GE GFW490RPK, GFW490RPKDG, GFW490RSKWW, GFW490RSK, GFW490RPKRR Dimensions And Installation Information

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Listed by Underwriters Laboratories
GFW490RPK/RSK
GE Appliances ENERGY STAR® 4.9 DOE cu. ft. capacity RightHeight™ Design Front Load Washer with steam
For answers to your Mon ogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Specif ication Revis ed 11/16
INSTA L L AT ION INFO R M AT ION: For complete information, see installation instructions packed with your washer.
ELECTRIC RATING
120V 60Hz
28"
47"
27-3/4"
25-3/4"
24-1/2"
3/4"
7-3/4"
34-2/5"
34-1/2"
34"
28-1/2"
23"
2-1/4"
24-1/2"
For answers to your Mon ogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Listed by Underwriters Laboratories
GFW490RPK/RSK
GE Appliances ENERGY STAR® 4.9 DOE cu. ft. capacity RightHeight™ Design Front Load Washer with steam
Specif ication Revis ed 11/16
SPECIAL INSTALLATION REQUIREMENTS:
INSTA L L AT ION:
- 7" riser is included and the laundry pair can't be stacked
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side, 3" front and rear
- Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223.
Minimum Clearance other than Alcove or Closet Installations:
- Minimum clearances to combustible surfaces 0" both sides, 3" rear.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
25-3/8"
4-3/4"
22" +3/4" / -1"
Bottom of basket opening to floor.*
*With leveling leg adjust.
2-1/4"
26-5/8"