area to the resin tank during recharge. If it becomes plugged with sand, dirt, etc., the water softening system will not work and you will get hard water.
To get to the nozzle and venturi, remove the water softening system top cover. Be sure the water softening system is in service cycle (no water pressure at nozzle and venturi). Then, while holding the nozzle and venturi housing with one hand, remove the cap. Lift out the screen support and screen, then the nozzle and venturi. Wash and rinse the parts in warm water until clean. If needed, use a small brush to remove iron or dirt. Also check and clean the gasket.
NOTE: Some models have a small flow plug located in the nozzle and venturi, and/or a small cone shaped screen in the housing. Be sure to check and clean these parts, if your model is so equipped.
Carefully replace all parts in the correct order. Lightly lubricate the o-ring seal with clean silicone grease or petroleum jelly and place in position. Install and tighten the cap, by hand only.
Do not overtighten the cap.

Cleaning the Nozzle and Venturi Assembly

Push tool into salt bridge to break
Pencil mark
Broom handle
Salt
Salt bridge
Water level
1–2
IMPORTANT: Be sure small holes in the gasket are centered directly over the small holes in the nozzle and venturi housing.
*Install with numbered side up, concave side down.
Cap
O-ring seal
Screen support
Screen
Screen
Nozzle & Venturi
Nozzle & Venturi housing
Gasket
*Flow plug
*Flow plug
15
GEAppliances.com
During normal operation, the present time of day and AM or PM and DAYS TO EMPTY show in the control display area. When the demand computer determines a recharge is needed, RECHARGE TONIGHT begins to flash in the display along with the present time. RECHARGE TONIGHT flashes until the next recharge start time; then changes to RECHARGE, which flashes until the recharge is over.
Normal Operation, Control Displays
Sometimes, a manually started recharge may be desired or needed. Two examples:
You have used more water than usual
(house guests, extra washing, etc.) and you may run out of soft water before the next recharge.
The system ran out of salt.
Use one of the following features to start a recharge immediately, or at the next preset recharge start time.
RECHARGE TONIGHT
Touch (do not hold) the RECHARGE button. RECHARGE TONIGHT flashes in the control
display area. A recharge will occur at the next preset recharge start time. If you decide to cancel this recharge, touch the same button once more.
RECHARGE
Press and hold the RECHARGE button until RECHARGE starts to flash in the control display
area. The water softening system begins an immediate recharge and, when over in about two hours, you will have a new supply of soft water. Once started, you cannot cancel this recharge.
Feature: Optional Recharge Controls
Feature: Memory
If electrical power to the water softening system is interrupted, the control display is blank, and the blue indicator light is off, but the control keeps correct time for about 6 hours. When power is restored, you have to reset the present time only if the display and blue indicator light are flashing. All other settings are maintained and never require resetting unless a change is desired.
If the time is flashing after a long power outage, the water softening system continues to work as it should to provide you with soft water. However, recharge may occur at the wrong time of day until you reset the control to the correct time of day.
The control computer has a self-diagnostic function for the electrical system (except input power and water meter). The computer monitors the electronic components and circuits for correct operation. If a malfunction occurs, an error code appears in the control display.
The chart on Error Codes shows the error codes that could appear and possible reasons for each code. See Manually Initiated Electronic Diagnostics to further isolate the defect.
Feature/Service: Automatic Electronic Diagnostics
16
To remove an error code: 1. Unplug transformer.
2. Correct defect.
3. Plug transformer in.
4. Wait for at least 6 minutes. The error code will return if the reason for
the error code was not corrected.
NO SOFT
WATER
CONTROL SHOWS WRONG TIME AND DAY, AND/OR IS FLASHING.
CONTROL DISPLAY BLANK.
CONTROL DISPLAY SHOWS CORRECT TIME AND DAY AND IS STEADY.
Check electrical power to control (outlet, transformer, power cable, all connections).
Do manual diagnostics.
NO POWER
POWER OK
REPAIR AS NEEDED
CONTROL DEFECTIVE
Do manual diagnostics to verify proper function.
Electrical power was off. Reset the correct time of day.
Investigate reason for power loss.
About the water softener system.
Service: Electronic Demand Time Features and Service
If you are not getting soft water, and an error code is not displayed, use the procedures below to find the problem. First make the following visual checks.
VISUAL CHECKS:
1. Is there electrical power to the outlet the
water softening system transformer is plugged into?
2. Is there sufficient salt in the storage tank?
3. Is the softener bypass valve directing water
for soft water service?
4. Is the valve drain hose open to the drain,
not more than 8above the softener, and unobstructed? If hose is above 8, see page 7, section 4.
If you do not find a problem with the visual checks, continue below.
Service: Timer/Softener, Service Checkout Procedure
ERROR CODE DISPLAYED ERR 01 ERR 02 ERR 03 ERR 04 ERR 05
POSSIBLE DEFECT • Motor • Position • Motor • Position • Control
inoperative switch inoperative switch or
or wiring wiring harness harness
• Wiring • Control • Control • Control harness or connection to switch
• Position switch
• Control
17
GEAppliances.com
1. To enter diagnostics, press and hold
the MODE button for 3 seconds until the LOW SALT ALARM screen shows.
2. Press the MODE button 2 times to advance through LOW SALT ALARM and SALT EFFICIENCY options. See Programming the Control for details on these two options.
3. OPERATION OF DIAGNOSTICS
Valve Position—Press the RECHARGE button to
initiate a recharge cycle. Press again to manually index valve to next position. See Service: Manually Advance Recharge Check for details.
0 – Service 1 – Fill 2 – Brine 3 – Backwash 4 – Fast Rinse
Motor Operation—Two dashes will circulate around
when motor should be running.
Position Switch Operation—
– Closed—valve rotating to next position
– Open—valve in position, service, fill, brine, etc.
Water Meter—Indicates whether water is flowing
through valve.
– 000 indicates no water is flowing through the valve
– Open nearby soft water faucet
– 000 to 199 (continual) shows water is flowing. Display
repeats for each gallon of water passing through the meter. Control will beep at every gallon.
– If there is no reading in the display, with faucet
open, check the sensor. Pull the sensor from the valve outlet port, and pass a small magnet in front of the sensor. Counter should index in the display. If counter does not index, check to make sure harness is connected to board properly. If there is a reading in the display, there may be a problem associated with the turbine. Turn off water supply, close the by-pass valve, and disconnect by-pass valve from valve body. Check turbine for binding or restriction due to debris. If this does not correct the problem, the Timer, Sensor or Turbine may require replacement.
4. Historical data about the softener is available.
Press and hold the UP button to display the number
of days this control has had electrical power applied.
Press and hold the DOWN button to display the
number of recharges initiated by this control since the model code number was entered.
5. Press the MODE button to return to normal operation
and display.
Service: Set Model (F or H) Code
1. To change or check model code, first press and hold the MODE button for 3 seconds until the LOW SALT ALARM
screen shows.
2. Press and hold the MODE button again for 3 seconds. A display with at the top will appear.
3. Press the UP or DOWN buttons to select the correct model code.
SR22–GXSF27E, F31–GXSF31E, F35–GXSF35E, F39–GXSF39E, H39–GXSH39E, H45–GNSH45E
4. Press the MODE button one time to return to normal operation and display. If the model code was changed:
the display will go blank momentarily, then display the
model code entered.
the display will then return to the set present time
display, and the blue indicator light will flash. The control will have to be reprogrammed. See Programming the Control.
NOTE: If the control is left in any of the above diagnostic displays, or a flashing display when setting time, hardness, etc., it will revert back to the normal display in 4 minutes.
Service: Manually Initiated Electronics Diagnostics
Water meter
Valve position
Position switch
Motor
Motor
Turbine
Turbine support and shaft
Sensor housing
Position switch
Valve outlet
SALT
LEVEL
SALT
LEVEL
SALT
LEVEL
SALT
LEVEL
18
About the water softener system.
NOTE: The control display must show a steady
time (not flashing).
1. Press the RECHARGE button and hold in for three seconds. RECHARGE begins to flash as the water softening system enters the fill cycle of recharge. Remove the brinewell cover and, using a flashlight, observe fill water entering the brine tank. If water does not enter the tank, look for an obstructed nozzle, venturi, fill flow plug or brine tubing. See Care and Cleaning of the Water Softener System section.
2. After observing fill, press the RECHARGE button to move the water softening system into brining. A slow flow of water to the drain will begin. Verify brine draw from the brine tank by shining a flashlight into the brinewell and observing a noticeable drop in the liquid level over an extended period of time.
NOTE: Be sure a salt bridge is not preventing water from contacting salt. See Care and
cleaning of the water softening system section.
If the water softening system does not draw brine, check:
nozzle and/or venturi dirty or defective.
defective nozzle and venturi seal.
nozzle and venturi not seated properly
on gasket.
other inner valve defect (rotor seal, rotor
and disc, wave washer, etc.).
restricted drain (check drain fitting and
hose).
NOTE: If water system pressure is low, an elevated drain hose may cause back pressure, stopping brine draw.
3. Again, press the RECHARGE button to move
the water softening system into backwash. Look for a fast flow of water from the drain hose. A slow flow indicates a plugged top distributor, backwash flow plug or drain hose.
4. Press the RECHARGE button to move the
water softening system into fast rinse. Again look for a fast drain flow. Allow the water softening system to rinse for a few minutes to flush out any brine that may remain in the resin tank from the brining cycle test.
5. To return the water softening system to service, press the RECHARGE button.
Service: Manually Advance Recharge Check
19
Care and cleaning of the water softening system.
GEAppliances.com
Brine (salt dissolved in water) is needed for each and every recharge. The water for making brine is metered into the salt storage area by the water softening system valve and control.
However, you must keep the tank supplied with salt.
When to refill with salt: If the blue indicator
light and DAYS TO EMPTY are flashing, there is less than 15 days supply of salt. Refill with salt. In humid areas it is best to refill with less salt and more often, to avoid the forming of a salt bridge (see page 14). After adding salt, remember to reset the SALT LEVEL in the control (see page 10). Never allow the salt level to drop below zero on the yellow indicator before you refill it. Without enough salt, you will soon have hard water.
Use clean water softening salts only, at least
99.5% pure. NUGGET, PELLET or coarse
SOLAR salts are recommended. Do not use rock,
block, granulated or ice cream making salts.
They contain dirt and sediments, or mush and cake, and will create maintenance problems.
CAUTION:
Water softening salt with
iron removing additives: Some salts may have
an additive to help the water softening system handle iron in the water supply. Although this additive may help to keep the water softening system resin clean, it may also release corrosive fumes that weaken and shorten the life of some water softening system parts. GE recommends using only Diamond Crystal
®
Red•Out®brand salt.
Checking the Salt Storage Level and Refilling
Your water softening system takes hardness minerals (calcium and magnesium) out of the water. Also, it can control some (see the Specification Guidelines section) “clear water” iron. With clear water iron, water from a faucet is clear when first put into a glass. After 15 to 30 minutes, the water begins to cloud or turn rust colored. A water softening system will not remove any iron that makes the water cloudy or rusty as it comes from the faucet (called red water iron). To take red water iron out of water, or over the maximum of clear water iron, an iron filter or other equipment is needed.
GE recommends using only Diamond Crystal
®
Red•Out®brand salts with Iron Fighter
®
additive to help keep the resin bed clean of clear iron. If your water supply has clear water iron, periodic resin bed cleaning is needed. GE recommends using Super Iron Out®brand resin bed cleaner to thoroughly clean your resin bed if your iron content is high. Clean the bed at least every six months, or more often if iron appears in the soft water between cleanings.
IMPORTANT: It is important to mix the resin bed cleaner with water (following the manufacturer’s instructions), pour it into the brinewell tube (see page 5) and recharge the softener immediately. Do not pour the resin bed cleaner in with the salt, as it will not be as effective in cleaning the resin, and can cause damage to the softener if it is left in the brine tank for an extended period due to the corrosive gases that are formed.
Cleaning Iron Out of the Water Softening System
20
Troubleshooting Tips Save time and money! Review the chart on following pages first
and you may not need to call for service.
Problem Possible Causes What To Do
No soft water Faucet or fixture where sample was
To conserve salt, the installer
may have isolated some fixtures
taken not plumbed to soft water
(outside faucets, toilets, etc.)
from soft water. From the outlet
NOTE:
Be sure sample is from a faucet of the water softening system, trace the water flow path, that does not mix soft and hard water. in house plumbing. If soft water is not directed to a faucet For example, a single lever kitchen faucet, or
fixture where wanted, consult a plumber.
if the cold side is plumbed to hard water.
No salt in the brine tank or Check for a salt bridge or, if the
tank is empty, refill with
salt bridged recommended salt. Press (for 3 seconds) the RECHARGE
button to start an immediate recharge and restore soft water supply.
Transformer unplugged at wall outlet or
Check for a loss of electrical power to the water softening
power cable to softener not connected. system, due to any of these conditions and correct as needed. Fuse blown or circuit breaker popped With the power supply restored, observe the faceplate time on circuit to electrical outlet. display and read Programming the Control section. Electrical outlet on a circuit that can
NOTE: The electrical outlet for the softener should be continuously
be switched off
live
so it cannot be accidentally switched off.
Manual bypass valve in Be sure the bypass valve stem
is positioned properly, with the
bypass position
knob in the OUT position. Observe i
nstructions on the decal
at the end of the stem.
Valve drain hose pinched, plugged,
Any restriction in this drain hose
may prevent proper
elevated too high or otherwise
operation of the
nozzle and venturi and reduce or prevent
restricted brine draw during recharge.
Nozzle and venturi dirty, incorrectly Refer to Cleaning the Nozzle and Venturi Assembly
instructions.
assembled or damaged
With water pressure to the
water softening system off, take the nozzle assembly apart. Inspect, clean and replace as needed. Any foreign particle(s), scratches, nicks, etc., in the passages can
prevent operation. Be sure holes in the gasket are
centered over holes in the housing.
NO SOFT WATER—Most Common Problems:
Check the following before calling for service:
Not enough salt—should be at least 1/3 full.
Bypass valve in “Bypass” position—knob should be in the “OUT” (service) position.
Hardness setting too low—check hardness setting and adjust. Verify hardness of
supply water—from local water company, water test or call the GE Answer Center.
Salt Bridge—salt solidifies above water level so that brine water is not in contact
with salt. See the Breaking a Salt Bridge section.
Before you call for service…
Loading...
+ 44 hidden pages