IMPORTANT: RECEIVING INSTRUCTIONS

Visually inspect all components for shipping damage. If any shipping damage is found, notify carrier at once.

Shipping damage is NOT covered by warranty. The carrier is responsible for all repair or replacement costs resulting from damage in shipment.

IMPORTANT--USER SAFETY AND PROTECTION: In setting up systems, take care to select the proper components and design to ensure appropriate integration with your existing operations and equipment. Observe all safety measures to avoid the risk of personal injury and damage to property and equipment through improper usage.

GB ELECTRICAL, INC. CANNOT BE HELD RESPONSIBLE FOR DAMAGE OR INJURY CAUSED BY UNSAFE USE, MAINTENANCE OR APPLICATION OF ITS PRODUCTS. Please contact GB's technical service department for assistance if you are in doubt as to the proper safety precautions essential to designing and setting up your particular application.

Electric

Hydraulic

Voltage

Tester

Have only qualified personnel check motor nameplate against power availability to prevent motor burnout or dangerous electrical overloading.

Keep extension cord length to

a minimum and sizes to electric code. Do not use standard electrical equipment in an explosive atmosphere. Use grounded receptacle.

Adhere to all applicable local and national electrical codes.

Check hydraulic oil level in reservoir to prevent pump failure.

Start pump with directional valve in neutral position to prevent accidental lifting or moving of load.

NEUTRAL

Do not exceed capacity of equipment attached to pump. Use a gauge in line and do not exceed pressure rating of lowest capacity pressurized component in the system.

Upon receipt of pump...

1.Remove oil fill plug.

2.Reservoir oil level should be checked (with all cylinders retracted).

3.If necessary, add ENERPAC hydraulic oil. CAUTION: The use of other fluids may

cause extensive damage to the pump. Such damage is not covered by GB Warranty.

4.Replace oil fill plug.

WARNING: Pump overload protection is factory set. Adjustment by other than qualified personnel may cause malfunction and/or damage to component parts of the system.

NOTE: Maximum Hydraulic Pressure generated by this unit is 10,000 PSI.

Instructions

Electrical Hook-up

Hushh-Pumps

(PE22J / PE24J Series Models)

Plug in unit, use 115 volt AC grounded power source. (Unit arrives wired for 115 volt operation.) See pump nameplate for pertinent electrical requirements. (Motor rotation must be counterclockwise looking down at shroud.) Motor is wired this way at factory.

Hushh-Pumps (PE34J / PE34R

30 Series, 40 Series and 50 Series Models)

1.Check motor voltage on motor nameplate (located on side of motor housing). When shipped from factory, single phase, 110/220 volt, 60 cycle motors are wired for 110 volts. Three phase, 208/220/440 volt, 60 cycle motors have accessible motor leads under shroud. Motor rotation must be clockwise.

2.Plug cord into proper electrical outlet or provide wiring as required. To rewire single phase motors for 200 volts or three phase motors for 440 volts, see diagram on motor nameplate, or under motor cover. Have only qualified electrical personnel complete the necessary wiring.

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

 

 

 

 

 

 

 

®

 

 

 

AND INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: READ ALL PERTINENT INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

BEFORE OPERATING HIGH VOLTAGE AND ROTATING

 

MODEL NO

 

 

 

 

 

 

 

PARTS CAN CAUSE SERIOUS OR FATAL INJURY

 

 

 

 

 

 

 

 

INSTALLATION. OPERATION AND MAINTENANCE OF

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL MACHINERY SHOULD BE PERFORMED

 

SERIAL NO

 

 

 

 

 

 

 

BY QUALIFIED PERSONNEL MAKE SURE THAT THE

 

 

 

 

 

 

 

 

MOTOR AND EQUIPMENT ARE GROUNDED AND

 

 

 

 

 

 

 

 

 

 

 

 

 

PROTECTED IN ACCORDANCE WITH THE NATIONAL

 

PUMP SPECIFICATIONS

 

 

 

ELECTRIC AND LOCAL CODES SEE NEMA MG-2

 

 

 

 

SAFETY STANDARDS.

 

 

 

 

 

RATED DELIVERY

 

 

 

 

 

CAUTION: BEFORE STARTING PUMP. OPEN AIR VENT

 

 

 

 

 

 

 

 

VALVE MAINTAIN OIL TEMPERATURE BELOW 130˚F

 

 

 

 

 

 

 

 

 

 

 

 

 

USE ENERPAC OIL OVERLOAD PROTECTION

 

 

 

CU. IN./MIN.

 

330

 

240

 

42

 

FACTORY SET FOR 10,000 PSI OPERATION.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P.S.I.

 

0

 

500

 

10,000

 

MOTOR SPECIFICATIONS

 

 

 

 

 

 

USABLE OIL CAP –– 190 CU. IN

 

 

 

 

 

 

 

 

 

1

HP

1.3

 

SERVICE FACTOR

 

 

VALVE:

 

 

2-WAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115/230

VOLTS SINGLE PHASE

 

 

 

 

ELECTRIC

 

3-WAY

 

 

 

 

 

 

 

 

 

 

MANUAL

 

 

4-WAY

 

60

HZ

19/95

 

AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENERPAC, BUTLER, WISCONSIN U.S.A. DIVISION OF APPLIED POWER INC.

CA416 026

 

SPECIFICATIONS

®

AND INSTRUCTIONS

WARNING: READ ALL INSTRUCTIONS BEFORE OPERATING. HIGH VOLTAGE AND ROTATING PARTS CAN CAUSE AND INJURY. INSTALLATION AND MAINTENANCE OF ELECTRICAL MACHINERY MUST BE ERFORMED BY QUALIFIED PERSONNEL. MAKE SURE THE MOTOR AND EQUIPMENT ARE GROUNDED AND PROTECTED IN ACCORDANCE WITH THE NATIONAL ELECTRIC AND LOCAL CODES. SEE NEMA MG-2 SAFETY STANDARD. CAUTION: BEFORE STARTING PUMP, OPEN AIR VENT VALVE. MAINTAIN OIL TEMPERATURE BELOW 130˚F. USE ENERPAC OIL. RELIEF VALVE IS SET AT 10,000 P.S.I. OPERATION FOR OVERLOAD PROTECTION.

MOTOR SPECIFICATIONS: MODEL NO

 

 

1.5

 

HP

60

HZ

SERIAL NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.2

SERVICE FACTOR

 

PUMP SPECIFICATIONS

MOTOR CONNECTED

 

RATED DELIVERY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHASE

 

SINGLE

 

 

THREE

 

 

CU. IN/MIN.

 

720

 

500

 

62

 

VOLTS

115

 

230

 

460

 

P.S.I.

 

0

 

400

 

10,000

 

CIRCUIT REQUIRED

 

USABLE OIL CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

15

20

 

 

 

30 AMPS

GALLONS 2

5

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

PUMP DUTY CYCLE

 

 

VALVE

MANUAL

 

ELECTRIC

CONTINUOUS

 

8,000

P.S.I.

 

TYPE

 

 

 

 

 

 

INTERMITTENT – 50% BASED

 

2-WAY

 

 

3-WAY

ON FIVE MINS

 

10,000

P.S.I.

 

4-WAY

 

 

DUMP

ENERPAC, BUTLER, WISCONSIN U.S.A. DIVISION OF APPLIED POWER INC.

G532 026

Installing Gauge

1.Screw the gauge adaptor into valve port (38" NPT).

2.A shut-off valve is recommended when using a hydraulic gauge.

3.Screw gauge into gauge adaptor.

4.Make sure connections are tight. If necessary seal threaded connections with pipe dope or teflon tape.

Hose Connection

1.Screw 38" NPT hose end into gauge adaptor.

2.Connect hose half of high-flow coupler to cylinder half of coupler (furnished with all GB cylinders).

3.Tighten both connections.

NOTE: Make sure couplers are wiped clean when making or breaking a connection. High-flow coupler halves seal themselves against oil leakage when disconnected. Dust caps should be attached to prevent dirt from entering exposed ends of highflow coupler when disconnected.

Gauge

 

Gauge

Hose

Remove

Adaptor

 

 

 

Plug

 

 