GE AJCM10DCF Specification

Page 1
AJCM10DCF
Premium, Deluxe and Value Model Wall Case Dimensions (in inches)
GE® Series 230/208 Volt Built-in Cool-only Room Air Conditioner
WALL CASE DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Note: When installing slide-out chassis units in through-the-wall applications, keep louvers free. Do not restrict air flow areas.
Note: When installing units in through-the-wall applications. Do not restrict air flow areas.
21-13/16
For answers to your Monogram, GE Profile™ Series or GE® Series appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
26
15-5/8
Tandem
230/208V
15 Amp
Total volume and shelf area are calculated by the Association of Home Appliance Manufacturers’ standards.
Listed by Underwriters Laboratories
Page 2
AJCM10DCF
Make frame if desired or caulk between case and siding
15-3/4
26-1/8
Frame Construction
Make frame if desired or caulk between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick Frame Construction
Fill open cells with mortar or insulation
15-3/4
26-1/8
Lintel
GE® Series 230/208 Volt Built-in Cool-only Room Air Conditioner
DIMENSIONS (IN INCHES)
INSTALLATION INFORMATION : A finished opening
of 26-1/8" x 15-3/4" clear of intrusions is required. Keep clearance of 4" from side walls. Brick veneer or frame walls should have wood studding surrounding case to provide firm anchoring with screws. Case can be fastened
Make frame if desired or caulk between case and siding
Lintel
directly to brick or block walls with screws sunk in lead expansion shields.
NOTE: Units should be caulked on all four sides of case to the building exterior to assure building integrity.
WALL CASE FOR TENANT OPTION INSTALLATION When the air conditioner is offered as a tenant option, this
26-1/8
15-3/4
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
wall case provides protection against outside elements.
RAB48 – includes wall case, exterior grille,
Frame Construction
Flexible Mounting Position
steel closure panel and two layers of insulation.
STANDARD WALL CASE RAB46 Solid-sided wall case fabricated of galvanized steel with baked enamel finish. Welded areas are coated with
Lintel
a sealing compound to help resist rust and corrosion. Polymer gasket surrounds opening to assure tight weather seal. Aluminum grille (RAG13) is included. Panels on interior and between case and grille provide weather protection prior to installation of chassis. Provide firm anchoring with screws. Case can be fastened directly to brick or block walls with screws sunk in lead expansion shields.
Brick Block and Brick Frame Construction
15-3/4
26-1/8
Fill open cells with mortar or insulation
Plaster Line
Trim Molding (if desired)
For answers to your Monogram, GE Profile™ Series or GE® Series appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
Total volume and shelf area are calculated by the Association of Home Appliance Manufacturers’ standards.
Listed by Underwriters Laboratories
Page 3
AJCM10DCF
GE® Series 230/208 Volt Built-in Cool-only Room Air Conditioner
FEATURES AND BENEFITS
10,300/10,000 Cooling BTU
9.8/9.8 EER, 9.6/9.6 CEER
230/208 Volts
R-410A refrigerant
Electronic controls with remote
Electronic digital thermostat control
Filter reset
Four-Way air direction
Up-front, washable air filter
3 cooling / 3 fan only speeds
Model AJCM10DCF – Soft Gray
Delay Hrs
On Off
Cool Fan
72
Hi On Off
Mode
Med
Low
Temp
Power
Reset
+
-
On/Off
Filter
Loading...