GUD27ESSJ/27GSSJ
GE® 27" Unitized Spacemaker® 3.2 DOE Cu. Ft. Washer and 5.9 Cu. Ft. Dryer
Dimensions and Installation Information (in inches)
Electrical Requirements:
GUD27ESSJ Electric Dryer – This appliance should be connected to an
individual, properly-grounded branch circuit with 120/240V or 120/208V
single-phase 60 Hz electrical service and should be protected by
30-amp time-delay fuses or circuit breakers KW Rating per voltage
(240/208). This appliance is manufactured with neutral connected to
the frame. Power cord should be purchased separately.
Gas Requirements:
GUD27GSSJ Gas Dryer – This appliance should be connected to an
individual branch circuit with 120-volt single-phase 60 Hz electrical
service and should be protected by 20-amp time-day fuses or circuit
breakers. This appliance is equipped with a 4-foot long flexible U.S.
listed 20-amp power cord to match a 20-amp receptacle.
75-1/2"
52-7/8"
Installation Instructions
27" NOMINAL PRODUCT DIMENSIONS
18-5/8"
Water Inlets
Vent
12-1/2"
51°
*26-3/4"
47"
Gas Inlet
3"
3"
Note:
Gas Rated input 20,000 BTU/HR. Factory equipped for natural gas.
Tested for LP gas. LP gas supply requires a conversion kit. Have a
qualified gas technician install a conversion kit before use.
Dryers must be exhausted to the outside.
Installation Information:
For complete information, see installation instructions packed
with
the product.
For answers to your Monogram,® Cafe™ Series,
Profile™ Series or GE® appliance questions, visit
our website at geappliances.com or call GE
Answer Center® service, 800.626.2000.
36-1/2"
Drain outlet
3-7/8"
20-1/5"
* Dimension represents door closed including handle and knobs.
NOTE: With feet set at mid position, feet can be adjusted +/- 3/8".
26-3/4"
34-7/8"4-3/8"
30-7/8"
Listed by
Underwriters
Laboratories
Specification Revised 8/17
GUD27ESSJ/27GSSJ
GE® 27" Unitized Spacemaker® 3.2 DOE Cu. Ft. Washer and 5.9 Cu. Ft. Dryer
Dimensions and Installation Information (in inches)
GUD27 DRYER EXHAUST LENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust HoodTypes
Recommended
No. of 90º
Elbows
0
1
2
3
4" DIA.
4"
Rigid
Metal
56 Feet
48 Feet
40 Feet
32 Feet
4" DIA.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.
Use only
run installations
4" DIA.
Rigid
Metal
42 Feet
34 Feet
26 Feet
18 Feet
for short
2-1/2"
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal
duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). In special
installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct.
A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or flexible metal
(semi-rigid) ducting cannot be used AND where a 4" diameter can be maintained throughout the entire length
of the transition duct. Please see installation instruction packed with your dryer for complete instructions when
using flexible metal (foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer,
add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table.
For every extra 90° elbow, reduce the allowable vent system length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the chart.
The total vent system length includes all the straight portions and elbows of the system (transition duct
included)..
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl
space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage.
Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap
must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side and rear
1" front and top
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 76-1/2".
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area
equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in.
of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes,
with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" either side and rear
1" front and top
Specification Revised 8/17
Listed by
Underwriters
Laboratories