Garland MODUKB7000100 Owner’s Manual

Induction Built-In Module-Line
RTCSmp® Griddles & Braising Pans
Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
Part Number: 4532414 9/14
Installation & Operation Manual RTCSmp Built-In Module-Line Griddle & Braising Pan
T
T
T
WARRANTY
Our warranty statements for induction products are available on-line. Please visit our website at www.garland-group.com/minisite/service to download the latest revision. If you might have any questions, please contact Garland.
THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE INSTALLED BY PROFESSIONAL PERSONNEL AS SPECIFIED
INSTALLATION
AND ELECTRICAL CONNECTION MUST COMPLY WITH CURRENT CODES: IN CANADA – THE CANADIAN ELECTRICAL CODE PART 1 AND / OR LOCAL CODES.
UNPACKING and PACKING SLIP
The packing slip attached to the shipment contains detailed information on all components. Please retain this packing slip for future reference.
USING THIS MANUAL
PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE.
This manual contains important information regarding safety, installation, operation, maintenance, and troubleshooting. They must be read entirely and carefully by the installers and operators before the equipment is installed and taken into operation. This manual must always be available for reference at the place of operation. Throughout this manual, the induction unit type “RTCSmp Built-In Module Griddle or Braising Pan” is referred to as “induction unit”.
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using only genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes and/or installation instructions provided with the product or any product that has its serial number defaced, obliterated or removed, and/or which has been modified or repaired using unauthorized parts or by unauthorized service agents. For a list of authorized service agents and/or genuine replacement parts, please visit our website at www.garland-group.com for USA and Canada. For international customers, please visit www.manitowocfoodservice.com. The information contained herein, including design and part specifications, may be superseded and is subject to change without notice.
IN USA – THE NATIONAL ELECTRICAL CODE ANSI / NFPA – CURRENT EDITION.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY, OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT
CAUTION
A SUITABLE GREASE-COLLECTING MEANS MUST BE IN PLACE BEFORE OPERATING APPLIANCE
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE
DESCRIPTION OF WARNING SYMBOLS
This symbol alerts you to a hazardous situation that WILL or COULD cause serious bodily harm or death. Be alert and implement relevant safety precautions.
his dangerous voltage warning symbol indicates a risk of electric shock and hazards from dangerous voltage.
Risk of fire or electric shock
Warning
Do not open
CAUTION
o reduce the risk of fire or electric shock, do not remove or open cover. No user serviceable parts inside. Refer servicing to qualified personnel.
his symbol alerts a hazardous situation, which if not avoided, COULD cause minor to moderate personal injury or property damage. The relevant safety precautions MUST be implemented at all times.
Electromagnetic field.
Table of Contents RTCSmp Built-In Module-Line Griddle & Braising Pan
WARRANTY ....................................................................................................................................................... 2
UNPACKING and PACKING SLIP ...................................................................................................................... 2
USING THIS MANUAL ....................................................................................................................................... 2
WARNING .......................................................................................................................................................... 2
CAUTION ........................................................................................................................................................... 2
FOR YOUR SAFETY ............................................................................................................................................ 2
DESCRIPTION OF WARNING SYMBOLS ........................................................................................................... 2
1 Safety Requirements ................................................................................................................................ 5
1.1Important Electrical & Installation Requirements ................................................................................................. 5
1.2Risk Involved By Disregarding Safety Information ............................................................................................... 5
1.3Safety Instructions for Operator .................................................................................................................................. 5
1.4Improper Use of the Equipment ................................................................................................................................. 6
1.5Unauthorized Modification and Use of Spare Parts ............................................................................................. 6
2 Components and Features....................................................................................................................... 7
2.1Application ......................................................................................................................................................................... 7
2.2Components and Features ........................................................................................................................................... 7
3 Dimensions and Technical Specifications .............................................................................................. 9
3.1Rating Plate (Module-Line Griddle & Braising Pan) .............................................................................................. 9
3.2Nomenclature and Models ........................................................................................................................................... 9
3.3Dimensions ........................................................................................................................................................................ 9
3.4Electrical Specifications ............................................................................................................................................... 10
3.5Operating Conditions ................................................................................................................................................... 10
3.6Compliances .................................................................................................................................................................... 10
4 Installation .............................................................................................................................................. 11
4.1Important Safety & Electrical Requirements ......................................................................................................... 11
4.2Installation Overview and Electrical Compartment ........................................................................................... 11
4.2.1 Installation Overview ................................................................................................................................ 11
4.2.2 Installation Clearance ................................................................................................................................ 13
4.3Location............................................................................................................................................................................. 13
4.4Ventilation ........................................................................................................................................................................ 13
4.5Grease Chute and Grease Collector ......................................................................................................................... 14
4.6Dimensions and Installation–Generator ................................................................................................................ 15
4.7Dimensions and Installation–Operation Unit ....................................................................................................... 15
4.7.1 Dimensions of Operation Unit, RTCSmp Module-Line Dual Griddle and Braising Pan ....... 15
4.7.2 Template and Installation Steps ............................................................................................................ 16
4.8Dimensions and Installation–Griddle Plate and Braising Pan ......................................................................... 16
4.8.1 Support Structure Design and Installation ........................................................................................ 16
4.8.1.1 Methods of Installation ..........................................................................................................................16
4.8.1.2 Designing a Mounting Frame (Module-Line Griddle and Braising Pan) ..............................17
4.8.1.3 Critical dimensions...................................................................................................................................17
4.8.1.4 Custom-Designed Mounting Frame Example ...............................................................................18
4.8.2 Dimensions ................................................................................................................................................... 19
4.8.2.1 Dimensions of RTCSmp Module-Line Griddle Plate ....................................................................19
4.8.2.2 Dimensions of RTCSmp Module-Line Braising Pans ....................................................................19
4.8.3 Drop-In Mounting Instructions for Module-Line Griddle Plate/Braising Pan ......................... 20
Part # 4532414 Rev 3 (9/26/14) 3
Table of Contents RTCSmp Built-In Module-Line Griddle & Braising Pan
Flush Mounting Instructions for Griddle Plate ................................................................................. 21
4.8.4
4.8.5 Flush Mounting Instructions for Braising Pan .................................................................................. 23
4.9Electrical Installation .................................................................................................................................................... 24
5 Function Test .......................................................................................................................................... 26
6 Operating Instructions .......................................................................................................................... 27
6.1Grease Collector ............................................................................................................................................................. 27
6.2Temperature Control and Display ........................................................................................................................... 27
6.3Drain Plug for Braising Pan ......................................................................................................................................... 28
6.4Considerations ............................................................................................................................................................... 28
6.5When Unit Is Not In Use ............................................................................................................................................... 28
7 Cleaning .................................................................................................................................................. 29
8 Maintenance ........................................................................................................................................... 30
9 Important Rules ...................................................................................................................................... 30
10Troubleshooting .................................................................................................................................... 31
10.1Common causes for induction unit failure ........................................................................................................... 31
10.2Problems and Possible Causes .................................................................................................................................. 32
10.3Troubleshooting with Error Codes (for Service Technicians) ......................................................................... 33
4 Part # 4532414 Rev 3 (9/26/14)
Safety Requirements RTCSmp Built-In Module-Line Griddle & Braising Pan
T
1 Safety Requirements
WARNING This product contains chemicals known to the State of California to cause cancer.
Installation and servicing of this product could expose you to airborne particles of glass wool / ceramic fibers. Inhalation of airborne particles of glass wool / ceramic fibers is known to the State of California to cause cancer.
IMPORTANT Warning labels mounted directly on the induction unit must be observed at all times and
kept in a fully legible condition.
IMPORTANT To ensure your working environment is safe, you must follow all of the safety instructions
contained in this manual, the existing national regulations for accident prevention with electrical systems, as well as any relevant company-specific safety instructions.
he induction unit should only be used if and only if the installation of the electrical system is fitted by an approved installation contractor in accordance with specific national and local regulations.
1.1 Important Electrical & Installation Requirements
This appliance component requires additional features and components to comply with appliance and electrical standards. It is the responsibility of the customer and installer to interpret and comply with all applicable safety and electrical standards. Refer to details in section 4 Installation.
1.2 Risk Involved By Disregarding Safety Information
Disregarding the safety instructions may cause harm to people, the surroundings, and the induction unit. Garland is not responsible for any damages or personal injury caused by failure to observe the safety requirements. Risks involved when disregarding safety precautions may include:
Death or injury caused by electric shock. Injury due to burns from contacting overheated cooking surface, housing, or oil and grease.
1.3 Safety Instructions for Operator
Please follow the following rules to avoid personal injuries and property damages:
Ensure the grease collector is placed correctly in place before operating the unit. The griddle plate and its housing are hot when the unit is in use. To avoid burn injuries, do not touch them
when using the induction unit.
A dirty air filter blocks the fresh air inlet. The Air Inlet Filter should be cleaned at least once a week (dish-
washer safe) or as often as necessary. Wipe the filter dry before putting it back into the unit.
Ensure no liquid can enter into the induction unit. Do not let water or food overflow the cooking area. Do not
use hoses to clean or power wash the induction unit or its vicinity.
Persons with a cardiac pacemaker should consult their doctor whether they are safe near an induction unit.
Part # 4532414 Rev 3 (9/26/14) Page 5
Safety Requirements RTCSmp Built-In Module-Line Griddle & Braising Pan
The induction unit has an internal air-cooling system. Do not block the air inlet and outlet slots with objects
such as containers. Any obstruction to air flow could cause the unit to overheat and to switch off.
The induction unit must only be used for cooking. Do no put any object other than food on the cooking
surface.
o Never heat cookware on the griddle plate / braising pan as this could damage the unit. o Do not leave any object such as paper, cardboard, or cloth on the griddle plate / braising pan as this
poses a risk of fire.
1.4 Improper Use of the Equipment
The reliability of the induction unit can only be guaranteed when it is used properly. The induction unit must always be operated within the limits provided in the technical specifications. Please refer to section 9 Important Rules of using induction equipment.
1.5 Unauthorized Modification and Use of Spare Parts
Please contact Garland if you intend to make any changes on the induction unit. For safety reasons, always use genuine parts and accessories approved by Garland. Any unauthorized modification as well as any installation of unapproved components will void all warranty.
6 Part # 4532414 Rev 3 (9/26/14)
Components and Features RTCSmp Built-In Module-Line Griddle & Braising Pan
2 Components and Features
2.1
Application
The unique RTCSmp Module-Line Griddle and Braising Pan units are specially engineered for cooking a large variety of food throughout the day. These RTCSmp module griddles and braising pans offer numerous great features including fast heat up time, uniform heat distribution, and precise temperature monitoring across the entire cooking surface. The deep pan construction of the braising pans also allow for large scale production with or without liquids. To guarantee the reliability and performance of the induction unit, please observe all safety, installation, and operation requirements mentioned in this manual.
2.2
Components and Features
Built with a robust construction, the RTCSmp Induction Module-Line Griddle or Braising Pan is modular and powerful with the revolutionary RTCSmp­Technology (Realtime Temperature Control System with Multi-Point sensing). The RTCSmp Technology monitors the energy supply, the state of the induction coil, power board, CPU, and the cooking zone in realtime. RTCSmp also limits the energy supply during peak load and its special control eliminates interference noises.
The module-line models include a number of components which allow for optimal flexibility in designing an efficient kitchen. The unique features of each component are outlined below. See also chapter 3 Dimensions and Technical Specifications.
IMPORTANT: GREASE DRAWER / BUCKET
A suitable grease drawer or bucket must be custom built for the RTCSmp Induction Module-Line Griddle or Braising Pan. Refer to section 4.5 Grease Chute and Grease Collector.
CAUTION
Induction Generator
(Griddle / Braising Pan):
A suitable grease-collecting means must be in place before operating appliance.
Engineered specifically for modular kitchen designs. | All connections such as the mains cable, operation cable, CAN/BUS cable, and sensor cable can be connected externally through plug connections. | Closed aluminum housing with an integrated cooling fan to keep electronics cool. | Integrated air guiding system to direct exhaust air out of the housing.
Types: (1x) IN/MO/GR 7000 or IN/MO/GR 10000
Part # 4532414 Rev 3 (9/26/14) Page 7
Components and Features RTCSmp Built-In Module-Line Griddle & Braising Pan
Operation Unit (Griddle / Braising Pan):
Griddle Plate (MODUGR Model):
The operation unit is to be mounted separately from the generator and the griddle/braising pan. | The unit is connected to the generator via a RJ-45 cable. | The control regulates the temperature in an increment of 5
o
450
F / 35 - 230oC. | Adjust the temperature setting simply by turning the knob. |
o
F(1oC), from 95 -
The set and current temperatures are shown via the digital display. The digital displays show temperatures in either Fahrenheit or Celsius (specified when ordered). | IR interface with diagnostic system for service.
Types: (1x) IN/MO/GR
o
F or IN/MO/GR oC
Included:
(2x) plastic knobs, (1x) dual-panel overlay
Compact and low profile. | Durable griddle plate surface with a polished HPCR­INOX coating, which is resistant to abrasion, chemical, corrosion, and heat. | Curvatures and smooth surface enable optimum cleaning. | Integrated grease chute allows for easy draining of grease and cleaning. | Energy transfer is carried out by the coils located beneath the griddle plate. | Twelve (12) sensors are incorporated for accurate temperature control. | Integrated cooling fan and air guiding system to direct exhaust air out of the housing. | Included a mounting frame for flush-mounting application. The mounting frame package includes a leveling plate and a high temperature silicone sealing gasket.
Braising Pan (MODUKB Model):
Cable Kit (Griddle / Braising Pan):
Griddle Plate Accessories Included: (1x) Scrubbing Pad, (1x) Griddle Spatula, (1x) Griddle Plate Splash Guard, (2x) Dishwasher-safe Air Intake Filter
Options of three (3) different pan depths and capacities. | Durable surface with a polished HPCR-INOX coating, which is resistant to abrasion, chemical, corrosion, and heat. | Curvatures and smooth surface enable optimum cleaning. | Integrated drain spout allows for easy collection of products or waste. | Energy transfer is carried out by the coils located beneath the braising pan. | Twelve (12) sensors are incorporated for accurate temperature control. | Integrated cooling fan and air guiding system to direct exhaust air out of the housing.
Braising Pan Accessories Included: (1x) Scrubbing Pad, (1x) Griddle Spatula, (1x) Drain Plug, (2x) Dishwasher-safe Air Intake Filter
Drain Plug Sizes: (i) 80mm/3.15” plug for 65mm/2.5” deep braising pan; (ii) 115mm/4.53” plug for 100mm/4” deep braising pan; (iii) 165mm/6.5” for 150mm/6” deep braising pan.
One (1) 2.5-meter cable kit for 208V or 400V, is included. Kit includes a RJ-45 cable, coil cable(s), sensor cable(s), and a cable for the fan .
Options: 4-meter Cable Kit (208V); 4-meter Cable Kit (400V); 6-meter Cable Kit (208V); 6­meter Cable Kit (400V)
8 Part # 4532414 Rev 3 (9/26/14)
Dimensions and Technical Specifications RTCSmp Built-In Module-Line Griddle & Braising Pan
T
3 Dimensions and Technical Specifications
3.1 Rating Plate (Module-Line Griddle & Braising Pan)
he rating plate contains important information such as model number, serial number, and electrical specifications. The rating plate is affixed to the side of the induction generator, next to the mains connection.
3.2 Nomenclature and Models
Series Style Function Power
(Watt)
MO =
module-line
DU = dual
GR = Griddle
KB = Braising Pan
7000 10000 7000 10000
Depth of Braising Pan
65 mm 100 mm 150 mm
Models
MO DU GR 7000 MO DU GR 10000 MO DU KB 7000 65 MO DU KB 7000 100 MO DU KB 7000 150 MO DU KB 10000 65 MO DU KB 10000 100 MO DU KB 10000 150
3.3 Dimensions
For technical drawings and dimensions of the operation unit and mounting frame, see section 4 Installation.
Component Model Dimensions, inch (mm)
Generator
Griddle Plate
Braising Pan
MO DU GR MO DU KB
MO DU GR
MO DU KB 7000 65 MO DU KB 10000 65
MO DU KB 7000 100 MO DU KB 10000 100
MO DU KB 7000 150 MO DU KB 10000 150
23.62” x14.17” x2.58” (600 x 360 x 65.5mm)
Griddle Plate Dimensions, inch (mm)
Overall: 25.83 x 24.21 x 5.67 (656 x615 x144) Cooking Surface Area: 24.33 x 22.72 (618 x 577)
Braising Pan Dimensions inch (mm)
Overall:
25.83 x24.21 x11.02 (656 x615 x280) Cooking Surface Area:
24.33 x22.72 (618 x577) Overall:
25.83 x24.21 x11.02 (656 x615 x280) Cooking Surface Area:
24.33 x22.72 (618 x577) Overall:
25.83 x24.21 x11.02 (656 x615 x280) Cooking Surface Area:
24.33 x22.72 (618 x577)
Depth of Pan inch (mm)
2.5 (65) 5 (19)
4 (100) 8.5 (32)
6 (150) 13 (49)
Pan Capacity Gal (Litres)
Part # 4532414 Rev 3 (9/26/14) Page 9
Dimensions and Technical Specifications RTCSmp Built-In Module-Line Griddle & Braising Pan
/
/
/
/
T
3.4 Electrical Specifications
Model Voltage Power Conductor Size #Cook Zones
60Hz 7000W (2x3500 W)/ 22A AWG 10
2
60Hz 10000W (2x5000 W)/ 30A AWG 8
2
60Hz 7000W (2x3500 W)/ 22A AWG 10
2
60Hz 10000W (2x5000 W)/ 30A AWG 8
2
MO DU GR 7000
MO DU GR 10000
MO DU KB 7000
MO DU KB 10000
208 V AC / 3Ph 400 V AC / 3Ph/ 50Hz 7000W (2x3500 W)/ 11A 1.5mm2 440 V AC / 3Ph/ 50Hz 7000W (2x3500 W)/ 10A 1.5mm2 208 V AC / 3Ph 400 V AC / 3Ph/ 50Hz 10000W (2x5000 W)/ 16A 2.5mm2 440 V AC / 3Ph/ 50Hz 10000W (2x5000 W)/ 15A 2.5mm2 208 V AC / 3Ph 400 V AC / 3Ph/ 50Hz 7000W (2x3500 W)/ 11A 1.5mm2 440 V AC / 3Ph/ 50Hz 7000W (2x3500 W)/ 10A 1.5mm2 208 V AC / 3Ph 400 V AC / 3Ph/ 50Hz 10000W (2x5000 W)/ 16A 2.5mm2 440 V AC / 3Ph/ 50Hz 10000W (2x5000 W)/ 15A 2.5mm2
3.5 Operating Conditions
Max. Tolerance of Nominal Supply Voltage +6 /-10 % Network Impedance (Zmax.) 0.25Ω Supply frequency 50/60 Hz Amperage Nominal Value: 400V, 3Ph 10A for the 7kW built-in generator (4x 1.5mm2)
Amperage Nominal Value: 208V, 3Ph 20A for the 7kW integrated generator (4x AWG 10)
Ingress Protection class Maximum Ambient Temperature In Storage > -4°F to +158°F (-20°C to +70°C)
Maximum Relative Air Humidity In Storage > 10% to 90%
Set Temperature Range 95 - 450oF (35 - 230oC)
emperature Regulator Potentiometer 10 kOhm
Clearance from materials Min. 1.57”(40mm) for air intake and exhaust openings
Induction Generator: Maximum fan air flow: 70.63 cfm (120 m3per hour). Minimal opening of 10.08 sq. in. (6500
2
mm
) is required around the fan.
3.6 Compliances
15A for the 10kW built-in generator (4x 2.5mm
29A for the 10kW integrated generator (4x AWG 8)
IPX0 (Protection by customer is required.)
In Operation >+ 41°F to +104°F (+5°C to +40°C)
In Operation > 30% to 90%
Min. 0.39”(10mm) for side clearance
North American models:
ETL recognized* in compliance with UL 197, CSA C22.2 No.109, NSF-4. Complies with FCC part 18, ICES-001
CE models comply with the latest European Norms:
EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV)
*see section 4.1 Important Safety & Electrical Requirements
2
)
10 Part # 4532414 Rev 3 (9/26/14)
Installation RTCSmp Built-In Module-Line Griddle & Braising Pan
4 Installation
4.1 Important Safety & Electrical Requirements
This appliance component requires additional features and components to comply with appliance and
electrical standards. It is the responsibility of the customer and installer to interpret and comply with all applicable safety and electrical standards.
o This product requires the addition of:
A suitable non-flammable electrical enclosure; a means to conceal and protect
components and wiring.
Grounding and bonding to the enclosure. Markings to show appliance ratings and end manufacturer information. Investigation by local electrical authority. Warning and caution labels and other
markings required by electrical and safety standards could be provided by local authority.
o Depending on the application and configuration of this product, consider the addition of:
Field supply connection terminals (terminal block). Branch circuit protection (breakers). Fans, ventilation or cooling systems and controls.
The installation, including electrical installation, must be carried out by registered installation contractors
only. The contractors are responsible for interpreting all instructions correctly and performing the installation in compliance with national and local regulations. The warning signs and rating plates on the cooking equipment must strictly be followed.
Read ALL SECTIONS carefully, comply with all requirements listed and ensure all inspection is done by
qualified personnel.
Refer to the technical data given in section 3 Dimensions and Technical Specifications. Induction equipment that is not installed correctly will have warranty voided. See Warranty, p.2.
4.2 Installation Overview and Electrical Compartment
4.2.1 Installation Overview
Operators and kitchen staff must have safe access to the custom built grease pan or bucket installed under the griddle or braising pan. The induction equipment and wiring must be installed in electrical compartment(s) inside the cabinet (Figure B). The illustration below shows a simplified representation of an installation.
IMPORTANT To ensure reliability of the induction unit, the cabinet/compartments must have sufficient
ventilation for the exhaust. Buildup of hot exhaust air will cause the unit to reduce power or to switch-off. See section 3.5 Operating Conditions.
Part # 4532414 Rev 3 (9/26/14) Page 11
Loading...