Fujitsu VFY:R2534SC050IN User Manual

Operating Manual - English
FUJITSU Server PRIMERGY RX2530 M4
Operating Manual
July 2017
CommentsSuggestionsCorrections
The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs.
Feel free to send us your comments by e-mail to
manuals@ts.fujitsu.com.
Certified documentation according to DIN EN ISO 9001:2008
To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2008.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademarks
Copyright 2017 FUJITSU LIMITED
All rights reserved. Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.
– The contents of this manual may be revised without prior notice.
– Fujitsu assumes no liability for damages to third party copyrights or other rights arising from
the use of any information in this manual.
– No part of this manual may be reproduced in any form without the prior written permission
of Fujitsu.
Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries.
Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.
Before reading this manual
For your safety
This manual contains important information for safely and correctly using this product.
Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product.
Radio interference
This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A
Aluminum electrolytic capacitors
The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke.
As a guideline, in a normal office environment (25°C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period.
High safety use
This product has been designed and manufactured to be used in commercial and/or industrial areas as a server.
When used as visual display workplace, it must not be placed in the direct field of view to avoid incommoding reflections (applies only to TX server systems).
The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured.
RX2530 M4
Operating Manual
These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.
Measures against momentary voltage drop
This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended.
(This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.)
Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan
Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law.
Harmonic Current Standards
This product conforms to harmonic current standard JIS C 61000-3-2.
Only for Japan: About SATA HDDs
The SATA version of this server supports HDDs with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of HDD used.
Please refer to the following internet address for further information on the usage and operation conditions of each available type of HDD:
http://jp.fujitsu.com/platform/server/primergy/harddisk/
Operating Manual
RX2530 M4

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.1 Concept and target groups for this manual . . . . . . . . . . 9
1.2 Documentation overview . . . . . . . . . . . . . . . . . . . 10
1.3 Notational conventions . . . . . . . . . . . . . . . . . . . . 11
2 Functional overview . . . . . . . . . . . . . . . . . . . . . . 13
2.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.2 Server specification . . . . . . . . . . . . . . . . . . . . . . 22
3 Installation steps, overview . . . . . . . . . . . . . . . . . . 31
4 Important information . . . . . . . . . . . . . . . . . . . . . 33
4.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 33
4.2 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.3 FCC Class A Compliance Statement . . . . . . . . . . . . . 42
4.4 Environmental protection . . . . . . . . . . . . . . . . . . . 43
5 Hardware installation . . . . . . . . . . . . . . . . . . . . . . 45
5.1 Unpacking the server . . . . . . . . . . . . . . . . . . . . . 46
5.2 Installing/removing the server in/from the rack . . . . . . . 47
5.3 Connecting devices to the server . . . . . . . . . . . . . . . 49
5.4 Connecting the server to the mains . . . . . . . . . . . . . . 52
5.4.1 Connecting the server to the direct current (optional DC PSU) . 53
5.4.2 Using the cable clamps (AC PSU) . . . . . . . . . . . . . . . . 54
5.5 Notes on connecting/disconnecting cables . . . . . . . . . 55
RX2530 M4
Operating Manual
Contents
6 Starting up and operation . . . . . . . . . . . . . . . . . . . . 57
6.1 Controls and indicators . . . . . . . . . . . . . . . . . . . . . 57
6.1.1 Server front . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
6.1.1.1 Controls on the front panel . . . . . . . . . . . . . . . . . . 57
6.1.1.2 Indicators on the front panel . . . . . . . . . . . . . . . . . . 59
6.1.1.3 Indicators on the accessible drives/components . . . . . . . 62
6.1.2 Server rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
6.1.2.1 Indicators on the I/O panel . . . . . . . . . . . . . . . . . . 64
6.1.2.2 Indicator on PSU (slide-in unit) . . . . . . . . . . . . . . . . 67
6.1.2.3 Indicator on Fujitsu battery unit (FJBU) . . . . . . . . . . . . 68
6.1.3 Indicators of the hot-plug system fans . . . . . . . . . . . . . . 68
6.2 ID card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
6.3 Switching the server on and off . . . . . . . . . . . . . . . . 70
6.4 Configuring the server . . . . . . . . . . . . . . . . . . . . . 73
6.4.1 Configuring the onboard SATA controller . . . . . . . . . . . . . 73
6.4.2 Configuring the SAS/SATA RAID controller . . . . . . . . . . . . 74
6.4.3 Configuring the server and installing the operating system
with the ServerView Installation Manager . . . . . . . . . . . . . 75
6.4.4 Configuring the server and installing the operating system
without the ServerView Installation Manager . . . . . . . . . . . 76
6.5 Cleaning the server . . . . . . . . . . . . . . . . . . . . . . . 77
7 Property and data protection . . . . . . . . . . . . . . . . . . 79
7.1 BIOS Setup security functions . . . . . . . . . . . . . . . . . 79
8 Troubleshooting and tips . . . . . . . . . . . . . . . . . . . . 81
8.1 Power-on indicator remains unlit . . . . . . . . . . . . . . . . 81
8.2 Server switches itself off . . . . . . . . . . . . . . . . . . . . 82
8.3 Screen remains blank . . . . . . . . . . . . . . . . . . . . . . 82
8.4 Flickering stripes on monitor screen . . . . . . . . . . . . . 83
8.5 No screen display or display drifts . . . . . . . . . . . . . . . 83
8.6 Incorrect date and time . . . . . . . . . . . . . . . . . . . . . 84
8.7 System will not boot . . . . . . . . . . . . . . . . . . . . . . . 84
Operating Manual
RX2530 M4
Contents
8.8 Drives reported as “dead” when starting system . . . . . . 84
8.9 Added drive reported as defective . . . . . . . . . . . . . . 85
8.10 Error message on screen . . . . . . . . . . . . . . . . . . . 85
8.11 Expansion cards or onboard devices not recognized . . . . 85
8.12 Temperature warning . . . . . . . . . . . . . . . . . . . . . . 86
8.13 No effect of keyboard or mouse . . . . . . . . . . . . . . . . 86
8.14 Optical drive cannot read data . . . . . . . . . . . . . . . . 86
RX2530 M4
Operating Manual
Contents
Operating Manual
RX2530 M4

1 Introduction

The FUJITSU Server PRIMERGY RX2530 M4 is a rack server that provides high performance, expandability and energy efficiency in 1U space saving housing. The PRIMERGY RX2530 M4 is ideal for virtualization, scale-out scenarios, and small databases as well as for high performance computing thanks to the high performance of the new Intel to 28 cores, optionally with embedded FPGA-functionality and the latest DDR4 memory technology. Moreover, the RX2530 M4 delivers a great expandability, by supporting up to 3,072 GB of main memory and is future-proof with M.2 device support and the latest iRMC S5 for server management of the next generation. NV-DIMMs will be supported from mid-2018 on. Up to 10 hard disk drives (HDDs) and optionally up to four high-speed PCIe Solid State Drives (SSDs) offer a flexible storage configuration option. OCP 2.0 technology is onboard to ensure future requirements are met and budgets are saved. The limited space of a 1U chassis offers highly efficient power supply units, their redundancy on demand and the optional Advanced Thermal Design, will result in lower operational costs.

1.1 Concept and target groups for this manual

This operating manual describes how to install, set up and operate your server.
This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. It contains all the information you need to put your PRIMERGY RX2530 M4 into operation.
®
Xeon® P-family CPUs with up
To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system.
RX2530 M4
Operating Manual 9
Introduction

1.2 Documentation overview

More information on your PRIMERGY RX2530 M4 can be found in the following documents:
– "Quick Start Hardware - FUJITSU Server PRIMERGY RX2530 M4"
– "ServerView Quick Start Guide"
– "Safety Notes and Regulations" manual
" 安全上のご注意 " for Japan
– "Warranty" manual
" 保証書 " for Japan
– "ServerView Suite Local Service Concept - LSC" manual
– "Returning used devices" manual and "Service Desk" leaflet
" サポート&サービス " for Japan
– "FUJITSU Server PRIMERGY RX2530 M4 Upgrade and Maintenance
Manual"
– "D3383 BIOS Setup Utility for FUJITSU Server PRIMERGY RX2530 M4
Reference Manual"
– "iRMC S5 - Concepts and Interfaces" user guide
– "iRMC S5 - Configuration and Maintenance" user guide
– "iRMC S5 - Web Interface" user guide
– "ServerView embedded Lifecycle Management (eLCM)" User Guide
– "Integrated RAID for SAS User Guide"
– "LSI MegaRAID - SAS Software User Guide"
– "Modular RAID Controller / Modular SAS HBA Installation Guide"
10 Operating Manual
RX2530 M4
Introduction
I
All documentation on PRIMERGY hardware and ServerView software is available online from the Fujitsu manuals server at:
http://manuals.ts.fujitsu.com
For Japan:
http://www.fujitsu.com/jp/products/computing/servers/primergy/manual/
The complete PRIMERGY documentation set can also be downloaded as a DVD ISO image at:
ftp://ftp.ts.fujitsu.com/images/serverview/manuals
For Japan:
http://www.fujitsu.com/jp/products/computing/servers/primergy/downloads/
Further sources of information:
– ServerView Suite Glossary – Manual for the monitor – Documentation for the boards and drives – Operating system documentation – Information files in your operating system

1.3 Notational conventions

The following notational conventions are used in this manual:
Text in italics indicates commands or menu items.
"Quotation marks" indicate names of chapters and terms that are being
emphasized.
Ê describes activities that must be performed in the order
shown.
V
CAUTION! pay particular attention to texts marked with this symbol.
Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.
I
RX2530 M4
indicates additional information, notes and tips.
Operating Manual 11
12 Operating Manual
Introduction
RX2530 M4

2 Functional overview

This section provides information on the features and technical data of the PRIMERGY RX2530 M4 server.

2.1 Features

Intel® Xeon® P-family CPUs
The server can be equipped with up to two Intel speed data processing.
Customer Self Service (CSS)
The PRIMERGY Customer Self Service (CSS) concept enables you to identify and replace the affected component yourself in the case of certain error scenarios.
In the CSS concept, you can replace the following components yourself in the event of an error:
– Hot-plug HDD/SSD modules
– Hot-plug PSUs
– Memory modules (not allowed for Japan)
®
Xeon® P-family CPUs for high-
– System fans
– Expansion cards (not allowed for Japan)
For information on replacing these components, see the "FUJITSU Server PRIMERGY RX2530 M4 Upgrade and Maintenance Manual".
CSS indicators on the control panel and on the rear of the PRIMERGY server provide you with information if a CSS event arises.
In addition, CSS errors are displayed in the ServerView Operations Manager, the server management software from Fujitsu.
In the event of errors, the ServerView Operations Manager refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question. (This feature is not available for Japan.)
RX2530 M4
Operating Manual 13
Functional overview
I
Further information on the CSS concept is provided in the "PRIMERGY ServerView Suite Local Service Concept - LSC" manual on the Fujitsu manuals server.
For the latest information on optional products provided for the RX2530 M4 see the configurator of the server:
http://ts.fujitsu.com/products/standard_servers/index.html
For Japan:
http://www.fujitsu.com/jp/products/computing/servers/primergy/
System board
The features of the system board are described in the "FUJITSU Server PRIMERGY RX2530 M4 Upgrade and Maintenance Manual", the setup possibilities are described in the "D3383 BIOS Setup Utility for FUJITSU Server PRIMERGY RX2530 M4 Reference Manual".
Trusted Platform Module (TPM)
A Trusted Platform Module (TPM) for safer storage of keys can be implemented as an option. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption).
The TPM is activated via the BIOS system (for more information, refer to the “D3383 BIOS Setup Utility for FUJITSU Server PRIMERGY RX2530 M4 Reference Manual").
V
CAUTION!
– When using the TPM, note the program descriptions provided by the
third party manufacturers.
– You must also create a backup of the TPM content. To do this, follow
the third party manufacturer's instructions. Without this backup, if the TPM or the system board is faulty you will not be able to access your data.
– If a failure occurs, please inform your service about the TPM
activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content.
14 Operating Manual
RX2530 M4
Functional overview
Slots for expansion cards
The server can be flexibly expanded via four slots (1x PCIe Gen3 x8 and 3x PCIe Gen3 x16). A second CPU is required for slot 4.
The FBU for the 3.5" base-unit variant occupies one additional PCIe slot. Depending on the installed RAID controller, for the 3.5" base-unit variant slot 2 or slot 4 is for FBU option.
One horizontal chassis slot is occupied by the OCP module.
HDDs/SSDs
Depending on the chassis the server can be equipped with 4x 3.5-inch HDD modules (with 1x ODD), 4x 2.5-inch HDD/SSD 8x 2.5-inch HDD/SSD
modules
(without ODD).
modules
(with 1x ODD) or 10x 2.5-inch HDD/SSD
modules
(with 1x ODD),
Each HDD/SSD module can accommodate a SAS/SATA HDD or a SATA SSD with a maximum height of 1 inch. The HDD/SSD module is connected to the SAS/SATA backplane wirelessly. This allows HDD/SSD modules to be plugged in or pulled out easily.
To control SAS HDDs, an additional RAID controller must be installed. To control PCIe SSD modules an additional PCIe controller must be installed.
Mixed configurations of SAS HDDs, SATA HDDs and SSDs within the same logical drive (RAID array) are not supported.
If the server has the corresponding RAID configuration, HDD/SSD modules can also be replaced during operation.
Onboard SATA controller
A SATA controller is integrated on the system board; up to eight SATA HDDs can be connected to the controller.
For more information on configuring the controller, see section "Configuring the
onboard SATA controller" on page 73.
RX2530 M4
Operating Manual 15
Functional overview
SAS/SATA RAID controller
The server is available with the following SAS/SATA RAID controllers for operating the internal SAS/SATA HDDs:
– Modular Host Bus Adapter with "Integrated RAID" (IR). RAID levels 0 and 1
are supported for internal HDD configurations.
– Modular RAID 0/1 controller with "MegaRAID functionality" (integrated
MegaRAID). RAID levels 0, 1, 10, 5 and 50 are supported for internal HDD configurations.
– Modular RAID 5/6 controller with "MegaRAID functionality" (MegaRAID).
RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported for internal HDD configurations. As an option, a flash backup unit (FBU) can save the memory content even if the power fails. Cache memory size of 1 GB or 2 GB is available.
I
For more information on configuring the controller, see section
"Configuring the SAS/SATA RAID controller" on page 74.
Further information on SAS/SATA RAID controllers is provided in the "Modular RAID Controller Installation Guide" (on the Fujitsu manuals server under x86 Servers - Expansion Cards - Storage Adapters - LSI SAS / SCSI RAID Controllers).
Further information on other SAS/SATA RAID controllers (e.g. for operating external SAS/SATA HDDs or tape drives) is available on the Fujitsu manuals server under x86 Servers - Expansion Cards - Storage Adapters - LSI SAS / SCSI RAID Controllers.
Optical disk drive (ODD)
An installation slot for an ultra slim ODD (optional) is available.
I
For the variant with 10x 2.5-inch HDDs there is no slot available for an ultra slim ODD.
USB connectors
4x 3.5-inch HDDs and 8x 2.5-inch HDDs chassis: There are two USB 3.0 connectors on the front and two USB 3.0 connectors at the rear.
10x 2.5-inch HDDs chassis: On the front there is one USB 2.0 connector. At the rear there are two USB 3.0 connectors.
The maximum length of the external cable are three meters.
16 Operating Manual
RX2530 M4
Functional overview
Power supply unit (PSU)
The server can be equipped with:
– with up to two AC PSUs
In its basic configuration the server has one PSU that adjusts automatically to any mains voltage in the range of 100 - 240 V (PSU Platinum, 450 W) or 200 - 240 V (PSU Titanium, 800 W). Besides the PSU, a second PSU can be installed optionally to serve as a redundant power supply. If one PSU fails, the second PSU in the redundant configuration ensures operation can continue uninterrupted and the defective PSU can be replaced during operation (hot-plug).
– with up to two DC PSUs
In its basic configuration the server has one PSU that adjusts automatically to any mains voltage in the range of -40.5 V to -57 V. Besides the PSU, a second PSU can be installed optionally to serve as a redundant power supply. If one PSU fails, the second PSU in the redundant configuration ensures operation can continue uninterrupted and the defective PSU can be replaced during operation (hot-plug).
– with one AC PSU or DC PSU and one FJBU
Fujitsu battery unit (FJBU)
FJBU behaves as a modular UPS in the server. When power fail happened, the server can operate by FJBU for a while. FJBU supports hot-plugging, and can be replaced during operation.
You can download the management software (FJBU management software) for the following OS: – Windows Server 2016 – Windows Server 2012 R2, Windows Server 2012 – Windows Server 2008 R2 SP1, Windows Server 2008 SP2
I
FJBU management software is not available in VMWare ESXi and Red Hat Enterprise Linux environment. Please use the IPMI function at Linux environment.
RX2530 M4
Operating Manual 17
Functional overview
Advanced Thermal Design
The Advanced Thermal Design option allows you to operate the system with a wider temperature range either of 5 °C to 40 °C or 5 °C to 45 °C, depending on your system and configuration.
This option can only be ordered from the manufacturer and is indicated by the respective logo on the identification rating plate.
V
CAUTION
In a system that is configured with Advanced Thermal Design, only certain components which support the respectively increased higher operating temperature range may be installed and used. For applicable restrictions, please refer to the official configurator tool.
High level of availability and data security
When memory data is accessed, 1-bit errors are identified in the main memory and automatically corrected with the error correcting code (ECC) method.
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in the event of an error and automatically "hides" the defective system components.
The PDA (Prefailure Detection and Analysis) technology from Fujitsu analyzes and monitors all components that are critical for system reliability.
A RAID controller supports different RAID levels and increase the availability and data security of the system.
The hot-plug HDD modules provide additional availability.
18 Operating Manual
RX2530 M4
Functional overview
iRMC S5 with integrated management LAN connector
The iRMC S5 (integrated Remote Management Controller) is a Baseboard Management Controller (BMC) with integrated management LAN connector and expanded functionality that was previously only available with additional plug-in cards. In this way, the iRMC S5 enables complete control of PRIMERGY servers, regardless of system status, and thus particularly the control of PRIMERGY servers that are in the "out-of-band" system status.
Major functions supported by the iRMC S5 include the following:
Browser access via iRMC S5´s own Web server
Secure communication (SSH, SSL)
Power Management for the managed server (depending on its system status)
Power Consumption Management
Connecting virtual drives as remote storage
Text-based and graphic console bypass (Advanced Video Redirection)
Remote Storage
Command Line Interface (CLI)
Simple, interactive or script-based iRMC S5configuration
Customer Self Service (CSS)
iRMC S5´s own user management
Multi-computer, global iRMC S5 user administration using an LDAP Directory Service
Automatic network configuration via DNS / DHCP
Power supply of the iRMC S5 via the system standby supply
Full-coverage alarm management
System Event Log (SEL) reading and processing
IPMI support
CIM / WS-MAN support
Internal Event Log for user login / logout auditing
RX2530 M4
Operating Manual 19
Functional overview
More information about the iRMC S5 can be found in the iRMC S5 user guides (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Out-Of-Band Management).
Server management
Server management is implemented using the ServerView Operations Manager supplied and the PDA (Prefailure Detection and Analysis) technology from Fujitsu. PDA reports the threat of a system error or overload at an early stage, allowing preventive measures to be taken.
The ServerView Operations Manager enables the management of all PRIMERGY servers in the network via a central console. The ServerView Operations Manager supports the following functions:
Round-the-clock monitoring, regardless of server status
High-performance, graphical console bypass (AVR) protected by HTTPS/SSL (128 bit)
Remote storage via USB
Remote power on
Intrusion detection in the floorstand model
Temperature monitoring of the CPU and the surrounding area
Detailed status and error reports for CPUs and main memory
Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R) in the event that memory modules or CPUs fail
Power monitoring
End-of-life monitoring of fans with prompt notification before failure
Watchdog timer for monitoring the operating system with ASR&R
Further information on the ServerView Operations Manager is provided in the associated documentation.
ServerView Installation Manager
You can configure the PRIMERGY server quickly and precisely with the ServerView Installation Manager software provided. User-guided menus are available for installing the server operating system (for further details see section "Configuring the server" on page 73).
20 Operating Manual
RX2530 M4
Functional overview
Service and support
PRIMERGY servers are easy to maintain and modular, thus enabling quick and simple maintenance.
The handles and locks (touch points) used to exchange components are colored green to ensure simple and immediate recognition.
In order to prevent the components from being damaged by incorrect handling when they are being installed and removed, the areas of all components that can be touched without damaging them are also marked green.
PRIMERGY diagnostic LEDs fitted on the system board indicate which component (memory module, CPU, fan or expansion card) is not functioning properly.
The Flash EPROM program supplied with the Fujitsu utilities supports a fast BIOS update.
With the iRMC (integrated Remote Management Controller) on the system board, the PRIMERGY RX2530 M4 server can also be maintained and serviced remotely. This enables remote diagnosis for system analysis, remote configuration and remote restart should the operating system or hardware fail.
ServerView Remote Management
ServerView Remote Management is the remote management solution from Fujitsu for PRIMERGY servers. ServerView Remote Management and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operation in the event of errors. Remote monitoring and maintenance avoids time-consuming and costly on-site repairs and reduces service costs. This leads to a reduction in the total cost of ownership and an excellent return on investment for the remote management solution. The administrator can access all system information and information from the sensors such as fan speeds or voltages via the iRMC S5's web interface (see section "iRMC S5 with integrated management LAN connector" on page 19). You can also start the text-based or graphic console bypass (Advanced Video Redirection, AVR) and connect virtual drives as remote storage.
I
More information about the iRMC S5 can be found in the iRMC S5 user guides (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Out-Of-Band Management).
RX2530 M4
Operating Manual 21
Functional overview

2.2 Server specification

This section explains the specifications for the server. The specifications for this server are liable to be updated without any notice. Please be forewarned.
System Board
System board type D3383
Chipset Intel
Processor (CPU)
®
C620
CPU quantity and type 1 or 2 Intel
®
Xeon® CPUs (Platinum, Gold, Silver,
Bronze)
Memory Modules Configuration
Memory slots 24 (12 DIMMs per CPU, 6 channels with 2 slots per
channel)
Memory slot type DIMM (DDR4)
Memory capacity
8 GB - 3072 GB
(min. - max.)
Memory protection Advanced ECC; Memory Scrubbing; SDDC; Rank
sparing memory support; Memory Mirroring support
Memory notes Memory modules with 8, 16, 32, 64 or 128 GB and
2666 MHz are available.
22 Operating Manual
RX2530 M4
Functional overview
Interfaces
USB connectors USB 3.0 connectors: 4 (2x front, 2x rear)
USB connectors (10 HDD variant)
USB 2.0 connectors: 1 (1x on front panel QRL) USB 3.0 connectors: 2 (2x rear)
Graphics (15-pin) 1x VGA (rear)
1x front VGA as an option (not for 10 HDD variant)
Serial (9-pin) 1 x serial RS-232-C, usable for iRMC S5 or system or
shared
LAN / Ethernet OCP option:
–4x 1 Gb – 2x 10 Gb – 2x 10 Gb SFP+ – 4x 10 Gb SFP+
Management LAN (RJ45)
1 x dedicated management LAN connector for iRMC S5 (10/100/1000 Mbit/s). Management LAN traffic can be switched to shared onboard Gbit LAN port.
Onboard or integrated controllers
RAID controller Modular Host Bus Adapter with "Integrated RAID" (IR).
RAID levels 0 and 1 are supported for internal HDD configurations.
SATA controller Intel
®
C620, 1 x SATA channel for ODD
LAN controller OCP based on Emulex XE100 series;
PXE-Boot via LAN from PXE server, iSCSI / FCoE boot (also diskless).
Remote Management Controller
Trusted Platform Module (TPM)
Integrated Remote Management Controller (iRMC S5), 256 MB DDR3-800 SRAM for video, IPMI 2.0 compatible
Infineon / separate module; TCG V1.2 or TCG 2.0 compliant (option)
RX2530 M4
Operating Manual 23
Functional overview
RAID controllers (expansion cards)
RAID controllers Modular RAID 0/1 controller with "MegaRAID
functionality" (integrated MegaRAID). RAID levels 0, 1, 10, 5 and 50 are supported for internal HDD configurations.
Modular RAID 5/6 controller with "MegaRAID functionality" (integrated MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported for internal HDD configurations. As an option, a flash backup unit (FBU) can save the memory content even if the power fails. Cache memory size of up to 8GB are available.
Slots
PCI-Express 3.0 x8 1x low profile
PCI-Express 3.0 x16 3x low profile (2nd CPU required for slot 4)
Slot notes One PCIe Gen3 x8 slot may be occupied with a
Modular RAID controller if configured.
Drive bays
Hard disk bay configuration
Accessible drive bays 1x 5.25/0.5-inch for DVD/RW-Blu-ray (not for 10 HDD
Notes accessible drives
24 Operating Manual
4x, 8x, 10x 2.5-inch or 4x 3.5-inch
variant)
all possible options described in relevant system configurator
RX2530 M4
Functional overview
Operating Panel
Operating buttons On/Off button
ID button
Reset button
NMI button
Status LEDs Global Error indicator (orange)
ID indicator (blue)
HDD/SSD activity indicator (green)
Power-on indicator (green)
AC connected indicator (green)
CSS indicator (orange)
Status LED at system rear side
Global error / CSS / ID indicator (orange / orange / blue)
LAN connection indicator (green)
LAN speed indicator (green/yellow)
Dimensions / Weight
Rack (W x D x H) 482.6 mm (bezel) / 435.4 mm (body) x 720.7 mm x
42.85 mm
Mounting depth rack 748.2 mm
Height unit rack 1 U
19" rackmount Yes
Mounting cable
200 mm (1000 mm rack recommended)
depth rack
Weight 8.8 kg - 16.5 kg
Weight notes actual weight may vary depending on configuration
Rack mounting kit 6.6 kg
RX2530 M4
Operating Manual 25
Functional overview
Ambient conditions
Environment class 3K2 Environment class 2K2
EN 60721 / IEC 721 Part 3-3 EN 60721 / IEC 721 Part 3-2
Temperature
Operation (3K2) 5°C ... 40°C (with ATD 40°C)
5°C ... 45°C (with ATD 45°C) 10°C ... 35°C (without ATD)
Transport (2K2) -25°C ... 60°C
Humidity 10% ... 85% (non condensing)
Condensation during operation must be avoided!
Noise level
The acoustic noise values are depending on the system configuration.
Sound power level L
WAd
(ISO 9296)
Sound pressure level at adjacent workstation
(ISO 9296)
L
pAm
min. configuration 1x PSU 1x CPU
< 5.1 B (standby) < 6.2 B (operation)
< 34 dB(A) (standby) < 44 dB(A) (operation)
max. configuration 2x PSU 2x CPU
< 5.3 B (standby) < 7.7 B (operation)
< 36 db(A) (standby) < 60 db(A) (operation)
26 Operating Manual