Galaxy Aqua 4000, Aqua 4000 si Installation Instructions Manual

IMPORTANT!
This Step-by-Step guide should be given to the customer
after installation and demonstration.
Aqua
44
000000
44
Ii
S
&
Instantaneous Electric Shower
Installation Instructions
Technical Hotline
Telephone: 0844 372 7766 Fax: 0844 372 7767
Email: technical-services@applied-energy.com
9.00 am - 5.00 pm Monday to Friday
SERVICE POLICY
In the event of you needing to contact the Galaxy Technical Hotline, the following procedure should be followed:-
1
If a service call is booked, you or a representative must be present during the Engineers visit.
Before telephoning the Galaxy Technical Hotline you should ensure that you have the model number, power rating, serial number and date of purchase.
The Galaxy Technical Hotline will be able to inform you whether the fault can be rectified by the provision of a replacement part or an on site visit by a Qualified Service Engineer.
If the product is no longer covered by the Guarantee, a charge will be made for the site visit and for any parts supplied.
A charge will be made where a call under the terms of the guarantee has been booked and a failure was not product related, or an engineer arrives and is not able to gain access.
2
3
4
5
01/2011
Aqua
44
000000
6
5
7
4
3
8
9
10
2
1
TEMPERATURE
LOW
COLD
STOP
HIGH
PRESSURE
LOW
AUTO RESET
6
9
0 m
m
339
mm
218 mm
PACK CONTENTS
Shower Unit Showerhead Flexible Hose Slider Rail Tube Slider Rail Brackets Slider Rail Showerhead Holder Soap Dish Screw Pack
IMPORTANT
1. Shower installation must be carried out
by a suitably qualified person and conform with IEE Regulations and National Water Council bylaws.
2. This shower unit is designed to be connected to a 15mm cold water mains supply. Do not connect to a tank supply
unless a suitable booster pump is fitted.
3. To make sure of activating the heating
elements, the shower must be connected to a mains water supply with a minimum running pressure of 100kPa (15 lb/sq in) - (1 Bar) at a minimum flow rate of 8 litres per minute. The maxi­ mum static pressure must be no greater than 1000kPa (150 lb/sq in) - (10 Bar). (Minimum running pressure must be
obtained at 9 litres/minute for 9.5kW and 11 litres/minute for the 10.5kW).
4. The shower unit must not be fitted where it may be exposed to frost, for example in an outdoor shower area. The shower must not be used if
suspected of being frozen. Frost damage is not covered by the
guarantee.
5. Plumbers jointing compound must not be used. In instances of difficult joints use P.T.F.E.
Tape. The use of compound invalidates the guarantee.
6. All plumbing connections must be completed before making the electrical connections.
7. The outlet of your shower acts as a vent and must NOT be connected to any form of tap or fitting not recommended by Applied Energy Products Ltd.
8. Always switch OFF at the isolating switch when not in use.
The following points will help you to understand how your Galaxy shower unit operates.
The flow rate of water passing through the shower unit determines the water temperature. The lower the flow the warmer the water, the higher the flow the cooler the water.
The temperature produced by the shower unit will vary between seasons on any one setting of the temperature control. This is due to variance in the temperature of the water supply, which becomes cooler in winter than summer.
The stabiliser valve maintains an almost constant shower temperature during mains water pressure changes.
If changes in temperature are experienced in normal use, it is likely to be caused by water pressure falling below the minimum level. Falls in water pressure may be due to water being drawn off at other points within the building.
The shower head must be cleaned regularly to remove scale and debris. If the water becomes hot and you are unable to obtain cooler water, check the shower head for blockage.
2
SECTION
GENERAL ADVICE TO SHOWER UNIT USERS
1
SECTION
PACKING CONTENTS