GUD24ESSM/24GSSM
GE® Unitized Spacemaker® 2.3 DOE Cu. Ft. Stainless Steel Washer and 4.4 Cu. Ft. Dryer
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRICAL REQUIREMENTS:
GUD24ESSM Electric Dryer – This appliance should be
connected to an individual, properly-grounded branch
circuit with 120/240V single-phase 60 Hz electrical
service and should be protected by 30-amp time-delay
fuses or circuit breakers. This appliance is manufactured
with neutral connected to the frame. Power cord should
be purchased separately.
NOTE: These appliances are not approved for 120-volt
operation.
GAS REQUIREMENTS:
GUD24GSSM Gas Dryer – This appliance should be
connected to an individual branch circuit with a threeprong grounding-type receptacle and 120-volt singlephase 60 Hz electrical service and should be protected
by 15- or 20-amp time-delay fuses or circuit breakers.
This appliance is equipped with a 6-foot long flexible
U.L. listed 20-amp power cord to match a 15-amp
receptacle.
GAS RATED input 10,500 BTU/HR. Factory equipped
for natural gas. Tested for LP gas.
Dryers must be exhausted to the outside.
INS TA LLATI O N IN F O RMATI O N: For complete
information, see installation instructions packed with
the product.
74-7/8"
51-3/8"
Vent
21-1/8"
* Dimension represents door closed including handle and knobs.
NOTE:With feet set at mid position, feet can be adjusted +/- 3/8".
Installation Instructions
24" NOMINAL PRODUCT DIMENSIONS
*24-5/8"
43"
18"
Water Inlets
(rear)
Drain outlet
(rear)
4-1/4"
23-3/4"
8-5/8"
37-1/4"
32-3/4"
51°
27-3/8"
(Rear view of appliance)
2-3/4"
2"
33-7/8"
Gas Inlet
For answers to your Monogram, GE Café™, GE Profile™ or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center® Service, 800.626.2000.
Listed by
Underwriters
Laboratories
Speci fication Revised 1/21
GUD24ESSM/24GSSM
GE® Unitized Spacemaker® 2.3 DOE Cu. Ft. Stainless Steel Washer and 4.4 Cu. Ft. Dryer
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
For complete information, see installation instructions packed with
your dryer.
DUCTING MATERIALS: This dryer MUST be vented with
4" diameter all rigid metal exhaust duct.
EXHAUST LENGTH CALCULATION:
1. Determine the number of 90° turns needed for your installation. If
you exhaust to the side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct
which can be tolerated is shown in the table.
For every extra 90° elbow, reduce the allowable vent system length
by 10 ft. Two 45° elbows will be treated like one 90° elbow. For the
side exhaust installations, add one 90° elbow to the chart. The total
vent system length includes all the straight portions and elbows of the
system (transition duct included).
Dryers must be exhausted to the outside.
CAUTION: For personal safety do not terminate exhaust into a
chimney, under any enclosed house f loor (crawl space), or into an
attic, since the accumulated lint could create a fire hazard or moisture
could cause damage. Never terminate the exhaust into a common duct
or plenum with a kitchen exhaust, since the combination of lint and
grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent
back drafts, bird nesting, etc. The wall cap must also be located at
least 12" above the ground or any other obstruction with the opening
pointed down.
No. of 90º
Elbows
0
1
2
GUD24 DRYER EXHAUST LENGTH*
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
4" DIA.
4"
Rigid
Metal
43 Feet
33 Feet
24 Feet
Use only
run installations
4" DIA.
for short
4" DIA.
2-1/2"
Rigid
Metal
36 Feet
26 Feet
16 Feet
For answers to your Monogram, GE Café™, GE Profile™ or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center® Service, 800.626.2000.
Listed by
Underwriters
Laboratories
Speci fication Revised 1/21