Gardena 500 S, 7644, 1000 S, 7645 Operating Instructions Manual

D
GB
S
NL
F
I
E
DK D
GB
S
NL
F
I
E
DK
D Gebrauchsanweisung
Wasserspielpumpen-Set
GB Operating Instructions
Fountain Pump Set
F Mode d’emploi
Pompe pour jets d’eau
NL Gebruiksaanwijzing
Waterspelpompset
S Bruksanvisning
Pumpset för fontän
I Istruzioni per l’uso
Set pompa per giochi d’acqua
E Manual de instrucciones
Conjunto de bombas de efectos acuáticos
P Instruções de utilização
Conjunto para bombas de jogos de água
DK Brugsanvisning
Springvandspumpesæt
500 S Art. 7644
1000 S Art. 7645
9
GB
8
GB
2. Safety instructions
GARDENA Fountain Pump Set 500 S / 1000 S
Welcome to the Garden of GARDENA ...
Please read the Operating Instructions carefully and comply with them. Use these operating instructions to familiarise yourself with the pump, its proper use and the safety instructions.
v Keep these operating instructions in a safe place.
Contents 1. Where to use your GARDENA Fountain Pump set . . . . . . . . . 8
2. Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3. Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4. Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5. Storing your Fountain Pump Set . . . . . . . . . . . . . . . . . . . . . . 10
6. Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7. Trouble-shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
8. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
10. Service / Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1. Where to use your GARDENA Fountain Pump set
The GARDENA Fountain Pump is intended for domestic use. It is not designed for operating watering equipment and accessories or irrigation systems. The pump can be used both indoors and outdoors.
The GARDENA Fountain Pump is not suitable for continuous operation in industrial applications. Corrosive, easily combustible, aggressive or explosive substances (such as gasoline, petroleum or nitro thinners), or saltwater must not be pumped, nor must foodstuffs or drinking water.
Please note
Intended Use:
For safety reasons, children under 16 as well as persons not familiar with these operating instructions must not use this pump.
The pump must not be operated when there are people in the water.
Swimming pools and garden ponds should be designed according to international and national design regulations.
v Please consult a professional electrician. Before operating the pump, look to see if there
is any damage to the pump (esp. regarding power cable and plug).
The connection cable of the pump cannot be replaced. If the cable is damaged the pump must be scrapped.
Do not use the power cable to carry the pump or to pull the plug out of the socket.
Protect the power cable from heat, oil and sharp edges.
User instructions:
Never let the pump run dry; running dry generates heat and will damage the pump.
The temperature of the liquid used must not be below 4 °C or above 35 °C.
Sand and other abrasive substances in the liquid cause increased wear and reduce the output of the pump.
Please observe the local noise prevention regulations.
3. Assembly
1. Screw the nozzle tube 2with side outlet into the socket 1.
2. Plug the nozzle tube
3
with regulating hole into the nozzle
tube
2
.
3. Plug further nozzle tube(s)
4
into the nozzle tube 3as
required.
4. Plug the fountain socket 5into the top nozzle tube 4.
5. Insert the desired fountain insert into the fountain socket 5:
Only on the 1000 S
a) cascade b) water bell c) jets of water
Side outlet
2
:
Other features (e. g. a gargoyle) can be connected to the side outlet of the nozzle tube 2[9 mm / 13 mm (1/2”)] .
v The water quantity can be adjusted at the side outlet of the
nozzle tube 2by adjusting the extent to which the regulating hole
b
of the nozzle tube 3is covered by the side outlet 2.
5
4
3
2
1
b
a) Cascade into a bayonet socket. b) / c) Push in the Water Bell / Fleur-de-Lis until they click
audibly home.
Fit the pump:
Electrical Safety:
DANGER ! Electric shock ! v Always disconnect the pump
from the mains before under­taking any work on it.
The pump should be operated via a residual current device with a residual current rating of 30 mA (DIN VDE 0100-702). The pump must be placed on solid, even ground.
v Please ask your electrician for his advice. Mains power cables should not have a smaller
cross-section than a rubber sheathed cable of the designation H05 RN-F3G0,75. Extension cables must meet the requirements of DIN VDE 0620. Check line voltage. Data indicated on the type plate must match technical data of the mains supply.
Please unplug the pump after operation and before carrying out any maintenance works.
11
GB
10
GB
4. Initial Operation
1. Place water feature pump on a firm base in such a way that the filter housing 6is completely covered by water.
2. Plug mains plug into an AC power socket.
Warning: Pump will start immediately.
3. Use the nozzle tube regulating hole 3to set the desired amount of water for the Fountain (see 3. Assembly “side outlet”).
5. Storing your Fountain Pump Set
1. Before the frosty season begins, take the pump out of the pond, clean it and store it in a frost-free place.
2. To avoid difficulties when starting up in the spring, we recom­mend storing the pump in a frost-free location in a container filled with water.
The mains plug must not be submerged.
The product must not be added to normal household waste. It must be disposed of properly.
6. Cleaning
1. Take the Fountain Pump out of the water.
2. Unscrew the nozzle tube and the socket 1.
3. Take the fountain insert out of the fountain socket
5
4. Release the catches 7and open the filter housing 6.
5. Remove the pump from the filter housing 6.
6. Clean the nozzle tube and fountain insert in clean water.
7. Clean the filter housing 6with a water jet.
8. Reassemble the Fountain Pump in the reverse order.
5
1
7
6
CAUTION! Electric shock ! Risk of injury due to mains electricity. v Before cleaning the pump, unplug the it from
the mains.
Cleaning the fountain and filter housing:
Disposal:
(in accordance with RL2002/96/EC)
The pump should be stored out of the reach of children.
Storage:
3
6
Switching the Fountain Pump on:
7. Trouble-shooting
1. Remove the pump from the filter housing (see 6. Cleaning).
2. 500 S: Release the catches 8on the pump housing 9and
remove the pump housing 9. 1000 S: Turn the pump housing 9anticlockwise and pull it
vertically off the motor housing
0
(bayonet socket).
3. Pull impeller unit Aout of the motor housing 0and clean.
4. Push cleaned impeller unit Aback into the motor housing 0.
5. 500 S: Press the pump housing 9on to the motor housing 0. 1000 S: Press the pump housing 9vertically on to the
motor housing 0and tighten it clockwise. Make sure that the O-ring
B
is seated correctly.
Fault Possible cause Remedy No water feature operating Mains plug not plugged in. v Plug in mains plug.
Impeller unit is blocked. v Clean pump. Water feature insert is dirty. v Clean water feature insert.
and nozzle pipe. Filter housing dirty. v Clean filter housing. Open the side outlet. v Close the side outlet using
the regulating hole.
CAUTION!
If any other faults arise, please contact GARDENA Service.
8. Accessories
Lighting the Fountain and the bank area. art. 7952
art. 7954 art. 7958
Start water features and lighting from the terrace or your living room. art. 7874
GARDENA radio control set
GARDENA Underwater lights UL 20 / UL 35 / UL 20 S Set
Work on the electrical parts must only be carried out by GARDENA Service Centres.
Reduced water feature
8
9
A
0
B
Cleaning the pump:
CAUTION! Electric shock! Risk of injury due to mains electricity. v Before fault-finding, unplug the pump at the
mains.
Loading...
+ 4 hidden pages