g
2-Button Pendant Panic Sensor 868 GEN2
Installation Instructions
466-2111B • June 2008
Copyright © 2008 GE Security
Introduction
This is the GE 2-Button Pendant Panic Sensor 868 GEN2 Installation Instructions for models TX-3011-03-1 and TX-301 1-03-2.
The sensor is a supervised, wireless device designed to be used
throughout the installation site. The sensor is worn around the
neck on the strap provided. The sensor is water resistant and has
been tested to a depth of 9 ft. (3 m).
The sensor contains a transmitter and two activation buttons
(Figure 1). It does not require switches or external wiring. An
alarm is activated by pressing and holding both buttons for a
minimum of half a second. The LED on the sensor flashes for
one minute following activation.
The sensor can also transmit additional signals when a single
button is pressed; the resulting action at the panel is specific to
the panel and can be used for a variety of applications.
The sensor periodically transmits a signal so the panel can supervise the sensor. When the sensor battery voltage is low, the
sensor sends a low battery (trouble) signal to the panel.
Figure 1. 2-button pendant panic sensor
Right button
Left button
LED
Testing
The following steps describe general guidelines for testing the
sensor. Refer to your panel documentation for complete testing
details.
1. Use the panel touchpad to enter the dealer sensor test mode.
2. Press both buttons on the sensor to activate it.
3. Listen for the appropriate siren response as described in the
panel documentation.
4. Test the sensor from several loc ations within the premises to
check for consistent responses.
Note: In life safety applications, test the sensor weekly.
Battery replacement
To replace the sensor battery, do the following:
1. Remove the four housing screws on the back of the sensor
(Figure 2) and separate the cover from the base.
Figure 2. Housing screws on sensor back
Installation guidelines
For proper operation of the sensor, use the following guidelines:
• Try to keep the sensor within 100 ft. (30.5 m) of the panel.
This recommendation is only a guideline, actual sensor
range is determined during sensor testing.
• To allow users to take the sensor offsite, without the panel
reporting a supervisory or failure condition, program the
sensor into an unsupervised sensor group.
Programming
The following steps describe general guidelines for programming
(learning) the sensor into panel memory. Refer to your panel
documentation for complete programming details.
1. Set the panel to program mode.
2. Proceed to the Learn sensors menu.
3. Select the appropriate sensor group number.
4. Select the sensor number assignment.
5. When prompted by the panel, trip the sensor by pressing
and holding both buttons on the pendant for five seconds.
6. Exit program mode.
CAUTION: You must be free of static electricity while
handling circuit boards. Touch a grounded metal
surface before touching the circuit board.
2. Remove the circuit board (Figure 3) from the housing.
Figure 3. Sensor circuit board
Circuit board

2-Button Pendant Panic Sensor 868 GEN2
2
Installation Instructions
3. Remove the old battery by sliding it from the holder and
install the new battery with the positive side up to observe
polarity (Figure 4). The red LED will blink when the
battery is installed with correct polarity.
Figure 4. Battery replacement
LED
Circuit board
Battery
(positive side up)
4. Place the circuit board back into the housing, ensuring the
board is facing in the proper direction.
5. Place the back cover on the housing and secure with the four
screws. Be sure the right and left activation buttons are in
the correct location (Figure 5).
Figure 5. Back cover activation buttons
Lithium battery disposal
Expired lithium batteries are considered hazardous waste. Be
sure to dispose of old batteries according to battery directive
instructions and/or instructions from local government authorities.
Specifications
Power source 3.0 V lithium battery
Typical standby current 3 uA
Operating temperature 10 to 120°F (-12 to 49°C)
Dimensions (L x W x D) 2.50 x 1.80 x 0.50 in. (64 x 46 x 13 mm)
RF frequency 868 MHz
Compatibility GE Security control panels with 868 MHz
GEN2 receivers
Supervision rate 18 minutes
Left button
Right button
888 GE Security (888.437.3287). Toll-free in the US, Puerto Rico, and Canada.
Technical support
503.885.5700 outside the toll-free area or contact your local dealer.
www.gesecurity.com