Gaggenau AI402720 Operating/installations instructions

AI 400720
Gaggenau
en Operating and installation instructions fr Mode d’emploi et notice de montage es Instrucciones de uso y de montaje
30’’
30’’
3
Table of contents
Operating insructions
General Information 4
Information on protection of the environment 4 Before using the appliance for the first time 4
Safety Instructions 5
Intended use 5 Technical safety 6 Special information for gas cookers 7 Corect installation 8
Operating modes 9
Exhaust-air mode 9 Circulating-air mode 9
Operating procedure 10
Cleaning and care 12
Removing and installing the grease filters 13
Removing and installing the metal-mesh grease filters 13 Installing and removing the activated carbon filters 13
Changing the bulbs 14
Installation instructions
Installation instructions 15
Connecting pipes 15 Electrical Connections 16
Installation 17
Installation preparations 17 Attachment 18 Installing the flue ducts 19
5
READ AND SAVE THESE INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF A RANGE
TOP GREASE FIRE. a) Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high
heat.
c) Clean ventilating fans frequently.
Grease should not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use
cookware appropriate for the size of the surface element.
Do not flambé under the extractor hood or work with a naked flame. When switched on, the extractor hood draws flames into the filter.
In the event that personal clothing or hair catches fire, drop and roll immediately to extinguish flames.
Smother flames from food fires other than grease fires with baking soda.
Never use water on cooking fires. CAUTION: Grease left on filters can remelt and
move into the vent. Always have a working smoke detector near the
kitchen. WARNING – TO REDUCE THE RISK OF INJURY
TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a closefitting lid,
cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN. You may be
burned.
c) DO NOT USE WATER, including wet dish
cloths or towels. A violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you already know how to operate it.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit.
WARNING – Whenever possible, do not operate blower during a cooktop fire. However, do not reach through fire to turn off blower.
When children become old enough to use the appliance, it is the legal responsibility of the parents or legal guardians to ensure that they are instructed in safe practices by qualified persons.
Do not allow children to use this appliance unless closely supervised by an adult.
Children and pets should not be left alone or unattended in the area where the appliance is in use. They should never be allowed to play in its vicinity, whether or not the appliance is in use.
CAUTION – Items of interest to children should not be stored in an appliance, in cabinets above an appliance or on the backsplash. Children climbing on an appliance to reach items could be seriously injured.
Do not allow anyone to climb, stand, lean, sit, or hang on any part of an appliance, especially a door, warming drawer, or storage drawer. This can damage the appliance, and the unit may tip over, potentially causing severe injury.
WARNING – Be sure the entire appliance (including the grease filters and light bulbs, if applicable) has cooled and grease has solified before attempting to clean any part of the appliance.
Have the installer show you the location of the circuit breaker or fuse. Mark it for easy reference.
CAUTION – Turn power off at breaker before removing a damaged bulb. Do not touch the bulbs immediately after use.
The bulbs will remain hot for several minutes.
WARNING – Make sure the appliance and lights are cool and power to the appliance has been turned off before replacing the light bulb(s). Failure to do so could result in electrical shock or burns.
The lenses (if equipped) must be in place when using the appliance.
The lenses (if equipped) serve to protect the light bulb from breaking.
The lenses (if equipped) are made of glass. Handle carefully to avoid breaking.
Broken glass can cause an injury.
$
Important Safety Instructions – Use and Care
7
Safe operation is possible provided the low pressure in the installation room of the heating appliance does not exceed 4Pa (0.04mbar). This can be achieved if the combustion air can flow through non-closable openings, e.g. in doors, windows, in conjunction with air intake/exhaust air wall boxes or by other technical measures.
Adequate intake air must therefore always be provided.
An intake/exhaust air wall box alone does not ensure compliance with the limit value.
Note: When making your evaluation, always consider the entire ventilation system in the home. Include the advice of a competent heating engineer when making your evaluation.
If the extractor hood is used in circulating air mode only, it can be operated without any restrictions.
Special information for gas cookers
When installing the extractor hood above gas hobs, observe the appropriate national statutory regulations.
Observe the currently valid installation regulations and instructions of the gas appliance manufacturer.
During installation, ensure that only one side of the extractor hood is situated directly next to a high-sided unit or a wall. Otherwise, there is a risk of heat build-up. The gap between the extractor hood and the wall or high-sided unit must be at least 1 5/16”.
RISK OF BURNS
Do not operate more than 2 gas cooking areas simultaneously over a period of max. 15 minutes at maximum thermal load. Due to the effect of the heat there is a risk of burns if the surfaces of the housing are touched!
Note that one large burner of more than 5 kW (Wok) is equivalent to the power of 2 gas burners.
The extractor hood may be damaged by the intense heat.
Never operate a gas cooking area without a cooking utensil on it. Regulate the flame in such a way that it does not project over the cooking utensil.
9
The extractor hood can be used in exhaust air and circulating air mode. The standard setting is exhaust air mode.
Exhaust-air mode
Installation accessories for exhaust air mode
Stainless steel-design ventilation duct:
AD 010-016 for ceiling heights of 87 13/16”-94 7/8” AD 010-026 for ceiling heights of 94 7/8”-107 1/2” AD 010-036 for ceiling heights of 107
1
/2”-117 11/16”.
The air which is drawn in is cleaned by the grease filters and conveyed to the exterior by a pipe system.
Appliance dimensions Exhaust air
Circulating-air mode
Installation accessories for circulating air mode
Stainless steel-design ventilation duct:
AD 010-126 for ceiling heights of 94 7/8”-107 1/2” AD 010-136 for ceiling heights of 107 1/2”-117 11/16”.
The air which is drawn in is cleaned by the grease filters and an activated carbon filter and conveyed back into the kitchen.
An activated carbon filter must be installed to bind odours in circulating-air mode (see ”Removing and installing the grease filters”).
The complete installation set as well as the replacement filters are available from specialist outlets, customer service or the Online Shop. The accessory number can be found at the end of the operating instructions.
The socket must be attached at least 6
11
/16” below
the ceiling.
Appliance dimensions Circulating air
Operating modes
min. 2213/16’’ max. 55
11
/16’’
min. 6
1
/8’’
min. 2213/16’’ max. 59
13
/16’’
min. 1
3
/8’’
11
Special functions
Intensive time:
You can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the Int key and the 1, 2 or 3 key and you can store this setting. When delivered, the appliance is set to five minutes, i.e. the combination of the Int key and the key 2.
Fan follow-on:
Delayed shut-off is possible at any level. First press the required key 1, 2, 3 or Int and then press the key. The delayed shut-off time for all levels is ten minu-tes. After these ten minutes, the ventilation switches off, but the lighting stays on.
Interval ventilation:
Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour. You can activate this function by simultaneously pressing the 0 key and, depending on the required extraction capacity, the 1, 2 or 3 key.
This mode of operation is indicated by alternating illumination of the key together with the corresponding fan level indicator.
You can switch off interval ventilation by pressing the 0 key.
Lighting:
Briefly press the button to switch the light on and off.
The light can be switched on at any time, even though the fan is switched off.
Adjusting the brightness:
Hold down the button until the desired brightness is obtained.
Saturation indicator: F
The grease filter saturation display F flashes after an operating time of 30 hours to indicate that you should clean the grease filter. The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not started to flash.
To cancel the display, press the F button.
13
Cleaning the glass plates
Apply commercially available window cleaning agent with a soft, moist cloth.
To facilitate cleaning, you can detach the glass plates as follows: Detach the grease filters. In the extractor hood, you will find three openings on the upper side through which you can lift the glass plates singly with a blunt object (e.g. handle of a wooden spoon) to detach them with greater ease.
If they are extremely soiled, the glass plates can be cleaned in a dishwasher at a maximum temperature of 131 °F.
Note: when putting the glass plates back in place, make sure that you do not scratch the chimney. Replace the glass plates with the printed side facing down. Position the glass plates at the chimney side first.
RISK OF INJURY
Before removing and installing the grease filters, always follow the instructions and warnings in the chapter entitled ”Safety instructions”!
Removing and installing the metal-mesh grease filters
1 Open the lock and fold down the grease filters.
In doing so, hold the underside of the grease filters with your other hand.
(for appliances with edge extraction)
2 Clean the grease filters.
3 Reinsert the cleaned grease filters.
Removing and installing the grease filter
15
Installation instructions
Prior to installation, always follow the instructions and warnings in the chapter entitled ”Safety instructions”!
Exhaust-air mode
The exhaust air is conveyed upwards via a ventilation shaft or directly through the outer wall to the exterior.
Note: The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heating appliances.
Before conveying the exhaust air into a non­functioning smoke or exhaust gas flue, obtain the consent of the appropriate heating engineer.
Discharge exhaust air in accordance with the official and statutory regulations (e.g. regional building laws).
If the exhaust air is conveyed through the outer wall, a telescopic wall box should be used.
To ensure optimum performance, the extractor hood requires:
a short, straight exhaust air pipe and
the largest possible pipe diameter.
If pipe bends cannot be avoided, ensure the largest possible radii.
Note: If long, rough exhaust air pipes, a lot of pipe bends or pipe diameters less than 5
7
/8” are used, the air capacity will be less than optimum and there will be an increase in noise.
Use only pipes or hoses made of non­combustible material for installation of the exhaust air duct.
The manufacturer of the extractor hoods is not responsible for complaints which can be attributed to planning and design of the pipework.
Connecting pipes
The diameter of the exhaust air pipes should not be less than 5 7/8”.
Round pipes:
We recommend an inner diameter of 5
7
/8”,
however at least 4
3
/4”.
Flat ducts must have the same inner cross­section as round pipes. There should be no sharp bends. Ø 5
7
/8” approx. 177 cm
2
Ø 4 3/4” approx. 17 3/4” square inch
If pipe diameters differ:
Use sealing strips.
Connection of 5 7/8” ø exhaust air pipe (recommended size)
Attach exhaust air pipe directly to the air-pipe connector and seal appropriately. If using an aluminium pipe, smooth the connection area beforehand.
Connection of 4
3
/4” ø exhaust air pipe
Attach reducing connector directly to the air-pipe connector.
Attach exhaust air pipe to the reducing connector.
Seal both joints appropriately.
17
Installation
The extractor hood is designed for installation on
the kitchen ceiling or on a rigid suspended ceiling.
During installation, optional accessories may also require fitting.
Observe the minimum distance between hob and extractor hood (see ”Safety instructions”)!
Avoid damaging the sensitive surfaces!
Preparing the ceiling
RISK OF INJURY,
DAMAGE TO PROPERTY
Before drilling the holes for the designated installation location, check for concealed electrical cables and other lines.
The ceiling must be level and horizontal.
The enclosed screws and wall plugs are suitable for concrete and natural stone. Use the appropriate fasteners for other ceiling structures. Ensure that the ceiling has adequate load bearing capacity.
Ensure that the depth of the drilled holes corresponds with the length of the screws.
Ensure that the wall plugs are secure.
Max. weight: 110 lbs.
Design subject to modification in line with technical development.
Note: At least one screw for the mounting must be installed through a stud.
Note:
the extractor hood is to be installed to a kitchen ceiling or suspended ceiling. Ensure that the ceiling is capable of providing a firm hold for a maximum weight of hood and accessories of 50 kg / 110 lbs.
Before marking the securing holes, make sure that no electricity wires or water pipes or other wires/ pipes are laid at the drilling points in the ceiling.
Before installation check the enclosed wall plugs and screws are suitable for your ceiling. If necessary use special wall plugs.
Installation of the extractor hood:
1 Using the drilling template mark the position of
the screws on the ceiling.
2 Drill 4 holes Ø
5
/16” for the wall plugs. Push the
plugs flush with the ceiling.
3 Turn two screws to a 3/8” gap. Both screws are
placed in a position, in which at a later stage of the installation the key-holes of the supporting frame are found (namely back left and front right from the control panel of the hood).
135/8’’
7
7
/8’’
Loading...