Fulgor Milano F7IT36S1 User Manual

36” Induction Cooktop 700 SERIES
lb /
inch
Kg /
mm
W
H
40"1/2
7"1/4
1030
185
Weight & Dimensions
CUTOUT DIMENSION
LENGTH OF CUT
A
SEE NOTE
1-1/2” (3.8CM)
MIN CLEARANCE
R
CUTOUT REQUIREMENTS
NOTE R
Insure smooth edges and prevent corner cracking. Recommend 1/4“or 3/8“diameter drill in each.
* NOTE 24” (61 cm) min. clearance if bottom of wood or metal cabinets is protected by not less than 1/4“ (0.6
LENGTH OF CUT
B
FROM EDGE OF CUTOUT TO FRONT EDGE OF COUNTERTOP 2-1/2” (6.5 cm)
G
C
F
Ltr. CUTOUT DIMENSION inch cm
A Cutout Width
B Cutout Depth
C Opening between cabinets
D
E
F
G Depth of unprotected overhead cabinets
WALL COVERING CABINETS, AND COUNTERTOP MUST WITHSTAND HEAT UP TO 93° C (200° F)
36” 3/16
(919 mm)
Height from countertop to nearest cabinet on either side of unit
Clearance from countertop to unprotected overhead surface
Clearance from cutout to side wall on the left and right of the unit
PACKAGING
GROSS WEIGHT
DIMENSION
34-5/8” +/- 1/16”
+/- 1/16”
Min 36” min Min 91.4
19-7/16”
Min 18” Min 45.7
Min 30” Min 76.2
Min 2” Min 5
Min 13” Min 33
51 lb 22.9 Kg
D
23"1/2
21” 3/16
(538 mm)
87,9
+/- 0.1
49,4
+/- 0.1
598
E
D
covered with no less than No. 28 MSG sheet steel 0.015” (0.04 cm) stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper. 30”(76.2 cm) min. clearance between top of cooking platform and bottom of unprotected wood or metal cabinet.
1/4”
(6mm)
2” 5/8
(66 mm)
1” 1/16
(27 mm)
36” Induction Cooktop 700 SERIES
25” (635mm)
min
19 7/16” (494mm)
2 1/2”
(64mm)
3 ”
(76mm)
2 1/2”
(65mm)
1 5/8”
(40mm)
max
1/4”
(6mm)
min
4”
(101mm)
min
4 3/4”
(120 mm)
36”
(915mm)
27 3/4”
(705mm)
1 1/2”
(38 mm)
min
24” (610mm)
min
15 3/4”
(400mm)
5”
(127mm)
min
*1/4”
(6mm)
min
Weight & Dimensions
Cooktop Installation
Important Preparation Suggestions
1. Chamfer all exposed edges of decorative laminate to
prevent damage from chipping.
2. Radius corners of cutout and file to ensure smooth edges
and prevent corner cracking. Recommend 1/4” or 3/8”
diameter drill to start cut at each corner.
* The ventilation opening is to extend the full length of the cooktop cutout.
3. Rough edges, inside corners which have not been rounded
and forced fits can contribute to cracking of the countertop
laminate.
Cooktop Installation Over a Single Oven
Use the countertop opening dimensions that are given with
these Instructions.
Check the cooktop base for an approved installation label.
Verify approved oven model numbers that can be installed
with your cooktop model number.
* The ventilation opening is to extend the full length of the cooktop cutout.
*1/4”
(6mm)
min
1/4”
(6mm)
2 1/2”
(64mm)
25” (635mm)
min
19 7/16” (494mm)
min
2 1/2”
(65mm)
The cooktop may be installed over a single oven.
The cooktop should be centred over the oven.
Both the cooktop and the oven must be installed according
3”
(76mm)
to each specific installation instruction.
1 5/8”
(40mm)
max
27 1/4”
(692mm)
36”
(915mm)
4 3/4”
(120 mm)
1 1/2”
(38 mm)
min
4”
(101mm)
min
24” (610mm)
min
Loading...