GE GFV55ESSNWW Specifications

GFV55ESSN
GE® Long Vent 7.8 cu. ft. Capacity Front Load Electric Dryer
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRIC DRYER RATING
120V/240V 5600W, 25A, 60Hz
120V/208V 4300W, 23A, 60Hz
EXHAUST OPTIONS: 4-way via rear, right, left and bottom.
CIRCUIT REQUIREMENTS: An individual, properly grounded branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required.
NOTE: Dryer wall outlet must be located within 36" of service cord entry and accessible when dryer is mounted in position.
INSTALLATION INFORMATION : For complete information, see installation instructions packed with your dryer.
28
32
39-3/4
3-5/8
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
6-1/8
R
Speci fication Created 9/19
Listed by Underwriters Laboratories
GFV55ESSN
GE® Long Vent 7.8 cu. ft. Capacity Front Load Electric Dryer
SPECIAL INSTALLATION REQUIREMENTS:
STAC K E D I N STALLATION:
Brackets for stacking dryer over washer are not included with the dryer. Order part no. GFA28KITN.
ALCOVE OR CLOSET INSTALLATION:
If your dryer is approved for installation in an alcove or closet, it will be label on the dryer back.
The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" all sides and top.*
Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET INSTALLATIONS:
Minimum clearances to combustible surfaces 0" both sides, 0" rear.
FOR MORE INFORMATION ON VENTING KITS AND ACCESSORIES, PLEASE CALL 1-800-GE-CARES.
STACKED DIMENSIONS (IN INCHES)
54-1/2
"
PEDESTAL DIMENSIONS (IN INCHES) GFP1528PNDG - DIAMOND GRAY GFP1528PNRS - SAPPHIRE BLUE GFP1528PNSN - SATIN NICKEL GFP1528SNWW - WHITE
This optional 16" pedestal raises the door opening and height of the washer or dryer.
79-1/2
28"
16"
*For improved per formance, a 1/2" clea rance is suggested on each side.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
28-7/8"
Listed by Underwriters
R
Laboratories
Speci fication Created 9/19