General Information
GAI-Tronics offers the Model 773-001 Outdoor Jack Station which, when used in conjunction wit h a
Model 770-202 or Model 770-204 Portable Page/Party
not desirable to invest in ha ndset st ations f or all possib l e locations . The portable st ation is easily
tr ansported using the atta c hed carrying handle, and t he 25-foot c able provides mobility to the us er.
®
station, is ideal for ex tensive facilities where it is
The ja c k station is wir ed to only one party line, whic h must be dedicated to t he p ortable st ation u sers
because the stat ion does not have a party-line select or swit c h.
Figure 1. Model 773-001 Outdoor Jack Sta tion
GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA
610-777-1374 800-492-1212 Fax : 610-796-5954
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
V
Pub. 42004-204A
Model 773-001 Outdoor Jack Stat ion Page:
2 of 2
Installation
1. Remove the four screws loca ted on the front of t he jack stat ion u nder the hinged door.
2. Remove the two sc rews securing the jack pl ate. Remove the jack pl ate.
3. Remove the conduit plugs on the top a nd bottom of the jack s tat ion.
4. Secure the jac k station to t he condu it, feeding t he cable through the conduit hub.
5. Wire t he jack st ation. Refer to Figu re 2 for wiring details. In single-p arty systems, the orange (s pare)
conduct or wire is the only one not used. In mult i- party systems, tap e b ack the conductors for the part y
lines not linked to the port able stat ion.
6. Secure the jac k plat e u sing the two s c rews saved ear lier.
7. Secure the jac k c over using the two screws saved ear lier.
8. Verify p roper opera tion of the station by plu gging in and us ing a porta ble station.