GB
Purpose:
Please note:
Excess growth of algae:
Contents:
GARDENA UVC Pressure Filter Set PF 10000 S / PF 15000 S
Welcome to GARDENA aquamotion...
Translation of the original instructions from German. Please read and carefully follow these operating instructions. Use these instructions to get to know the UVC Pressure Filter Set, how to use it correctly and the safety instructions.
For safety reasons, children and young people under 16 years of age and people who are not acquainted with these Operating Instructions must not use this UVC Pressure Filter Set.
v Please keep these operating instructions in a safe place.
1. Range of Uses for Your GARDENA UVC Pressure Filter Set . 13
2. Safety Instructions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3. Function
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4. Assembly
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5. Initial Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6. Putting out of Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7. Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
8. Trouble-Shooting
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
9. Accessories
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
10. Technical Data
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
11. Service / Warranty
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1. Range of Uses for Your GARDENA UVC Pressure Filter Set
The UVC Pressure Filter Set is intended for private use in domestic gardens and allotments and should only be used out of doors for cleaning garden ponds with and without fish.
PF 10000 S: PF 15000 S:
for ponds with a volume of for ponds with a volume of up to 10000 l without fish / up to 15000 l without fish /
5000 l with fish 7500 l with fish
The GARDENA UVC Pressure Filter Set cleans the pond water biologically and mechanically and reduces the growth of algae. Algae is bound together and pathogens (particularly in fish ponds) are destroyed.
The UVC Pressure Filter Set is not suitable for industrial use or in combination with chemicals, food, easily combustible and explosive substances.
Pond and Filter Tip
Garden ponds are not as deep as natural water features. The lack of depth means that a garden pond heats up and cools down much more quickly. These changes in temperature and environmental factors such as fertilisers, plant residues etc., are among the main causes of excess levels of nutrients and hence of growth of algae.
14
GB
In garden ponds the density of fish stock per cubic metre is usually higher than in natural ponds. As the fish usually also receive more food than in their natural environment, the amount of pollution due to excrement is very high.
Excess growth of algae, as well as the high level of pollution due to fish excrement causes a lack of oxygen in your pond; its biological balance has been disturbed.
Problem: the level of nutrients in your pond is too high. The most effective solution to this problem is to decrease the
level of nutrients available by means of a biological process and to remove excess nutrients while at the same time increasing the oxygen supply.
The growth of algae can be restricted by installing a filter. Floating substances (e.g. floating algae), which cause the water to be murky, are filtered out and the water is purified. This helps the pond to regain its biological balance. However, existing algae (e.g. thread algae) visible at the time of installation must be skimmed off (e.g. with the GARDENA combisystem Pond Net, Art. No. 7933).
Where possible, the filter should be kept in permanent operation and not be allowed to dry out.
When newly installed, the UVC-Pressure Filter Set only reaches its full biological cleaning effect after a few weeks. Extensive bacteria activity only takes place from a temperature of + 10°C or above.
High density of fish stock:
Level of nutrients:
Installing a filter:
Note:
2. Safety Instructions
V The safety instructions on the GARDENA UVC Pressure Filter Set must be followed!
WARNING! V Read the operating
instructions before using the equipment for the first time!
DANGER ! V Ultraviolet radiation.
Protect eyes from flash.
This radiation is harmful to eyes and skin. Never operate the UV unit when the
housing has been removed.
Electrical safety:
DANGER ! Electric shock! V Disconnect the pump and the
UVC device from the power supply before carrying out work.
vv
Inspect the equipment before use to ensure that the pump and the UVC unit, especially the power cable and plug, are
undamaged. Do not use a damaged UVC unit or pump. Do not use the light if the connection lead,
glass tube or the housing of the UVC unit appear to be defective.
If the pump or UVC unit is damaged, please have them checked by our GARDENA Service Centre or an authorised electrician.
The UVC-unit and the pump must be operated via a residual-current device (FI-switch) with a nominal fault current 30 mA (DIN VDE 0100­702 and 0100-738).
v Please ask your electrician for his advice.
15
GB
Mains power cables should not have a smaller cross-section than a rubber sheathed cable of the designation H05 RNF. Extension cables must meet the requirements of DIN VDE 0620.
The information on the model plate of the UVC unit must match the power supply.
The connection cable of the UVC-unit and the pump cannot be replaced. If the cable is damaged the UV unit must be scrapped.
Do not use extension leads, connection leads or adaptors without a protective contact.
The pump must not be operated when there are people in the water. Swimming pools and garden ponds should be designed according to international and national design regulations.
v Please ask your electrician for advice. Never carry the UVC-unit and the pump by the
cable. Do not pull on the cable to unplug the plug from the socket.
Please protect the cable from heat, oil and sharp edges. Make sure that connection points remain dry.
Always unplug the equipment when dis­mantling the set, when it is not in use and before maintenance.
v Always disconnect the UVC unit and the
pump from the mains before undertaking any work.
For Austria
In Austria power cables should correspond to ÖVE-EM 42, T2 (2000) /1979 § 22 according to § 2022.1. According to this standard units used in swimming pools and ponds should only be operated via an isolating transformer.
v Please contact your electrician.
For Switzerland
In Switzerland mobile appliances which are used outdoors, must be connected via a residual-current device.
Note:
Operation of the pressure filter is only allowed with pumps to a max. operating pressure (see Technical Data).When using a pump with a higher operating pressure, the filter can leak, leading to the pond emptying.
Do not subject the pressure filter to direct sunlight and secure against falling in.
Never operate the UVC unit without water throughput.
Never let the pump run dry; running dry generates heat and will damage the pump.
Sand and other abrasive substances in the liquid cause increased wear and reduce the output of the pump.
The temperature of the liquid used must not be below 4 °C or above 35 °C.
Safety switch:
If the UVC light overheats, it is switched off by the built-in thermal protection switch. The UVC light switches itself on again automatically when it has cooled down sufficiently.
Due to the integrated safety switch the lamp only comes on when the UVC unit is properly installed.
Positioning the filter:
v Stand or bury the filter housing in a stable
position at least 2 m away, next to the
garden pond. The filter output must be positioned higher
than the surface of the pond.
Bacterial Activity:
The filter system is a biological system and therefore, when newly installed, needs a few weeks until it is fully effective.
If possible, the filter should be in permanent operation from spring to autumn and should not dry out.
16
GB
3. Function
!
Water intake
Universal connection (3/4” –11/2” ) for the pump supply hose in the pond.
"
UVC-radiation
The pond water, which has already undergone preliminary treatment, is subjected to short wave UVC-light (ultraviolet rays). During this process, the algal growth is reduced and germs which cause disease in fish ponds are killed.
§
Mechanical filtering
Dirt in the pond water is retained mechanically by the large outer surface of the filter sponges in the filter.
$
Biological treatment
The biological pond water treatment takes place in two different areas of the filter:
Filter sponges / bio-surface elements:
This promotes the growth of micro-organisms which guarantee the conversion of ammonia into nitrate via nitrite (nitrification).
Lava stone:
This supports the growth of anaerobic micro-organisms which promote denitrication (reduction of nitrate to nitrogen).
%
Water discharge with contamination display
Transparent universal connection (3/4” –11/2” ) for returning the treated water with contamination display for simple recognition of the need for cleaning.
4. Assembly
1. Cut the connecting hose 1between pump and filter to size accordingly.
2. Screw the adapter
4
(pre-mounted) and connecting nipple
3
on the pump.
3. Push the hose clamp
2
onto the connecting hose 1.
4. Slide the connecting hose
1
onto the connecting nipple 3.
5. Secure the connecting hose
1
with the hose clamp 2.
Join the connecting hose to the pump:
1
2
3
4
"
§
$
!%
Loading...
+ 10 hidden pages