Product Features
The Evolve™ LED Streetlight is optimized for customers requiring a basic LED solution for local and collector roadways. GE’s unique reflective optics are designed to optimize application efficiency and minimize glare. The modern design incorporates the heat sink directly into the unit for heat transfer to prolong LED life. This reliable unit has a 50,000 hour rated life, significantly reducing maintenance needs and expense over the life of the fixture. This efficient solution lowers energy consumption compared to traditional HID fixture for additional operating cost savings.
Applications
Housing
• The modern design incorporates the heat sink
directly into the unit for heat transfer.
• Meets 3G vibration standards per ANSI C136.31-2010.
• Metal door assembly with tool less latch.
LED & Optical Assembly
• Structured LED array for optimized roadway
photometric distribution.
Evolve™ light engine consisting of reflective technology designed to optimize application efficiency and minimize glare.
• Utilizes high brightness LEDs, 70 CRI at 4000K typical.
• LM-79 tests and reports are performed in accordance with IESNA standards.
Lumen Maintenance
• Projected L87 (10K) ≥ 50,000 at Ta 25C
• Projected L70 (10K) > 100,000 at Ta 25C Based on 10,000h LM-80 data for Lumiled Luxeon-T (ZES chip family)
Ratings
/
listed, suitable for wet locations per UL 1598.
• IP65 rated optical enclosure per ANSI C136.25-2009.
• Temperature rated at –40° to 40°C.
• Upward Light Output Ratio (ULOR) = 0
• Compliant with the material restriction requirements of RoHS.
Mounting
• Slipfitter with +/- 5 degree of adjustment for leveling.
• Integral die cast mounting pipe stop feature.
• Adjustable for 1.25 in. or 2 in. mounting pipe.
Finish
• Corrosion resistant polyester powder painted, minimum 2.0 mil. thickness.
• Standard colors: Black and Gray.
• RAL & custom colors available.
Electrical
• 120-277 volt.
• System power factor is >90% and THD <20%.*
• Class “A” Sound rating.
• Integral surge protection: – For 120-266VAC per IEEE/ANSI C62.41.-1991, 6kV/3kA Location Category B3 (120 events) – Optional higher rated surge protection device available
• Photo electric sensors (PE) available for all voltages.
* System power factor and THD is tested and specified at 120V input and maximum load conditions.
Ambient Temperature Conversion Table
AMBIENT
TEMPERATURE (°C)
15 1.03 1.01 20 1.02 1.00 25 1.00 1.00 30 0.98 1.00 35 0.97 0.99
INITIAL LUMENS
FACTOR
INITIAL WATTS
FACTOR
Page 3
Ordering Number Logic
Evolve™ LED Project Grade Streetlight (ERX1)
E R X 1 5 4 0 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
TEMP
4000K
PE FUNCTION
2 = PE Receptacle 4 = PE Receptacle
w/shorting cap
5 = PE Rec. with Control A = 7-pin D = 7-pin w/shorting cap
IES
FILE NUMBERS
PROD. ID
E = Evolve R = Roadway X = Project Grade 1 = Single Module
Optical Assembly
PRODUCT
ID
ERX1 A1 525 42 3400 ERX1_A1A1540 ERX1 C1 525 61 5000 ERX1_C1A1540 ERX1 D1 A1 525 80 6600 ERX1_D1A1540 ERX1 F1 525 98 8100 ERX1_F1A1540 ERX1 G1 525 116 9400 ERX1_G1A1540 ERX1 A1 525 42 3500 ERX1_A1B1540 ERX1 C1 525 61 5400 ERX1_C1B1540 ERX1 D1 B1 525 80 6800 ERX1_D1B1540 ERX1 F1 525 98 8300 ERX1_F1B1540 ERX1 G1 525 116 9600 ERX1_G1B1540 ERX1 B1 525 52 4100 ERX1_B1B2540 ERX1 E1 ERX1 A1 525 42 3500 ERX1_A1C1540 ERX1 C1 525 61 5200 ERX1_C1C1540 ERX1 D1 C1 525 80 7000 ERX1_D1C1540 ERX1 F1 525 98 8700 ERX1_F1C1540 ERX1 G1 525 116 9600 ERX1_G1C1540 ERX1 A1 525 42 3400 ERX1_A1D1540 ERX1 C1 525 61 5000 ERX1_C1D1540 ERX1 D1 D1 525 80 6600 ERX1_D1D1540 ERX1 F1 525 98 8100 ERX1_F1D1540 ERX1 G1 525 116 9400 ERX1_G1D1540 ERX1 B1 525 52 4100 ERX1_B1D2540 ERX1 E1 ERX1 A1 525 42 3500 ERX1_A1E1540 ERX1 C1 525 61 5200 ERX1_C1E1540 ERX1 D1 E1 525 80 6800 ERX1_D1E1540 ERX1 F1 525 98 8300 ERX1_F1E1540 ERX1 G1 525 116 9600 ERX1_G1E1540 ERX1 B1 525 52 4200 ERX1_B1E2540 ERX1 E1
VOLTAGE
0 = 120-277 1 = 120 2 = 208 3 = 240 4 = 277
OPTICAL
CODE
OPTICAL
CODE
Product Tier *1 = Project Grade
See Charts for all levels
PHOTOMETRIC
TYPE
B2
D2
E2
PHOTOMETRIC
TYPE
A1 = Extra Narrow
Asymmetric B1 = Narrow Asymmetric (Medium) B2 = Narrow Asymmetric Wide Pole Spacing
C1 = Asymmetric (Short) D1 = Asymmetric Forward D2 = Asymmetric Forward
Wide Pole Spacing
E1 = Asymmetric (Medium) E2 = Asymmetric (Medium
Wide Pole Spacing
DRIVE
CURRENT
525 97 7600 ERX1_E1B2540
525 97 7600 ERX1_E1D2540
525 97 7900 ERX1_E1E2540
DRIVE
CURRENT
5 = 525mA 40 = 4000K
TYPICAL SYSTEM
WAT TAG E
120-277V
LED COLOR
TYPICAL INITIAL
LUMENS
COLOR
GRAY = Gray
BLCK = Black
D = Dimming* F = Fusing G = Internal Bubble Level I = IP 66 optical enclosure R = Additional Secondary Surge
Protection Device XXX = Special Options * When ordering Dimming PE
Receptacle 7, 9 or A, D=Dimming driver must be selected under “OPTIONS” column
NOTE: If no dimming receptacle under PE Function is selected and D+Dimming is selected under OPTIONS, 0-10v dimming leads will be provided with access through slipfitter opening in unit
NOTES:
• Max Operating Temp 40° C
OPTIONS
Lumen Maintenance
• Projected L87 (10K) ≥ 50,000 at Ta 25C
• Projected L70 (10K) > 100,000 at Ta 25C Based on 10,000h LM-80 data for Lumiled Luxeon-T (ZES chip family)
Page 4
Photometrics
Evolve™ LED Streetlight (ERX1)
ERX1 Extra Narrow Asymmetric (G1A1)
9,900 Lumens 4000K ERX1_G1A1540
ERX1 Narrow Asymmetric (G1B1)
10,100 Lumens 4000K
ERX1_G1B1540
ISO Plot
Grid Distance in Units of
Mounting Height at 30’ Initial
Footcandle Values at Grade
Grid Distance in Units of
Mounting Height at 30’ Initial
Footcandle Values at Grade
Polar Curve
7897
5928
3949
SSHS
Vertical plane through horizontal angle
of maximum candlepower at 85°
Vertical plane through horizontal angle of 0°
SSHS
Vertical plane through horizontal angle
of maximum candlepower at 85°
Vertical plane through horizontal angle of 0°
1974
2
1
6048
4535
3024
1512
2
CU Graph
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Coefficients of Utilization
0.1
012 3 4
0.0
Street Width/Mounting Height
1.0
0.9
0.8
0.7
0.6
0.5
0.4
1
0.3
0.2
Coefficients of Utilization
0.1
012 3 4
0.0
Street Width/Mounting Height
SS
HS
5
SS
HS
5
ERX1 Asymmetric Short (G1C1)
10,100 Lumens 4000K ERX1_G1C1540
ERX1 Asymmetric Forward (G1D1)
9,900 Lumens 4000K ERX1_G1D1540
Grid Distance in Units of
Mounting Height at 30’ Initial
Footcandle Values at Grade
Grid Distance in Units of
Mounting Height at 30’ Initial
Footcandle Values at Grade
5488
4115
2744
SSHS
1372
Vertical plane through horizontal angle
of maximum candlepower at 85°
Vertical plane through horizontal angle of 0°
5293
3970
2648
SSHS
1323
1
Vertical plane through horizontal angle
of maximum candlepower at 85°
Vertical plane through horizontal angle of 0°
1.0
0.9
0.8
2
1
0.7
0.6
0.5
0.4
0.3
0.2
Coefficients of Utilization
0.1
012 3 4
0.0
SS
HS
5
Street Width/Mounting Height
1.0
0.9
0.8
2
0.7
0.6
0.5
0.4
0.3
0.2
Coefficients of Utilization
0.1
012 3 4
0.0
SS
HS
5
Street Width/Mounting Height
Page 5
Photometrics
Evolve™ LED Streetlight (ERX1)
ERX1 Asymmetric Medium (G1E1)
10,100 Lumens 4000K
ERX1_G1E1540
ERX1 Narrow Asymmetric (E1B2)
8,000 Lumens 4000K
ERX1_E1B2540
ISO Plot
Grid Distance in Units of
Mounting Height at 30’ Initial
Footcandle Values at Grade
Grid Distance in Units of
Mounting Height at 30’ Initial
Footcandle Values at Grade
Polar Curve
7265
5449
3683
SSHS
Vertical plane through horizontal angle
of maximum candlepower at 30°
Vertical plane through horizontal angle of 0°
SSHS
Vertical plane through horizontal angle
of maximum candlepower at 85°
Vertical plane through horizontal angle of 0°
1816
2
1
7948
5962
3974
1987
2
1
CU Graph
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Coefficients of Utilization
0.1
012 3 4
0.0
Street Width/Mounting Height
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Coefficients of Utilization
0.1
012 3 4
0.0
Street Width/Mounting Height
SS
HS
5
SS
HS
5
ERX1 Asymmetric Forward (E1D2)
8,000 Lumens 4000K ERX1_E1D2540
ERX1 Asymmetric Medium (E1E2)
8,300 Lumens 4000K ERX1_E1E2540
Grid Distance in Units of
Mounting Height at 30’ Initial
Footcandle Values at Grade
Grid Distance in Units of
Mounting Height at 30’ Initial
Footcandle Values at Grade
5218
3918
2609
SSHS
1304
1
Vertical plane through horizontal angle
of maximum candlepower at 85°
Vertical plane through horizontal angle of 0°
9935
7451
4968
SSHS
2484
2
1
Vertical plane through horizontal angle
of maximum candlepower at 85°
Vertical plane through horizontal angle of 0°
1.0
0.9
0.8
0.7
0.6
2
0.5
0.4
0.3
0.2
Coefficients of Utilization
0.1
012 3 4
0.0
SS
HS
5
Street Width/Mounting Height
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Coefficients of Utilization
0.1
012 3 4
0.0
SS
HS
5
Street Width/Mounting Height
Page 6
Product Dimensions
Evolve™ LED Streetlight (ERX1)
20.4 in.
[519 mm]
14.2 in.
[360 mm]
FRONT VIEW
14.2 in.
[360 mm]
TOP VIEW
4.7 in.
[121 mm]
5.5 in.
[140 mm]
12.5 in. R
[318 mm R]
SIDE VIEW
20.4 in.
[519 mm]
• Approximate net weight: 15 lbs (6.8 kgs) Contact manufacturer for specific configuration weight.
• Effective Projected Area (EPA): 0.7 sq ft max (0.065 sq m)
DATA
5.2 in.
[132 mm]
Adustable for 1 1/4 to 2 in. mounting pipe
[113 mm]
(1.660 to 2.375 inch OD)
4.5 in.
[42 to 60 mm]
BACK VIEW
www.gelighting.com
GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. GE Lighting and GE Lighting Solutions, LLC are businesses of the General Electric Company. © 2014 GE.