2. For Your Safety
According to DIN VDE (German Electrical Engineers’ Associa­tion) 0100, submersible pumps may only be used in swimming pools, garden ponds, and fountains if the pump is operated via a residual-current device with a residual-current rating of 30 mA. The pump must not be operated when there are persons in the swimming pool or garden pond.
For safety reasons we recommend that you always operate the submersible pump via a residual-current device (DIN VDE 0100-702 and 0100-738).
v Please contact your electrician.
In Austria, according to ÖVE B/EN 60 555 part 1 to 3, pumps which are used in swimming pools and garden ponds, and equipped with firm power cable should be fed via an ÖVE approved isolating transformer – rated voltage must not exceed 230 V.
In Switzerland mobile appliances which are used outdoors, must be connected via a residual-current device.
According to DIN VDE (German Electrical Engineers’ Associa­tion) 0620, mains power cables must not have a smaller cross­section than the rubber-sheathed cables of the designation H05 RNF. The cable length must be at least 10 m.
Data indicated on the type plate must match technical data of the mains supply.
v Take care that the electrical connections are made within dry
area, protected from flooding. Protect plug and power cable from heat, oil and sharp edges. v Don’t use the power cable for plugging off. The power cable or the float switch must not be used for mount-
ing or relocating the pump. For submerging or lifting/ securing the pump, fix a rope to the pump’s carrying handle.
Extension cables must meet the requirements of DIN VDE 0620.
v Before operating the pump, first make a visual check, if there
is any damage of the pump (esp. regarding power cable and
plug). v Observe the minimum water level and the max. delivery
height (see 8. Technical Data). A damaged pump must not be used. v In case of damage, please have the pump checked by our
GARDENA Service Centre.
During manual operation, the pump must be switched off as soon as all the liquid has been pumped away.
v Observe the pump at all times during manual operation.
v Clear the outlet line before use.
Dry-running operation causes increased wear and is to be avoided. Therefore, in manual operation the pump must be immediately unplugged when water fails to flow.
Residual-current device
In Austria
In Switzerland
Mains power
Visual check
Manual operation
Notes on use
Intended use
Liquids to be pumped
Please note
GARDENA Submersible Pump 5000 S
Welcome to the garden of GARDENA ...
Please read these operating instructions carefully and observe the notes given. Use the instructions to familiarise yourself with the submersible pump, its correct use, and the notes on safety.
For safety reasons, children under 16 as well as persons not familiar with these operating instructions should not use this submersible pump.
v Keep these operating instructions in a safe place.
1. Applications Range of Your GARDENA Submersible Pump
. . 10
2. For Your Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3. Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4. Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5. Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6. Trouble-Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
7. Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
8. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
9. Service
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1. Applications Range of Your GARDENA Submersible Pump
GARDENA Submersible Pumps have been designed for private use around your house and garden. They are predominantly desti­nated for drainage after flooding, transfer of liquids, draining con­tainers, taking water from wells and shafts, draining boats and yachts as well as for water aeration and circulation for a limited period of time.
Liquids which can be handled by the GARDENA Submersible Pump are the following: clean and slightly contaminated water (max. particle size 5 mm), swimming pool water (prerequisite is the recommended dosage of additives) and soapy water.
The pump is fully submersible (waterproof sealed) and can be immersed in the liquid down to a depth of 9 m.
The GARDENA Submersible Pumps are not designed for continuous operation (e.g. continuous circulating opera­tion) in a pond. Your pump’s life will be shortened corre­spondingly by such operation. Corrosive, easily combustible or explosive substances (e.g. gasoline, petroleum, nitro thinner), fats, oils, salt-water and waste water of toilets and urinals must not be pumped. The temperature of the liquid handled should not exceed 35 ° C.
Contents
Page 3
13
G
12
G
Avoid running of the pump for more than 10 min. against closed delivery side of the pump.
Sand and other abrasive substances cause increased wear and reduce the pump’s output.
Take care that the pump is located where the inlet openings at the suction base are obstructed neither completely nor partly.
Stand the pump on a brick if using in a pond.
The pump is automatically switched off on overheating by the built-in thermal motor protector. After having cooled down, the motor automatically switches on again (see 6. Trouble Shooting).
The automatic deaerating valve eliminates any air pockets in the pump. If the water level drops below the vent valve, some water flows penetrates outside through the vent valve
4
. This is not a defect of your pump, but serves to deaerate the pump.
Thermal motor protector
Automatic deaerating valve
3. Initial Operation
13 mm (1/2”)
Hose diameter 15 mm (5 / 8 ) 25 mm (1) 38 mm (1 1/2”)
19 mm (3/4” )
Hose connection of universal fitting
7
Hose connection Cut off topmost Do not cut off Cut off top two
nipple ata. any nipples. nipples at b.
The following connection kits are required for 13 mm to 19 mm connections: 13 mm (1/2” ): GARDENA Pump Connection Set, Art. No. 1750 15 mm (5/ 8 ” ): GARDENA Tap Connector, Art. No. 902, and
Standard Hose Connector, Art. No. 916
19 mm (3/4” ): GARDENA Pump Connection Set, Art. No. 1752 Best results in delivery capacity are achieved when using 38 mm
(1 1/2) hoses.
7
a b
The universal fitting 7allows you to connect all the hoses listed in the previous table.
1. Cut off nipples of the universal fitting 7, which are not needed, to match the hose connection.
2. Screw the universal fitting
7
onto the pump.
3. Connect the hose to the universal fitting 7.
We recommend that you secure 38 mm (1 1/ 2 ) and 25 mm (1”) hoses additionally with a GARDENA Hose Clip Art. No. 1591.
Only for 13 mm (1/2 ) hose : The universal fitting 7can also be equipped with a GARDENA Regulator Valve Art. No. 977 so that the contents of the out-
let line do not flow back through the pump after pumping. The Regulator Valve can be ordered from GARDENA Service.
4. Operation
To ensure that the pump draws the water out, the water to be drained must be at least 45 mm deep.
The float switch 5turns the pump on automatically when the water level exceeds the cut-in height and the water is pumped out.
The float switch 5turns the pump off again as soon as the water level falls below the cut-out height.
1. Stand the pump on a firm surface – or – use a rope attached to the carrying handle
2
to immerse the
pump in a well or shaft.
During automatic operation, ensure that the float switch
5
can move freely.
2. Plug the power cable 1into a mains socket.
Adjusting the Cut-in and Cut-out Height:
The maximum cut-in height and minimum cut-out height (see
8. Technical Data) can be adjusted.
v Push the cable of the float switch 5into the float switch lock 3.
Do not select a cable length that is too long or short to ensure that the float switch can turn on and off properly.
The shorter the length of cable between the float switch
5
and the float switch lock 3, the lower the cut-in height and the higher the cut-out height.
The pump remains in constant operation because the float switch is bypassed.
1. Stand the pump on a firm surface – or – use a rope attached to the carrying handle
2
to immerse the
pump in a well or shaft.
2. Plug the power cable 1into a mains socket.
3. Fix float switch 5vertically above the pump (with the cable at the bottom).
As long as the float switch is positioned vertically above the pump, the pump will operate regardless of the water level.
The residual water height of approx. 5 mm is only reached during manual operation since the float switch turns off the pump during automatic operation before this water level is reached.
Connecting the hose:
7
6
2
3
5
4
1
7
Automatic operation:
Manual operation:
2
5
1
4
Page 4
15
G
14
G
Flushing the Pump:
Cleaning the suction base and turbine:
5. Cleaning
The pumps are virtually maintenance-free. After having pumped chlorinated swimming pool water or other
liquids leaving residues, the pump should be rinsed with clear water.
Warning! Electric shock !
A Risk of injury due to electric shock.
V Disconnect the pump from the mains before clean-
ing the suction base and turbine.
1. Unscrew the 3 Phillips screws
8
and pull the suction base
6
off the pump.
2. Clean the suction base 6and the turbine 9.
3. Reinstall the suction base 6and screw in the Phillips screws 8.
For safety reasons a damaged turbine
9
can only be ex-
changed by the GARDENA Service Centre.
6. Trouble-Shooting
Problem Probable cause Remedy
Pump is running, Air cannot escape, since v Open pressure line but doesn’t deliver. pressure line is closed. (e.g. kinked pressure pipe).
Air locks in the suction base. v Wait for max. 60 seconds
until the pump deaerates automatically over the vent valve. If necessary, switch off and start it again.
Turbine clogged. v Disconnect plug and clean
turbine (see 5. Cleaning).
When starting the pump, v Submerge pump deeper. water height falls below the min. water level.
Pump doesn’t start or Thermal overload switch has v Disconnect plug and clean suddenly stops during switched the pump off due turbine (see 5. Cleaning). operation. to overheating.
Observe max. media temper­ature of 35 °C.
No power. v Check fuses and electric
connections.
Dirt particles are jammed v Disconnect plug and clean in the suction base. suction base (see 5. Clean-
ing).
Pump runs, but output Suction base is clogged. v Disconnect plug and clean suddenly decreases. suction base (see 5. Clean-
ing).
Attention!
Repairs on electrical parts should only be done by our GARDENA Service Centres.
If you have any problems with your Pump, please contact our Service.
7. Storage
Store the pump away from frost before the first frost sets in.
8. Technical Data
Type 5000 S (Art. No. 1778) Rated power 200 W Max. delivery capacity 5,000 l/ h Max. pressure 0.5 bar Max. delivery height 5 m Max. submersion depth 9 m Flat suction down to approx. 5 mm
Contaminated water with particle size of max. 5 mm
Power cable 10 m H05 RNF Pump connection 38 mm (1 1/2) / 25 mm (1) graduated nipple,
option GARDENA Water hose Plug-in-system
Min. water level for operation 45 mm Weight approx. 4.0 kg Max. media temperature 35 °C
Mains voltage / mains frequency 230 V / 50 Hz
Min.cut-in height 380 mm Min./ max. cut-out height 100 mm / 140 mm
Noise level L
WA
1)
46 dB(A)
1) Measuring method according to EN 60335-1
The cut-in and cut-out height varies.
The residual water depth (draining in the flat position down to approx. 5 mm) is only reached during manual operation (see 4. Operation).
The GARDENA Submersible Pump is manufactured in accordance with the current electrical safety regulations of the Appliance Safety Law (GSG) and inspected by the TÜV (German institution for technical surveillance).
Frost-free storage
9
6 8
Cut-in / Cut-out height
Safety and Approval
Page 5
17
G
16
G
EU Certificate of Conformity
The undersigned GARDENA Kress + Kastner GmbH · Hans-Lorenser-Str. 40 · D-89079 Ulm hereby certifies that, when leaving our factory, the unit indicated below is in accordance with the
harmonised EU guidelines, EU standards of safety and product specific standards. This certificate becomes void if the unit is modified without our approval.
Warranty
Product Liability
Performance characteristics
9. Service
GARDENA guarantees this product for 2 years (from date of purchase). This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults. Under warranty we will either replace the unit or repair it free of charge if the following conditions apply:
The unit must have been handled properly and in keeping with the requirements of the operating instructions.
Neither the purchaser or a non-authorised third party have attempted to repair the unit.
The turbine is a wearing part and is not covered by the guar-antee. This manufacturer’s guarantee does not affect the user’s existing
warranty claims against the dealer/seller.
If you have any problems with your pump, please contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet.
We expressly point out that, in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an authorised specialist. The same applies to spare parts and accessories.
Description of the units: Submersible Pump Types: 5000 S Art. No. : 1778 EU directives: Machinery Directive 98/37/EC
Electromagnetic Compatibility 89/336/ EC Low Voltage Directive 73/23 / EC Directive 93/68/EC
Harmonised European standards: EN 292-1 Ulm, 29.05.2001
EN 292-2 EN 60335-1 EN 60335-2-41
Year of CE marking: 2002 Thomas Heinl
Technical Dept. Manager
m
5
4
3
2
1
0
0 1000 2000 3000 4000 5000
l/h
bar
0.5
0.4
0.3
0.2
0.1
5000 S
Page 6
Deutschland
GARDENA Kress + Kastner GmbH GARDENA Service Hans-Lorenser-Straße 40 D-89079 Ulm Produktfragen: (07 31) 490 - 123 Reparaturen: (07 31) 490 - 290
Argentina
Argensem S.A. Venezuela 1075 (1618) El Talar - Buenos Aires
Australia
NYLEX Corporation Ltd. 25-29 Nepean Highway P.O. Box 68 Mentone, Victoria 3194
Austria
GARDENA Österreich Ges. m.b.H. Stettnerweg 11-15 2100 Korneuburg
Belgium
MARKT (Belgium) NV/SA Sterrebeekstraat 163 1930 Zaventem
Brazil
M. Cassab Av. das Nações Unidas, 20.882 Santo Amaro, CEP 04795-000 São Paulo - S.P.
Bulgaria / България
ДЕНЕКС ООД
Бул. ”Г.М.Димитров” 16 ет.4 София 1797
Canada
GARDENA Canada Ltd. 100, Summerlea Road Brampton, Ontario Canada L6T 4X3
Chile
Antonio Martinic Y CIA. LTDA. Gilberto Fuenzalida 185 Loc. Las Condes - Santiago de Chile
Costa Rica
Compania Exim Euroiberoamericana S.A. 350 Sur del Automercado Los Yoses San Pedro
Cyprus
FARMOKIPIKI LTD P.O. Box 7098 74, Digeni Akrita Ave. 1641 Nicosia
Czech Republic
GARDENA spol. s.r.o.
Шнpskб 20a, и.p. 1153
62700 Brno
Denmark
GARDENA Danmark A/S Naverland 8 2600 Glostrup
Finland
Habitec Oy Martinkyläntie 52 01720 Vantaa
France
GARDENA France Service Après-Vente BP 50080 95948 ROISSY CDG Cedex
Great Britain
GARDENA UK Ltd. 27- 28 Brenkley Way Blezard Business Park Seaton Burn Newcastle upon Tyne NE13 6DS
Greece
Agrokip G. Psomadopoulos & Co. 20, Lykourgou str. Kallithea - Athens
Hungary
GARDENA Magyarország Kft. Késmárk utca 22 1158 Budapest
Iceland
Heimilistaeki hf Saetun 8 P.O. Box 5340 125 Reykjavik
Republic of Ireland
Michael McLoughlin & Sons Hardware Limited Long Mile Road Dublin 12
Italy
GARDENA Italia S.r.l. Via Donizetti 22 20020 Lainate (Mi)
Japan
KAKUDAI Mfg. Co. Ltd. 1-4-4, Itachibori Nishi-ku Osaka 550
Luxembourg
Magasins Jules Neuberg Grand Rue 30 Case Postale No. 12 Luxembourg 2010
Netherlands
GARDENA Nederland B.V. Postbus 50176 1305 AD ALMERE
Neth. Antilles
Jonka Enterprises N.V. Sta. Rosa Weg 196 P.O. Box 8200 Curaçao
New Zealand
NYLEX New Zealand Limited Private Bag 94001 South Auckland Mail Centre 10 Offenhauser Drive East Tamaki, Manukau
Norway
GARDENA Norge A/S Postboks 214 2013 Skjetten
Poland
GARDENA Polska Sp. z o.o. Szymanów 9 d 05-532 Baniocha
Portugal
MARKT (Portugal), Lda. Recta da Granja do Marquês Edif. GARDENA Algueirão 2725-596 Mem Martins
Russia / Россия
АО АМИДА ТТЦ ул. Моcфилмовcкая 66 117330 Моcква
Singapore
Variware Holland Road Shopping Centre 227-A 1st Fl., Unit 29 Holland Avenue Singapore 1027
Slowenia / Croatia
Silk d.o.o. Trgovina Brodišče 15 1236 Trzin
South Africa
GARDENA South Africa (Pty.) Ltd. P.O. Box 11534 Vorna Valley 1686
Spain
ANMI Andreu y Miriam S.A. Calle Pere IV, 111 08018 Barcelona
Sweden
GARDENA Svenska AB Box 9003 20039 Malmö
Switzerland
GARDENA Kress + Kastner AG Bitziberg 1 8184 Bachenbülach
Ukraine / Украина
АОЗТ АЛЬЦЕСТ ул. Гайдара 50 г. Киев 01033
Turkey
Dost Diþ Ticaret Mümessillik A.Þ. Yeþilbaðlar Mah. Baþkent Cad. No. 26 Pendik - Ýstanbul
USA
GARDENA 3085 Shawnee Drive Winchester, VA 22604
1778- 20.960 .01/ 0021
©
GARDENA Kress + Kastner GmbH Postfach 27 47, D -89070 Ulm http: // www.gardena.com
Loading...