GE GXRM10RBL User Manual [en, es, fr]

GEAppliances.com
Reverse Osmosis
215C1219P004 49-50237-2 11-09 GE
Filtration System
GXRM10RBL
Owner’s Manual
and Installation
Safety Instructions
Specification Guidelines . . . . . . . . . . . . .3
Installation Instructions
Before Beginning Installation . . . . . . . .4
Faucet Drain Tubing and
Water Supply Tubing . . . . . . . . . . . . . . . .9
Faucet Installation . . . . . . . . . . . . . . . . . .8
Filtration Drain Connection . . . . . . . . . .9
System Assembly . . . . . . . . . . . . . . . . . .10
Things to Check
Before Installation . . . . . . . . . . . . . . . . . .5
Tools and Materials Required . . . . . . . .4
Water Supply . . . . . . . . . . . . . . . . . . . . .6, 7
Care and Cleaning
Prefilter, Postfilter and
RO Cartridge Replacement . . . . .11, 12
Sanitization . . . . . . . . . . . . . . . . . . . . . . . .11
Water Test Kit . . . . . . . . . . . . . . . . . . . . .13
Operating Instructions
About the RO System . . . . . . . . . . .14, 15
Troubleshooting Tips . . . . . . . . . .16
Consumer Support
Consumer Support . . . . . . . .Back Cover
Parts List/Catalog . . . . . . . . . . . . . .17, 18
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . .20
Manuel d’utilisation
et d’installation
Manual del propietario
y instalación
La section française commence à la page 21
Osmose Inversée
Système de Filtration
La sección en español empieza en la página 41
Ósmosis Inversa
Sistema de Filtración
GXRM10RBL is Tested and Certified by NSF International against NSF/ANSI Standard 58 and 42 and CSA B483.1 for reduction of the claims specified on the Performance Data Sheet.
Write the model and serial numbers here:
Model # __________________
Serial # __________________
You can find them on the bracket.
C
U.S.
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
n Check with your state and local public works
department for plumbing and sanitation codes. You must follow these guidelines as you install the Reverse Osmosis system. Using a qualified installer is recommended.
n If house water pressure is over the maximum
(125 pounds per square inch), install a pressure reducing valve in the water supply line to the Reverse Osmosis system.
n
Be sure the water supply conforms with the Specification Guidelines. If the water supply conditions are unknown, contact your municipal water company or your local health department for a list of contaminants in your area and a list of laboratories certified by your state to analyze drinking water.
WARNING: Before using the Reverse
Osmosis system for the first time, the system must be purged. The Reverse Osmosis cartridge contains a food grade preservative that must be purged from the system. The preservative will give product water an unpleasant taste and odor.
n This product reduces fluoride in drinking water.
Please consult your dentist if you have questions.
WARNING: Do not use with water that is
microbiologically unsafe or of unknown quality
without adequate disinfection before the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not reduce other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section of the Performance Data Sheet for further information.
This Reverse Osmosis system contains a replaceable treatment membrane cartridge critical for effective reduction of Total Dissolved Solids. The water should be tested periodically to verify that the system is performing satisfactorily. See the About the Water Test Kit section. This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280kPa (40 psig) or greater.
SAVE THESE INSTRUCTIONS
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
n Install or store where it will not be exposed to
temperatures below freezing or exposed to any type of weather. Water freezing in the system will damage it. Do not attempt to treat water over 100°F.
n Do not install on HOT WATER. The temperature
of the water supply to the Reverse Osmosis system must be between the minimum of 40°F and the maximum of 100°F. See the Specification Guidelines.
n Extended non-use of the Reverse Osmosis system.
If the system has not been used for one week or more, open the RO water faucet and allow the system to drain. Close the RO water faucet and allow the system to regenerate the water supply.
n Recommended installation is under the sink. However,
the unit can be installed in a remote location, up to 20 feet away from the sink. Additional installation materials may be required. If Reverse Osmosis system is connected to a refrigerator icemaker, a special icemaker connection kit is required (RVKIT). Do not use copper tubing for the connection between the Reverse Osmosis system and the refrigerator.
WARNING: Discard all unused parts and
packaging material after installation. Small parts remaining after the installation could be a choke hazard.
n
Sanitize upon installation of the Reverse Osmosis system and after servicing inner parts, including replacement of prefilter, postfilter and Reverse Osmosis cartridge. It is important to have clean hands while handling inner parts of the system. See the Sanitization section.
n
This Reverse Osmosis system contains a replaceable component critical to the efficiency of the system. Replacement of the Reverse Osmosis component should be with one of identical specifications, as defined by the manufacturer, to assure the same efficiency and contaminant reduction performance. See Automatic Shutoff Valve section on page 13.
BE SURE TO FOLLOW ALL APPLICABLE STATE AND LOCAL CODES.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of property damage or personal injury.
SAFETY PRECAUTIONS
PROPER INSTALLATION AND MAINTENANCE
This Reverse Osmosis system must be properly installed and located in accordance with the Installation
Instructions before it is used.
Consumer Support
Troubleshooting Tips
Operating Instructions
Safety Instructions
Installation
Instructions
2
Consumer Support
Troubleshooting Tips
Operating InstructionsSafety Instructions
Installation
Instructions
Specification guidelines. GEAppliances.com
The system makes a good supply of drinking water each day.
How much it will make depends primarily on these things…
Product – height 15width 14depth 5.5
Incoming Water pH
WATER SOFTENER RECOMMENDED
INCOMING WATER HARDNESS (GPG)
60
50
40
30
2010
8
6
7
7.5
6.5
Water Softener
not required
Maximum iron, manganese, hydrogen sulfide (ppm) . . . . . . . . . . . . . . . . . . . .<0.1
Chlorine in water supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0 ppm maximum allowable
b
Feed water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–10
Product (quality) water, 24 hours—gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.83
a
Percent rejection of TDS (new membrane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95.1%
a
Cyst reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99.99%
Storage tank capacity—gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
d
Efficiency rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.63%
e
Recovery rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18.77%
f
Automatic shutoff control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .yes
Prefilter and postfilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FX12P) Carbon Block
Reverse Osmosis membrane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FX12M) Thin Film Polyamide
Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height 15” width 14” depth 5.5
Feed water pressure limits—pounds per square inch (psi) . . . . . . . . . . . . . . . . . . . . . .40–125
c
Feed water temperature limits—minimum/maximum degrees F . . . . . . . . . . . . . . .40–100
Maximum Total Dissolved Solids (TDS)—parts per million (ppm) . . . . . . . . . . . . . . . .2000
Maximum water hardness at 6.9 pH recommended to optimize membrane
life—grains per gallon (gpg) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
For water with hardness greater than 10 grains (at 6.9 pH), the use of a softener is recommended. Failure to install a water softener will reduce the life of the Reverse Osmosis membrane. See chart for additional information on the possible need for a water softener.
a. Tested according to NSF/ANSI Standard 58. Source water test parameters are 50 psig, 77°F,
pH of 7.5 ± 0.5 and 750 ± 40 ppm total dissolved solids.
b. Reduced by the Reverse Osmosis prefilter. REGULAR MAINTENANCE IS REQUIRED. Chlorine will destroy
the Reverse Osmosis membrane.
c. If house water pressure is over 125 psi, install a pressure reducing valve in the water supply line.
If house water pressure is under 40 psi, install a Reverse Osmosis booster pump (contact your local plumbing supply company).
d. Theoretical tank capacity. When tested according to NSF/ANSI Standard 58 at 50 psig inlet pressure,
tank capacity is 2.3 gallons.
e. Efficiency rating means the percentage of the influent water to the system that is available
to the user as Reverse Osmosis treated water under operating conditions that approximate typical daily usage.
f. Recovery rating means the percentage of influent water to the membrane portion of the system
that is available to the user as Reverse Osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
3
Installation
Reverse Osmosis Filtration System
Instructions
Model GXRM10RBL
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT — Save these instructions
for local inspector’s use.
IMPORTANT — Observe all governing
codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions
for future reference.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
A shut-off valve must be available or added near the installation point.
TOOLS AND MATERIALS REQUIRED FOR INSTALLATION
Drill with 1-1/2” Drill Bit (type as required) if mounting hole is needed for faucet
Adjustable Open-End Wrenches
Phillips and Flat-Blade Screwdrivers
Utility Knife
CONTENTS INCLUDED WITH PRODUCT
Reverse Osmosis Assembly and Tubing
Product Literature (Owner’s Manual and
Installation) and Performance Data Sheet
Water Supply Inlet Parts Bag
Drain Line Adapter
Storage Tank
Faucet
Pipe Thread Tape
4
5
Installation Instructions
Things to Check Before Beginning Installation
WATER SUPPLY
The water supply to the undercounter Reverse Osmosis system must have the qualities listed in the specifications (see the Specif ications Guidelines section). Municipal water supplies most often will have these qualities. Well water may need conditioning—have the water tested by a water analysis laboratory and get their recommendations for treatment.
CAUTION: For water with a hardness
greater than 10 grains (at 6.9 pH), the use of a softener is recommended. Failure to install a softener will reduce the life of the Reverse Osmosis membrane. See the Specifications Guidelines section for additional information on the possible need for a softener.
DRAIN POINT
A suitable drain point and air gap (check your local codes) are needed for reject water from the
Reverse Osmosis membrane cartridge.
BASEMENT INSTALLATION
If installing in a basement, leave enough tubing in place during installation to be able to move the unit to the floor for ease at servicing and making filter/membrane changes. Additional tubing and fittings required.
RO FAUCET
The RO product water faucet installs on the sink or on the countertop next to the sink. Often, it is installed in an existing sink spray attachment hole or a hole may be drilled. Space is required underneath for tubing to and from the faucet, and for securing the faucet in place. All faucet connections and installation procedures are done on or above the sink or countertop. Refer to illustration above.
Storage tank
Saddle valve
HOT
Drain adapter
3/8black drain tubing
RO product water faucet mounted through sink or countertop
Yellow (inlet)
Orange
1/4black
Blue (to faucet)
COLD
Installation Instructions
WATER SUPPLY
Check and comply with local plumbing codes as you plan, then install a cold water supply fitting. For new home
installation using standard plumbing fittings, see first two illustrations below. A typical installation for existing homes using the saddle valve is shown in the third illustration below.
B. OPTIONAL HOME INSTALLATION
(Where codes permit)
*For 1/4OD or larger metal tubing only. NOTE: Codes in the state of Massachusetts require
installation by a licensed plumber and do not permit the use of the saddle valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts.
1. Turn off the cold water supply and open the
nearest faucet to relieve the pressure. Attach the saddle valve as shown in the illustration on the next page.
Place the compression nut and ferrule (sleeve) onto the end of the tube and insert the brass insert into the tube. Connect the tube into the valve fitting. Note that the plastic ferrule should be oriented with the reduced tapered end fitting into the saddle valve. Make sure the tube is fully inserted into the valve. Tighten the compression nut securely.
NOTE: If any water leaks from the saddle valve connection, ensure that all components are sufficiently secured by tightening the compression nut. If the leak continues, remove the compression nut, ferrule, brass insert and tube from the valve, cut off 3/4 inch from the tube end, and repeat the above process.
DANGER: To protect yourself from
serious injury or fatal shock, use a battery­powered hand drill only to make the hole. DO NOT USE AN ELECTRIC DRILL.
2. Close the water supply valve by turning
the handle clockwise.
6
WATER SUPPLY A. PREFERRED INSTALLATION
1. Turn off the cold water supply.
2.
Complying with plumbing codes, install a fitting on the cold water pipe to adapt 3/8
OD tubing. A typical connection is shown in the illustrations below (parts not included). Make sure a water supply valve is used.
Preferred water supply connection (using compression fitting)
Insert (not included)
Cold water pipe
3/8
Tubing to inlet
Ferrule
Water supply valve (not included)
Typical location
Cold
water
Installation Instructions
7
B. OPTIONAL HOME INSTALLATION
(CONT.)
3. Open the main water supply valve and several
house faucets to purge air from the system. Close the faucets when water runs smoothly.
Optional water supply connection (using saddle valve)*
Pre-drill 1/4hole
Seal—make sure the seal is in place
Clamp X
Nut (2)—not required if holes in clamp are threaded
Valve
Handle
Ferrule
Compression nut
Tube
Clamp Z
Use to connect the tubing
*For 1/4OD or larger metal tubing only.
Snug valve into bracket
DO NOT OVERTIGHTEN
Some threads should be visible
Rubber gasket
Brass insert
Installation Instructions
FAUCET INSTALLATION
INSTALL THE FAUCET (CONT.)
5. Tighten the toggle screw until the base is firmly
in place and does not wobble or turn.
6. Push the 3/8” blue tube up to connect
it to the fitting on the bottom of the faucet body. It should go in about 3/4. Pull tube slightly to make sure it is secure.
7. Push the faucet body down into the faucet base
and twist clockwise until it stops into place. NOTE: You can install the faucet so the handle
is on the right or the left side.
If you want the faucet handle on the right, position the handle at the back of the faucet base before turning clockwise.
If you want the faucet handle on the left, position the handle at the front of the faucet base before turning clockwise.
8. Locate the hole at the rear
of the base. Insert set screw and begin to tighten by hand. Finish tightening with the Allen wrench provided in the packet. DO NOT OVERTIGHTEN.
Faucet body
Faucet base
Sink
Gasket
Toggle screw
3/8Black tube
INSTALL THE FAUCET
Be sure there is room underneath and above the sink to make the needed connections. Before starting, make sure there is sufficient room for the faucet base and unit. Select one of the following places to install the faucet:
A. In an existing sink spray attachment or soap
dispenser hole.
B. In a hole to be drilled in the sink top. C. In a hole to be drilled in the countertop, next
to the sink.
NOTES:
• Be sure the faucet base will fit flat against the surface at the selected location so the bottom gasket between the base and surface area will seal.
• Make sure to leave enough clearance at the back of the faucet in case you need to remove it.
Installation Steps (refer to illustration below for clarification)
1. If drilling is needed, make a 11⁄2diameter hole.
Be sure to use the proper procedure for drilling porcelain or stainless steel. Special drill bits may be needed. Consult a qualified plumber for the proper procedure.
NOTE: When drilling in stainless steel, the edges
may be sharp and could puncture the tube. Be careful to not cut yourself or damage the tube.
2. Remove the faucet body and base by turning the
base counterclockwise.
3. Push the 1/4” black tube and the 3/8black tube
onto the correct barb fittings on the faucet base. Push the 3/8blue tube through the base.
4. Align the gasket to cover the hole completely. Then
place the toggle screw on the base into the hole.
Faucet base
Sink
Gasket
Toggle screw
1/4Black tube
Faucet base
1/4Barb fitting
1/4Black tube
3/8Barb fitting
3/8Black tube
3/8Blue tube
3/8Blue tube
Mounting screw
Faucet Faucet
Faucet handle on the RIGHT Faucet handle on the LEFT
8
Installation Instructions
FILTRATION DRAIN CONNECTION INSTALLATION
Check and comply with all state and local plumbing codes as you plan.
CAUTION: The options detailed in this section are the ONLY approved installation configurations.
Do not use any drain saddle device.
OPTION A: BASEMENT ACCESS INSTALLATION
Route the drain line (1/4black line) DIRECTLY from the Reverse Osmosis system to a standpipe in the basement, bypassing the air gap provided in the faucet. The drain line may also be routed in the basement to a floor drain or washtub, provided that the air gap in the basement is maintained. Avoid dips, loops or low spots in the drain line. The basement air gap and drain installation configuration must conform to all local codes. Special air gap fittings are available from your local hardware store to connect the drain line to the top of the standpipe.
Drain line from Reverse Osmosis bypassing faucet air gap
Maintain air gap at drain point in basement
1/4Black tubing
OPTION B: DRAIN LINE ADAPTER INSTALLATION
CAUTION!
DO NOT INSTALL DRAIN LINE ADAPTER DOWNSTREAM FROM DISPOSER.
Install the provided drain line adapter under the sink as shown. The baffle-tee provided must be in place (purchase and install if necessary) to prevent a clog in the Reverse Osmosis drain line. Route the drain line (3/8black) from the faucet air gap to the drain line adapter, ensuring that there are no dips, loops or low spots in the line that could result in a clogged drain line.
The tubing must be cut to length to provide a straight routing from the faucet to the drain.
Drain noise in the sink drain is normal when the Reverse Osmosis system is operating.
FAUCET DRAIN TUBING AND WATER SUPPLY TUBING
If OPTION A: BASEMENT ACCESS INSTALLATION (see Filtration Drain Connection Installation section, above) was used, go to Step 2.
If OPTION B: DRAIN LINE ADAPTER INSTALLATION was used, connect the faucet
drain tubing by running the 3/8black tubing from the 3/8faucet barb to the drain fitting (installed in Filtration Drain Connection Installation section, above). Keep this tubing run as short and straight as possible, without loops, dips or low spots. Cut the tubing as needed and insert into the drain fitting.
1
To connect the water supply tubing:
Run the 1/4yellow tubing from the Reverse Osmosis inlet to the water supply fitting (on illustrations in the Water Supply section on page 6). Connect the tubing as applies (see Water Supply section) and tighten the nut securely.
2
9
Drain line adapter in different line from disposer
HOT COLD
Disposer
Drain line is straight
Installation Instructions
10
REVERSE OSMOSIS SYSTEM ASSEMBLY AND STORAGE TANK INSTALLATION
NOW THAT YOUR REVERSE OSMOSIS SYSTEM IS INSTALLED…SANITIZE!
Sanitize upon installation and after servicing inner parts, including replacement of prefilter, postfilter and the Reverse Osmosis cartridge. It is important to wash hands with anti-bacterial soap before handling inner parts of the system. See the Sanitization section.
CAUTION: If installing unit in new
construction, ensure that house plumbing is flushed thoroughly before opening the water supply valve. Also, before sanitizing, be sure to remove all cartridges as described in the Sanitization section. Chlorine will destroy the Reverse Osmosis cartridge.
Hold the Reverse Osmosis assembly up to the wall surface where you will install it. Mark locations for the screws. The arrows on the top of the bracket show the location of the screw holes.
1
Connect the tubing to the storage tank: Run the length of 3/8orange tubing from the tee fitting on the Reverse Osmosis module to the tank inlet fitting.
5
Wood screws are included for fastening to a wood surface. Provide other screws as needed.
2
Hang the Reverse Osmosis assembly on the screws.
3
Apply pipe thread sealing tape to the tank fitting. Insert into tank threads. Tighten with a wrench.
4
Storage
tank
To faucet
Supply line
Orange tubing
2minimum clearance for changing cartridges
Installation Instructions
PREFILTER, POSTFILTER AND RO CARTRIDGE REPLACEMENT PROCEDURE, INCLUDING SANITIZATION
Turn OFF the icemaker (if attached to the RO system).
1
Wash your hands with anti-bacterial soap.
2
Turn off water supply to RO system.
3
Remove cap from RO cartridge housing (unscrew tubing first , on some models). Use pliers to remove the RO cartridge. Place in a clean plastic bag or discard if replacing. Thoroughly wipe inside of housing and cap with a paper towel or dish brush moistened with dish soap. Rinse well. Install RO cartridge housing cap.
NOTE: Failure to remove RO cartridge during sanitization will destroy the RO cartridge.
6
Turn on RO faucet. Drain tank (may take several minutes). Turn off RO faucet.
CAUTION: Failure to close the water
supply valve or tank shut-off valve will cause water to spray or run when sumps are removed.
4
Remove the sumps. Be careful—sumps will be full of water.
Discard filters. Thoroughly wash sumps with dish soap. Thoroughly wipe inside of heads with a paper towel moistened with dish soap. Rinse well.
5
Install empty postfilter sump.
7
Fill prefilter sump with water to within 1 of O-ring. Add 2 oz. (4 Tbsp.) ordinary household bleach. Install prefilter sump.
8
Turn on water supply. Open RO faucet until water begins to flow, then close. Allow system to fill for 1 minute.
9
Open faucet and allow water to flow for 10 minutes. Close faucet for one minute more, then open and allow water to flow for another 10 minutes, or until bleach odor is gone. Turn off water supply again. Drain RO.
10
Remove sumps. Insert filters. Lubricate O-ring with food-grade silicone grease, if necessary. (Do not use petroleum jelly.) Tighten sumps securely.
11
11
Installation Instructions
12
PREFILTER, POSTFILTER AND RO CARTRIDGE REPLACEMENT PROCEDURE, INCLUDING SANITIZATION
Remove cap from RO cartridge housing. Install RO cartridge, O-ring end first. Lubricate cover O­ring with food-grade silicone grease, if necessary. (DO NOT use petroleum jelly.) Tighten cap securely.
12
If you only replaced the prefilter and postfilter, allow faucet to run 5 minutes to remove harmless carbon particles. If you replaced the RO cartridge, fill and empty the storage tank three times, until taste and odor from food-grade membrane preservative is gone.
16
Once storage tank is full, turn on icemaker.
17
Turn on water supply. Allow to fill. (May take up to four hours.) Check for leaks.
14
If you replaced the RO cartridge, also replace the flow control and screen. (Unscrew the black 1/4 line from the fitting. Remove flow control with clean knife edge. Remove screen with a clean toothpick.) Tighten the nut hand-tight and then tighten 1/4 turn with pliers. DO NOT
OVERTIGHTEN.
13
Flow control
Screen
Compression nut
1/4Black tubing
INSTALL THE BATTERY
1. Remove the lens cover from the faucet base.
Grip it from both sides and pull forward.
2. Install one CR2032 3V battery with the “+” side
down into the battery tray.
3. The amber LED light will flash 5 times, indicating
a proper installation and system reset.
4. Slide the lens cover back into the faucet base.
5. Normally, the light is off. After 6 months of use,
the amber LED light will flash every 30 seconds, indicating the time to replace the filter canister.
NOTE: The amber LED light may stop blinking if it is allowed to blink for an extended period of time. To ensure proper operation, the battery should be replaced with every filter change.
Faucet base
Lens cover
Battery “+”side down
15
To obtain replacement filters, call toll-free GE Appliance Parts at 800.626.2002 (U.S.),
800.663.6060 (Canada–English), 800.361.3869 (Canada–French) or visit the store where you purchased your reverse osmosis system.
CAUTION: Before servicing the Reverse Osmosis system, close the water supply/saddle
valve and open the RO water faucet. Allow the system to drain.
Prefilter/Postfilter Cartridge Replacement FX12P Carbon Block Reverse Osmosis Cartridge Replacement FX12M Thin Film Polyamide
The Water Test Kit
To obtain an independent laboratory water test kit, please call Legend Technical Services at
1.800.826.8553, ext. 47, and leave your contact details. They will contact you to find out what water tests you are interested in and inform you of the cost of the testing. You will then receive a kit that will include all necessary tests to properly indicate the performance level of your system. Product water should be tested a minimum of every 6 months.
Consumer Support
Troubleshooting Tips
Operating Instructions
Safety Instructions
Installation
Instructions
13
Care and cleaning of the reverse osmosis system. GEAppliances.com
About the reverse osmosis system.
14
Troubleshooting TipsConsumer Support Troubleshooting Tips
Installation
Instructions
Safety InstructionsOperating Instructions
Description of the Reverse Osmosis System
PrefilterWater from the cold supply pipe is
directed to the prefilter cartridge, which is inside the sump.
The prefilter is a replaceable sediment cartridge containing activated carbon. The cartridge reduces sand, silt, dirt, other sediments and up to
2.0 ppm of aesthetic chlorine from the water. The prefilter reduces chlorine in the water because
CHLORINE DESTROYS THE REVERSE OSMOSIS MEMBRANE. Filtered, clean, aesthetic chlorine-
reduced water flows from the prefilter to the Reverse Osmosis cartridge.
Storage Tank—The storage area holds up to 3 gallons of product water. A diaphragm inside the tank keeps water pressurized for fast flow to the faucet when drinking water is needed.
Check Valve—A check valve is built into one end of the Reverse Osmosis housing. The check valve prevents a backward flow of product water from the storage area. A backward flow could cause the Reverse Osmosis membrane to rupture.
Automatic Shutoff Valve—To conserve water, the drinking water system has an automatic shutoff. When the storage tank has filled to capacity and the drinking water faucet is closed, pressure closes the shutoff. Water flow to the Reverse Osmosis housing is shut off until drinking water is used again, and pressure drops in the Reverse Osmosis system.
What the Reverse Osmosis System Does
Reverse Osmosis removes Total Dissolved Solids (TDS) and other contaminates, as specified on page 3, from the water by diffusing it through a special membrane. High-quality product water goes directly to the drinking water faucet or to the storage tank. The system makes a good supply of drinking water each day; see Specification Guidelines. How much it makes depends on the water supply pressure, temperature and quality.
The carbon prefilter and postf ilter are replaceable cartridges. The prefilter reduces chlorine taste and odor while also filtering sediments. The postfilter reduces any other undesirable taste and odors before you use the water.
Sump
Postfilter cartridge
Prefilter cartridge
Reverse Osmosis cartridge
Reverse Osmosis housing
Turn sump this way to remove
O-ring housing
Reverse Osmosis housing cap
Sump
O-ring on top lip of sump
O-ring on top lip of sump
O-ring end
Check valve
Automatic shutoff valve
Reverse Osmosis Cartridge—The cartridge, inside the Reverse Osmosis housing, includes a tightly wound, special membrane. Water is forced through the cartridge where the membrane reduces the dissolved solids and other contaminants, as specified on page 3. High-quality product water exits the Reverse Osmosis housing and goes to the storage tank. Reject water, with the dissolved solids and other contaminants, as specified on page 3, leaves the housing and is discharged to the drain through tubing.
Postfilter—After leaving the storage area, but before going to the system faucet, product water goes to the postfilter which is inside the sump. The postfilter is also a replaceable sediment cartridge that contains activated carbon. Any remaining tastes, odors or sediments are reduced from product water by the postfilter. Clean, high­quality drinking water flows through the tubing and to the system faucet.
System Monitor—
A timer is provided in the faucet base to remind you when it is time to replace your prefilter and postfilter. Replace the filters when the amber light begins to flash in order to protect the RO membrane and keep the system functioning properly. Be sure to remove and replace the battery at the same time to reset the timer.
Flow Control—The flow control regulates the flow of water through the Reverse Osmosis cartridge at the required rate to produce high-quality water. The control is located in the Reverse Osmosis housing drain port. A small, cone-shaped screen fits over the front end of the flow control to prevent clogging due to sediments in drain water. The flow control and screen should be replaced each time the Reverse Osmosis membrane cartridge is changed.
Screen
Flow control
1/4black tubing
(to drain)
GEAppliances.com
15
Consumer Support
Troubleshooting Tips
Operating Instructions
Safety Instructions
Installation
Instructions
Before you call for service…
Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions
Installation
Instructions
16
Problem Possible Causes What To Do
Sounds you might hear Running water from the unit This is normal.
to a drain.
Water has air bubbles Air in system after installation. Will go away after water runs for a while. and is cloudy
Chlorine taste and/or The ppm of aesthetic chlorine
If the water supply contains more than 2.0 ppm of
odor in the Reverse in your water supply exceeds aesthetic
chlorine,
additional filtering of the water supply
Osmosis product water maximum limits and has destroyed to the Reverse Osmosis is needed. Correct this condition
the Reverse Osmosis membrane. before doing maintenance on the Reverse Osmosis system.
The prefilter is no longer Replace the Reverse Osmosis membrane cartridge, removing aesthetic chlorine flow control, screen, prefilter and postfilter. from the water supply.
Other taste and/or odor High-quality product water This is normal.
may have a different taste than what you’re used to.
Low water usage. Completely drain system and allow to refill.
Contamination in product
Use sanitizing procedures.
water storage.
Prefilter and postfilter
Replace the prefilter and postfilter. If taste and odor need to be changed and/or persists, replace the Reverse Osmosis cartridge, flow the Reverse Osmosis cartridge control and screen. needs to be changed.
Water leaking from Drain side of faucet air gap Inspect and eliminate restriction or plug. It is important faucet air gap hole (3/8tubing) plugged, restricted that there are no dips, loops or low spots in the drain line
or incorrectly connected to the from the faucet air gap to the drain pipe. Refer to the drain point. Filtration Drain Connection section, for proper drain
connection. If drain line adapter was used as the
drain
point, periodic inspection/cleaning is recommended.
System makes product This is normal. Water flow rate will be lower than your regular faucet. water slowly
Water supply to the Reverse Increase water pressure, precondition the water, etc., Osmosis system not within as needed to conform to specification guidelines before specifications. doing maintenance on the Reverse Osmosis system.
Prefilter cartridge plugged Replace the prefilter and postfilter.
If rate does not
with sediments and/or the
increase,
replace the Reverse Osmosis cartridge, flow
Reverse Osmosis cartridge control and screen. plugged with sediments.
Faucet light blinking Prefilter and postfilter Replace filters. Don’t forget to sanitize the system when
need replacing. replacing filters.
Timer was not reset when filters Remove and replace battery in faucet base. were replaced.
Six months have passed Battery may be dead. Replace battery. NOTE: Replacing the battery resets the and faucet light is not six-month timer, so be sure to replace the prefilter and blinking postfilter if it is time to do so.
Battery may have been Any time the battery is removed and reinserted, the removed recently. six-month timer starts over again. Do not remove
the battery unless you wish to restart the timer.
Troubleshooting Tips Save time and money! Review the chart first and you may not need to call for service.
* NOTE: Codes in the State of Massachusetts require installation by a licensed plumber
and do not permit the use of the saddle valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts.
17
Consumer Support
Troubleshooting Tips
Operating Instructions
Safety Instructions
Installation
Instructions
Optional Accessories
Parts list. GEAppliances.com
18
General Electric parts catalog.
Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions
Installation
Instructions
REF. NO. PART NO. PART DESCRIPTION GXRM10RBL
0003 WS22X10005 1/4NUT 10 0004 WS22X10026 3/8NPT X 1/4NUT ELBOW 2 0005 WS22X10006 1/4TUBE INSERT 8 0006 WS22X10038 VALVE—AUTO SHUT OFF 1 0007 WS22X10039 1/4X 3/8X 3/8TUBE TEE 1 0008 WS22X10008 3/8NUT 4 0009 WS22X10007 3/8TUBE INSERT 4 0010 WS22X10040 CHECK VALVE—1/4” INSERT 1 0011 WS22X10041 1/8NPT X 1/4FITTING 1 0012 WS03X10016 FLOW CONTROL 1 0013 WS03X10015 CONE SCREEN 1 0014 WS22X10002 3/8NPT X 3/8NUT ELBOW 2 0015 FX12M RO MEMBRANE 1 0016 WS03X10045 O-RING—RO MEMBRANE HSNG 1 0017 WS31X10025 CAP—RO MEMBRANE HSNG 1 0018 WS22X10042 1/8NPT X 1/4FITTING 1 0019 WS22X10043 ELBOW—1/4STEM X 1/4 1 0020 WS20X10006 HOUSING—RO MEMBRANE 1 0021 WS28X10039 BRACKET 1 0022 WS22X10044 CONNECTOR—3/8X 3/8MNPT 1 0023 WS32X10019 STORAGE TANK 1 0024 WX5X140 WRENCH 1 0025 WS03X10038 O-RING, SUMP HOUSING 2 0026 FX12P CARBON BLOCK CARTRIDGE 2 0027 WS20X10007 SUMP HOUSING 2 0028 WS18X10006 DRAIN LINE ADAPTER—DLA9 1 0033 WS02X10032 SCREWS, BRACKET 8 0034 WS31X10026 HOUSING HEAD 2 0035* WS15X10023* SADDLE VALVE* 1 0036 WS07X10018 TUBING—1/4X 33—WHITE 1 0037 WS07X10019 TUBING—3/8X 33—WHITE 1 0038 WS01X10013 NITRATE TEST STRIP 1 0039 WS02X10033 MOUNTING SCREWS 2 0042 WS15X10070 FAUCET BODY AND SPOUT 1 0043 WS10X10041 3/8QUICK CONNECT BASE—FAUCET 1 9999 49-50237 OWNER’S MANUAL/INSTALLATION 1
INSTRUCTIONS
* NOTE: Codes in the State of Massachusetts require installation by a licensed plumber
and do not permit the use of the saddle valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts.
To obtain replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French).
19
Consumer Support
Troubleshooting Tips
Operating Instructions
Safety Instructions
Installation
Instructions
Notes.
GE Reverse Osmosis System Warranty.
For The Period Of: GE Will Replace:
One Year Any part of the Reverse Osmosis Filtration System which fails due to a defect in materials or
From the date of the workmanship. During this limited one-year warranty, GE will also provide, free of charge, all labor original purchase and related service to replace the defective part.
All warranty service provided by our SmartWater™Authorized Servicer Network. To schedule service on-line, contact us at GEAppliances.com, or call toll-free 800.GE.CARES (U.S.), or
866.777.7627 (Canada). Please have serial number and model number available when calling for service.
n Service trips to your home to teach you how to use
the product.
n Improper installation, delivery or maintenance. n Failure of the product if it is abused, misused, used for
other than the intended purpose or used commercially.
n Use of this product where water is microbiologically
unsafe or of unknown quality, without adequate disinfection. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
n Filter cartridges, membrane cartridges and batteries
after 30 days from date of purchase.
n Damage to the product caused by accident, fire, floods
or acts of God.
n Incidental or consequential damage caused by possible
defects with this appliance.
What GE Will Not Cover:
Staple your receipt here.
Proof of the original purchase
date is needed to obtain service
under the warranty.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Warrantor: General Electric Company. Louisville, KY 40225
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
20
Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions
Installation
Instructions
Loading...
+ 44 hidden pages