Installation
Dryer Venting Kit
Instructions
If you have any questions, call GE Appliances at 800.GE.CARES
(800.432.2737)
In Canada, call 800.561.3344
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT – Save these instructions for
local inspector’s use.
• IMPORTANT – Observe all governing
codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• This dryer must be exhausted to the outdoors.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not
covered under the Warranty.
• Remove and discard existing plastic or metal foil
duct.
TOOLS AND MATERIALS YOU WILL
NEED TO INSTALL EXHAUST DUCT
Ŷ
1/4" Socket & Nut Driver
Ŷ
1/4" Socket & Wrench
or visit our Website at: GEAppliances.com
WE16X29317 / GFA28DSVN
or visit www.GEAppliances.ca
WARNING
- Risk of Fire
• Clothes dryer installation must be performed by a
qualified installer.
• Install the clothes dryer according to these
instructions and local codes.
• DO NOT install a clothes dryer with flexible plastic
venting materials. If flexible metal (semi-rigid or
foil-type) duct is installed, it must be UL-listed and
installed in accordance with the instructions found
in “Connecting the Dryer to House Vent” later in
this manual. Flexible venting materials are known
to collapse, be easily crushed and trap lint. These
conditions will obstruct dryer airflow and increase
the risk of fire.
• To reduce the risk of severe injury or death, follow
all installation instructions.
• Save these instructions. (Installers: Be sure to
leave these instructions with the customer.)
WARNING
- Fire Hazard
Ŷ
Duct tape or
duct clamp
CONTENTS
Ŷ
Exhaust duct
(15-1/2" Long)
Ŷ
Exhaust duct
(12-1/2" Long)
Ŷ
Exhaust duct
(9-1/2" Long)
Ŷ
Vent hood
Ŷ
Elbow duct
Ŷ
Bracket with
adhesive
Ŷ
Access panel
This dryer MUST be vented to the outdoors.
Use only 4” rigid metal ducting for the home exhaust
duct.
DO NOT use any plastic to vent the dryer, this
includes the home exhaust duct, dryer transition
duct, or within the dryer.
DO NOT use flexible metal or metal foil ducting for a
home exhaust duct or within the dryer.
DO NOT exhaust into a chimney, kitchen exhaust,
gas vent, wall, ceiling, attic, crawl space, or
concealed space of a building.
DO NOT install a screen in or over the exhaust duct.
DO NOT install a booster fan in the exhaust duct.
Failure to follow these instructions can result in
death or fire.
31-3000209 Rev 1
02-20 GEA
Installation Instructions
BEFORE YOU BEGIN
• Remove and discard existing plastic or metal foil
duct and replace with UL-listed duct.
• Remove any lint from the wall exhaust opening.
Wall
Internal
Duct
Opening
Check that exhaust
hood damper
opens and closes
freely.
SIDE VENTING
WARNING
Disconnect dryer from electrical supply.
Wear gloves and arm guards.
Close the back opening with the access
panel included in this kit.
Failure to do so may result in fire, electrical
shock or lacerations.
• Remove the 4 screws that secure the access panel
and save. Remove the access panel.
Remove
4 screws
and save
- Fire Hazard
SIDE VENTING (cont.)
• Locate the 12-1/2” exhaust duct and elbow duct
from this kit and assemble together. Apply duct tape
around the joint to eliminate leaks between ducts.
12-1/2"
• Insert and connect the elbow/exhaust duct assembly
to the blower housing and orient the elbow for either
left or right venting.
Left Venting
Right Venting
• Locate the bracket from the kit.
• Remove the adhesive liner from the bottom of the
bracket and position it behind the elbow duct tab.
• Press down firmly to secure the bracket to the bottom
of the dryer.
Access Panel
• Detach and remove the right or left side knockout
as desired. Remove the screw that secures the
dryer exhaust duct and save. Pull the exhaust duct
out of the dryer.
Right
knockout
Exhaust Duct
Remove screw and save
Left Knockout
Elbow Duct Tab
Bracket
Saved Screw
• Using one of the screws from earlier, secure the
elbow duct tab to the bracket.
2
Installation Instructions
SIDE VENTING (cont.)
For LEFT venting:
• Locate the 15-1/2” exhaust duct from this kit.
• Insert exhaust duct through knockout opening on
the LEFT side of dryer.
• Assemble exhaust duct to elbow duct.
• Wrap the joint with duct tape to avoid air leaks.
Left
Venting
For RIGHT venting:
• Locate the 9-1/2” exhaust duct from this kit.
• Insert exhaust duct through knockout opening on
the RIGHT side of dryer.
• Assemble exhaust duct to elbow duct.
• Wra
the joint with duct tape to avoid air leaks.
Right
Venting
BOTTOM VENTING
Dryer Exhaust to the bottom of cabinet for Gas
and Electric models WITHOUT Built-In Pedestal™.
WARNING
Disconnect dryer from electrical supply.
Wear gloves and arm guards.
Close the back opening with the access
panel included in this kit.
Failure to do so may result in fire, electrical
shock or lacerations.
• Remove the 4 screws that secure the access panel
and save. Remove the access panel.
Remove
4 screws
and save
• Remove the screw that secures the dryer exhaust
duct and save. Pull the exhaust duct out of the dryer.
- Fire Hazard
Access Panel
• Install the new access panel from this kit.
• Secure access panel with 4 screws saved from
earlier.
NEVER LEAVE THE BACK OPENING WITHOUT
THE ACCESS PANEL.
Exhaust Duct
Remove screw and save
• Detach and remove the bottom knockout.
Botom Knockout
3
Installation Instructions
BOTTOM VENTING (cont.) BOTTOM VENTING (cont.)
• Locate the 12-1/2” exhaust duct and elbow duct
from this kit and assemble together. Apply duct tape
around the joint to eliminate leaks between ducts.
12-1/2"
• Insert and connect the elbow/exhaust duct
assembly to the blower housing and insert the
elbow through the bottom knockout.
• Install the new access panel from this kit.
• Secure access panel with 4 screws saved from
earlier.
NEVER LEAVE THE BACK OPENING WITHOUT
THE ACCESS PANEL.
4
Printed in USA