Gaggenau VL414110 PRODUCT SPECIFICATIONS

VL 414 110
Stainless steel Ventilation unit Comes without blower and AA 490 control knob. (order separately)
Required installation accessories
AA 490 710
one blower (AR 400 inline blower).
For more details on the actual control knob, see page 68.
AD 724 040
Transition to 5" round. Required to connect duct to bottom of VL 414 downdraft or when connecting duct to right / left side of VL 414 downdraft (see adjacent drawing).
AD 724 041
Rectangular adapter piece. Must order AD 724 040 transition to 5" round to vent downwards / left or right and AD 724 041 when venting to left or right side of VL 414 downdraft. No duct connection pieces are included.
Installation accessories
In combination of several Vario cooktops or VL 414 downdraft, connecting strips must be used. Choose respective VA 420 strip from one of the below, depending on type of installation.
VA 420 010
Connection strip for surface-mount installation without appliance cover.
VA 420 011
Connection strip for surface-mount installation with appliance cover.
VA 420 000
Connection strip for flush installation without appliance cover.
VA 420 001
Connection strip for flush installation with appliance cover.
VA 450 110
Stainless steel adjustment strip,
width 4 ⁵⁄₁₆". Necessary accessory
in a combination of Vario cooktops with at least one appliance cover adjacent to VL 414 downdraft.
AS 070 000
Connection piece as extension required for installation with VK 414 steamer or VF 414 fryer.
Optional accessories
AA 414 010
Air deflector for combination with gas cooktops.
Vario 400 series downdraft ventilation
VL 414
– Highly efficient ventilation
system at cooktop level.
– Up to 4 ventilation units can
be connected to a single AR 400 inline blower, operated by one AA 490 control knob.
– Flexible power distribution,
precise extraction of cooking vapors.
Precision crafting of ⅛-inch
stainless steel.
– For surface-mount installation
with a visible edge or for flush installation.
– Can be perfectly combined with
other Vario 400 series products
– Minimal planning and easy
installation for air recirculation.
Output
Maximum air output in combination with AR inline blower / remote blower or recirculation blower. For CFM information, refer to blower overview on page 155. Noise level depends on the built-in situation.
Features
Ventilation channels manually rotate to open air channel. Closing element made of stainless steel, dishwasher-safe. Metal grease filter with grease drip tray, dishwasher-safe. Sensor-controlled operation of the AR blower if at least one VL 414 downdraft unit is open.
Planning notes
Depending on the type of installation — surface-/ or flush-mounted, with or without cover — the specific location of the control knob positions may vary. When using the appliance cover VA 440 or adjustment strip VA 450 additional space for cut-out depth needs to be considered. In a combination of Vario cooktops with at least one appliance cover, the adjustment strip VA 450 is required. In a combination of several Vario 400 series cooktops, connection strips must be used. Depending on the type of installation — surface-/ or flush-mounted, with or without cover — the respective VA 420 connecting strip must be used. For flush installation the edge height in the cut-out needs to be at least ½" and for surface-mount ⅜" . Ensure a continuous cut surface of 90°. The weight capacity and stability, especially in case of thin counter­tops, must be supported using suitable substructures. Take the appliance weight and additional loads into account. Flush installation is possible in countertops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the edges must be observed. For other materials, please consult with your countertop manufacturer. The groove must be continuous and even, so that uniform placing of the appliance on the gasket is ensured. Do not use discontinuous lining.
The joint width may vary due to size tolerances of the combinations and of the countertop cut-out.
Please read additional planning notes on pages 72 – 79.
If installing several Vario products in individual cut-outs allow for a minimum distance of 2" between the cooktops. Air extraction operation in combination with remote AR 400/401 remote / inline blowers or recirculation mode with AR 413. Please refer to page 144 for recommended downdraft ventilation configurations of blower units and needed ducting elements. Maximum cooktop width between two VL downdraft units is 24". If used next to gas cooktops, the air deflector AA 414 is recommended to ensure maximum performance of the cooktop. No duct connection pieces are included, they must be ordered separately. Either AD 724 040 transition to 5" round duct to connect to bottom / left / right side of VL and AD 724 041 transition if connecting duct to left or right side of VL downdraft. When connecting 2 VL downdrafts, 2x 5" round ducts are required to connect to one of the AR blowers. Note: when connecting 2x VL downdrafts with AR 401 740 remote blower, a Y-adaptor is required (can be purchased at local hardware store). When connecting 3 or 4x VL downdrafts, only AR 400 740 inline blower can be used. Please ensure when installing the exhaust air ducting that no sharp bendings are caused and that the cross-section of the ducting is not constricted in any way. This can have an impact on the blower performance. Appliance can be snapped into the countertop from above. Additional fixing by clamps that are accessible from the top, clamping range from 1 ³⁄₁₆" to 1 ¹ ⁵⁄₁₆".
Rating
60 Hz Plan for a 6.6' connection cable between VL 414 downdraft and AA 490 control knob.
66 Vario cooktops
min.
115/16"
(50)
min. 16/16" (
35)
min. 42/16" (105)
max. 66/16" (162)
Cable access
right-hand side
Max. 4 VL 414 can
be connected to
AA 490 710 control knob
dia. 1
6
/
16
" ( 35)
dia. 2
2
/16"
(60)
Length 78
12
/16" (
2000)
5"
(∅
125)
5"
(∅
125)
round duct
left/right
round duct
45/16"
(110)
36/16" (
85)
58/16" (
140)
315/16"
(100)
24/16" (
57)
34/16" (
82)
45/16" (109)
23/16"
(56)
21/16"
(53)
39/16"
±1
/16
" (90±2)
2
/16" (
3)
612/16" (
171)
208/16" (
520)
*211/16" (
535)
AA 490 710
196/16"
±1
/16
" (492±2)
204/16"
+1/
16
" (515+2)
min.
115/16"
(50)
min. 16/16" (35)
min. 45/16" (109)
max. 69/16" (166)
Cable access
right-hand side
dia. 16/16" (
35)
dia. 22/16"
(60)
Max. 4 VL 414
can be connected to
AA 490 710 control knob
Length 78
12
/16" (
2000)
5"
(∅
125)
5"
(∅
125)
round duct
left/right
round duct
R 3/16"
(R 5)
R 1/8" (R 3)
1
/8"
(3.5
-0.5
)
45/16"
(110)
36/16" (
85)
58/16" (
140)
315/16"
(100)
24/16" (
57)
34/16" (
82)
45/16" (109)
23/16"
(56)
21/16"
(53)
49/16"
+1
/16
"
(116+2)
39/16"
±1
/16
"
(90±2)
614/16" (
174)
208/16" (520)
*211/16" (535)
AA 490 710
196/16"
±1
/16
"
(492±2)
204/16"
+1/
16
"
(515+2)
2011/16"
+1
/16
"
(526+2)
215/16"
+1/
16
"
(541+2)
90°
Surface-mount Installation Flush-mount Installation
VL 414 with AD 724 040/041
dia.
4
15
/
16
"
(125)
36/16" (85)
58/16"
(140)
55/16" (135)
View from above
R 3/16"
(R 5)
R 1/8"
(R 3)
228/16"+1/16" (562+2)
*215/16"+1/16" (541+2)
196/16"±1/16" (492±2)
*204/16"+1/16" (515+2)
39/16"±1/16" (
90±2)
49/16"+1/16" (
116+2)
Cross-section
fill with
silicone
2/16
" (
3.5
-0.5
)
196/16"±1/16"
(492±2)
2011/16"+1/16"
(526+2)
11/16
"
(17)11/16"
(17)
2/16"+1/16
"
(3+1)
2/16"+1/16
"
(3+1)
208/16"
(520)
When installing with appliance cover or adjustment strip, pay attention to
the deeper cut-out and the front and rear groove width.
fill with silicone
Longitudinal section
2/16
" (3.5
-0.5
)
39/16"
±1/16
"
(90±2)
49/16"
+1/
16
"
(116+2)
45/16"
(110)
8/16
" (13)8/16" (13)
2/16"+1/
16
"
(3+1)
2/16"+1/
16
"
(3+1)
151/16" (382)
151/16" (382)
1410/16" (372) 26/16" (60)
29/16" (65)
AS 070 000
AD 724 040+ AD 724 041
AD 724 040+ AD 724 041
* With adjustment strip. See separate planning notes on page 78–79.
- positioning of control knob
- configuration for flexible power distribution.
Round duct connection, bottom ∅ 5" with AD 724 040 Round duct connection left/right ∅ 5" with AD 724 040 + AD 724 041
AD 724 040+ AD 724 041
* With adjustment strip. See separate planning notes on page 78–79.
- positioning of control knob
- configuration for flexible power distribution.
Round duct connection, bottom ∅ 5" with AD 724 040 Round duct connection left/right ∅ 5" with AD 724 040 + AD 724 041
AD 724 040+ AD 724 041
VL 414 with AD 724 040/041
AD 724 041 rectangular adaptor pieces
AS 070 000 connection piece for extension
AD 724 040 transition to 5” round
View from above
* with adjustment strip.
Longitudinal section
Numbers indicated inside parenthesis ( ) = mm
Cross-section
Vario cooktops 67
Loading...