Fujitsu VFY:R1333SC020IN User Manual

Operating Manual - English
FUJITSU Server PRIMERGY RX1330 M3
Operating Manual
March 2017
CommentsSuggestionsCorrections
The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs.
Feel free to send us your comments by e-mail to
manuals@ts.fujitsu.com.
Certified documentation according to DIN EN ISO 9001:2008
To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2008.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademarks
Copyright 2017 FUJITSU LIMITED
All rights reserved. Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.
– The contents of this manual may be revised without prior notice.
– Fujitsu assumes no liability for damages to third party copyrights or other rights arising from
the use of any information in this manual.
– No part of this manual may be reproduced in any without the prior written permission of
Fujitsu.
Microsoft, Windows, Windows Server, and Hyper-V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries.
Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.
Before reading this manual
For your safety
This manual contains important information for safely and correctly using this product.
Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product.
Radio interference
This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A
Aluminum electrolytic capacitors
The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke.
As a guideline, in a normal office environment (25°C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period.
High safety use
This product has been designed and manufactured to be used in commercial and/or industrial areas as a server.
When used as visual display workplace, it must not be placed in the direct field of view to avoid incommoding reflections (applies only to TX server systems).
The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured.
RX1330 M3 Operating Manual
These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.
Measures against momentary voltage drop
This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended.
(This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.)
Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan
Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law.
Harmonic Current Standards
This product conforms to harmonic current standard JIS C 61000-3-2.
Only for Japan: About SATA HDDs
The SATA version of this server supports HDDs with SATA/BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of HDD used.
Please refer to the following internet address for further information on the usage and operation conditions of each available type of HDD:
http://jp.fujitsu.com/platform/server/primergy/harddisk/
Operating Manual RX1330 M3
Only for Japan:
I Although described in this manual, some sections do not apply to Japan.
These options and routines include:
– CSS (Customer Self Service)
– UFM (USB Flash Module)
RX1330 M3 Operating Manual
Operating Manual RX1330 M3

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.1 Concept and target groups for this manual . . . . . . . . . 11
1.2 Documentation overview . . . . . . . . . . . . . . . . . . . 12
1.3 Notational conventions . . . . . . . . . . . . . . . . . . . . 13
2 Functional overview . . . . . . . . . . . . . . . . . . . . . . 15
2.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.2 Server specification . . . . . . . . . . . . . . . . . . . . . . 23
3 Installation steps, overview . . . . . . . . . . . . . . . . . . 31
4 Important information . . . . . . . . . . . . . . . . . . . . . 33
4.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 33
4.2 ENERGY STAR . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.3 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.4 FCC Class A Compliance Statement . . . . . . . . . . . . . 43
4.5 Transporting the server . . . . . . . . . . . . . . . . . . . . 44
4.6 Notes on installing the server in the rack . . . . . . . . . . . 44
4.7 Environmental protection . . . . . . . . . . . . . . . . . . . 45
5 Hardware installation . . . . . . . . . . . . . . . . . . . . . 47
5.1 Unpacking the server . . . . . . . . . . . . . . . . . . . . . 48
5.2 Installing/removing the server in/from the rack . . . . . . . 48
5.3 Connecting devices to the server . . . . . . . . . . . . . . . 50
5.3.1 Connecting the monitor . . . . . . . . . . . . . . . . . . . . . 52
RX1330 M3 Operating Manual
Contents
5.4 Connecting the server to the mains . . . . . . . . . . . . . . 52
5.4.1 Using cable ties (standard PSU) . . . . . . . . . . . . . . . . . 53
5.4.2 Using the cable clamps (hot-plug PSU) . . . . . . . . . . . . . . 54
5.5 Notes on connecting/disconnecting cables . . . . . . . . . . 55
6 Starting up and operation . . . . . . . . . . . . . . . . . . . . 57
6.1 Controls and indicators . . . . . . . . . . . . . . . . . . . . . 57
6.1.1 Server front . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
6.1.1.1 Controls on the front panel . . . . . . . . . . . . . . . . . . 57
6.1.1.2 Indicators on the front panel . . . . . . . . . . . . . . . . . . 59
6.1.1.3 Indicators on the accessible drives/components . . . . . . . 62
6.1.2 Server rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
6.1.2.1 Indicators on the I/O panel . . . . . . . . . . . . . . . . . . 64
6.1.2.2 Indicator on hot-plug PSUs . . . . . . . . . . . . . . . . . . 68
6.1.2.3 Indicator on Fujitsu battery unit (FJBU) . . . . . . . . . . . . 69
6.2 ID card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
6.3 Switching the server on and off . . . . . . . . . . . . . . . . 71
6.4 Configuring the server . . . . . . . . . . . . . . . . . . . . . 73
6.4.1 Configuring the onboard SATA controller . . . . . . . . . . . . . 73
6.4.2 Configuring the SAS/SATA RAID controller . . . . . . . . . . . . 74
6.4.3 Configuring the server and installing the operating system
with the ServerView Installation Manager . . . . . . . . . . . . . 74
6.4.4 Configuring the server and installing the operating system
without the ServerView Installation Manager . . . . . . . . . . . 75
6.5 Cleaning the server . . . . . . . . . . . . . . . . . . . . . . . 76
7 Property and data protection . . . . . . . . . . . . . . . . . . 77
7.1 BIOS Setup security functions . . . . . . . . . . . . . . . . . 77
8 Troubleshooting and tips . . . . . . . . . . . . . . . . . . . . 79
8.1 Power-on indicator remains unlit . . . . . . . . . . . . . . . . 79
8.2 Server switches itself off . . . . . . . . . . . . . . . . . . . . 80
8.3 Screen remains blank . . . . . . . . . . . . . . . . . . . . . . 80
Operating Manual RX1330 M3
Contents
8.4 Flickering stripes on monitor screen . . . . . . . . . . . . . 81
8.5 No screen display or display drifts . . . . . . . . . . . . . . 81
8.6 No mouse pointer displayed on screen . . . . . . . . . . . . 81
8.7 Incorrect date and time . . . . . . . . . . . . . . . . . . . . 82
8.8 Drives reported as “dead” when starting system . . . . . . 82
8.9 Added drive reported as defective . . . . . . . . . . . . . . 82
8.10 Error message on screen . . . . . . . . . . . . . . . . . . . 83
8.11 Expansion cards or onboard devices not recognized . . . . 83
8.12 Temperature warning . . . . . . . . . . . . . . . . . . . . . . 83
8.13 No effect of keyboard or mouse . . . . . . . . . . . . . . . . 83
8.14 ODD cannot read data . . . . . . . . . . . . . . . . . . . . . 84
RX1330 M3 Operating Manual
Contents
Operating Manual RX1330 M3

1 Introduction

The PRIMERGY RX1330 M3 server is an Intel®-based server for small and medium-sized networks and can be used in the rack systems made by Fujitsu and in current standard rack systems made by various other manufacturers.
Thanks to its highly developed hardware and software components, the PRIMERGY RX1330 M3 server offers a high level of data security and availability. These include the Server Management ServerView Suite, Prefailure Detection and Analysis (PDA) and Automatic Server Reconfiguration and Restart (ASR&R).
Security functions in the BIOS Setup and on the system board protect the data on the server against manipulation. Additional security is provided by the lockable rack door.
The server occupies 1 height unit in the rack.

1.1 Concept and target groups for this manual

This operating manual describes how to install, set up and operate your server.
This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. It contains all the information you need to put your PRIMERGY RX1330 M3 into operation.
To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system.
RX1330 M3 Operating Manual 11
Introduction

1.2 Documentation overview

More information on your PRIMERGY RX1330 M3 can be found in the following documents:
– "Quick Start Hardware - FUJITSU Server PRIMERGY RX1330 M3"
– "ServerView Quick Start Guide"
– "Safety Notes and Regulations" manual
" 安全上のご注意 " for Japan
– "Warranty" manual
" 保証書 " for Japan
– "ServerView Suite Local Service Concept - LSC" manual
– "Returning used devices" manual and "Service Desk" leaflet
" サポー ト &サービ ス " for Japan
– "FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance
Manual"
– "D3375 BIOS Setup Utility for FUJITSU Server PRIMERGY RX1330 M3
Reference Manual"
I All documentation on PRIMERGY hardware and ServerView software is
available online from the Fujitsu manuals server at:
http://manuals.ts.fujitsu.com
12 Operating Manual RX1330 M3
For Japan:
http://www.fujitsu.com/jp/products/computing/servers/primergy/manual/
The complete PRIMERGY documentation set can also be downloaded as a DVD ISO image at:
ftp://ftp.ts.fujitsu.com/images/serverview/manuals
For Japan:
http://www.fujitsu.com/jp/products/computing/servers/primergy/downloads/
Introduction
Further sources of information:
– ServerView Suite Glossary – Manual for the monitor – Documentation for the boards and drives – Operating system documentation – Information files in your operating system

1.3 Notational conventions

The following notational conventions are used in this manual:
Text in italics indicates commands or menu items.
"Quotation marks" indicate names of chapters and terms that are being
emphasized.
Ê describes activities that must be performed in the order
shown.
V CAUTION! pay particular attention to texts marked with this symbol.
Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.
I indicates additional information, notes and tips.
RX1330 M3 Operating Manual 13
14 Operating Manual RX1330 M3
Introduction

2 Functional overview

This section provides information on the features and technical data of the PRIMERGY RX1330 M3 server.

2.1 Features

Intel® Xeon®, Pentium®, or Core i3 CPU
The server has an Intel processing.
Customer Self Service (CSS)
The PRIMERGY Customer Self Service (CSS) concept enables you to identify and replace the affected component yourself in the case of certain error scenarios.
In the CSS concept, you can replace the following components yourself in the event of an error:
– Hot-plug HDD/SSD modules
– Hot-plug PSUs
– Memory modules
®
Xeon®, Pentium®, or Core i3 CPU for high-speed data
– System fans
– Expansion cards
For information on replacing these components, see the "FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual".
CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises.
In addition, CSS errors are displayed in the ServerView Operations Manager, the server management software from Fujitsu.
In the event of errors, the ServerView Operations Manager refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question. (This feature is not available for Japan.)
RX1330 M3 Operating Manual 15
Functional overview
I Further information on the CSS concept is provided in the "PRIMERGY
ServerView Suite Local Service Concept - LSC" manual on the Fujitsu manuals server.
For the latest information on optional products provided for the RX1330 M3 see the configurator of the server:
http://ts.fujitsu.com/products/standard_servers/index.html
For Japan:
http://www.fujitsu.com/jp/products/computing/servers/primergy/
System board
The features of the system board are described in the "FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual" for the hardware and in the "D3375 BIOS Setup Utility for FUJITSU Server PRIMERGY RX1330 M3 Reference Manual" for the firmware.
Trusted Platform Module (TPM)
A Trusted Platform Module (TPM) for safer storage of keys can be implemented as an option. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption).
The TPM is activated via the BIOS system (for more information, refer to the “D3375 BIOS Setup Utility for FUJITSU Server PRIMERGY RX1330 M3 Reference Manual").
V CAUTION!
– When using the TPM, note the program descriptions provided by the
third party manufacturers.
– You must also create a backup of the TPM content. To do this, follow
the third party manufacturer's instructions. Without this backup, if the TPM or the system board is faulty you will not be able to access your data.
– If a failure occurs, please inform your service about the TPM
activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content.
16 Operating Manual RX1330 M3
Functional overview
Hard disk drives (HDDs)
The server is shipped with one of the following drive cages:
– For up to four 3.5-inch SAS/SATA HDD modules:
Up to four 3.5-inch SAS/SATA HDD modules can be used in the drive cage. Each HDD module can accommodate an SAS/SATA HDD with a maximum height of 1 inch. The module is connected to the SAS/SATA backplane wirelessly. This allows HDD modules to be plugged in or pulled out easily.
Hybrid configurations of SAS and SATA HDD modules within one drive cage are not supported.
– For up to four, eight or ten 2.5-inch SAS/SATA HDD modules or 2.5-inch
SATA SSD modules:
Each module can accommodate SAS/SATA HDD or an SATA SSD with a
2.5-inch format. The HDD/SSD modules are connected to the SAS/SATA backplane wirelessly. This allows modules to be plugged in or pulled out easily.
I Up to ten SAS/SATA drives are controlled by the SAS/SATA RAID
controller already installed.
I Configurations with Eco SATA can only be mixed with BC SATA HDD
type. SAS and BC SATA drives with the same size can be mixed, but not used in the same logical RAID volume.
Hybrid configurations of SATA HDD and SATA SSD modules are supported.
If the server has the corresponding RAID configuration, the HDD/SSD modules can also be replaced during operation.
Onboard SATA controller
A SATA controller is integrated on the system board; up to four SATA HDDs can be connected to the controller. The LSI Embedded MegaRAID software (SATA Software RAID) supports RAID levels 0, 1 and 10.
For more information on configuring the controller, see section "Configuring the
onboard SATA controller" on page 73.
RX1330 M3 Operating Manual 17
Functional overview
SAS/SATA RAID controller
The server is available with the following SAS/SATA RAID controllers for operating the internal SAS/SATA HDDs:
– Modular Host Bus Adapter with "Integrated RAID" (IR). RAID levels 0 and 1
are supported for internal HDD configurations.
– Modular RAID 0/1 controller with "MegaRAID functionality" (integrated
MegaRAID). RAID levels 0, 1, 10, 5 and 50 are supported for internal HDD configurations.
– Modular RAID 5/6 controller with "MegaRAID functionality" (MegaRAID).
RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported for internal HDD configurations. As an option, a flash backup unit (FBU) can save the memory content even if the power fails. Cache memory size of 1GB or 2GB are available.
I For more information on configuring the controller, see section
"Configuring the SAS/SATA RAID controller" on page 74.
Further information on SAS/SATA RAID controllers is provided in the "Modular RAID Controller Installation Guide" (on the Fujitsu manuals server under x86 Servers - Expansion Cards - Storage Adapters - LSI SAS / SCSI RAID Controllers).
Further information on other SAS/SATA RAID controllers (e.g. for operating external SAS/SATA HDDs or tape drives) is available on the Fujitsu manuals server under x86 Servers - Expansion Cards - Storage Adapters - LSI SAS / SCSI RAID Controllers.
Optical disk drive (ODD)
An installation slot for an ultra slim ODD (optional) is available.
I For the variant with 10 HDDs there is no slot available for an ultra slim
ODD.
Power supply unit (PSU)
In its basic configuration the server has a standard PSU or a hot-plug PSU that adjusts automatically to any mains voltage in the range 100 V - 240 V. Besides the hot-plug PSU, a second hot-plug PSU can be installed optionally to serve as a redundant Power Supply. If one PSU fails, the second PSU in the redundant configuration ensures operation can continue uninterrupted.
18 Operating Manual RX1330 M3
Functional overview
Fujitsu battery unit (FJBU)
FJBU behaves as a modular UPS in the server. When power fail happened, the server can operate by FJBU for a while. FJBU supports hot-plugging, and can be replaced during operation.
You can download the management software (FJBU management software) for the following OS: – Windows Server 2016 – Windows Server 2012 R2, Windows Server 2012 – Windows Server 2008 R2 SP1, Windows Server 2008 SP2
I FJBU management software is not available in Red Hat Enterprise Linux
environment. Please use the IPMI function at Linux environment.
Advanced Thermal Design
The Advanced Thermal Design option allows you to operate the system with a wider temperature range of 5 °C to 40 °C, depending on your system and configuration.
This option can only be ordered from the manufacturer and is indicated by the respective logo on the identification rating plate.
V CAUTION
In a system that is configured with Advanced Thermal Design, only certain components which support the respectively increased higher operating temperature range may be installed and used. For applicable restrictions, please refer to the official configurator tool.
High level of availability and data security
When memory data is accessed, 1-bit errors are identified in the main memory and automatically corrected with the error correcting code (ECC) method. ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in the event of an error and automatically "hides" the defective system components. The PDA (Prefailure Detection and Analysis) technology from Fujitsu analyzes and monitors all components that are critical for system reliability. A RAID controller supports different RAID levels and increase the availability and data security of the system. The hot-plug HDD modules provide additional availability.
RX1330 M3 Operating Manual 19
Functional overview
iRMC S4 with integrated management LAN connector
The iRMC S4 (integrated Remote Management Controller) is a Baseboard Management Controller (BMC) with integrated management LAN connector and expanded functionality that was previously only available with additional plug-in cards. In this way, the iRMC S4 enables complete control of PRIMERGY servers, regardless of system status, and thus particularly the control of PRIMERGY servers that are in the "out-of-band" system status.
Major functions supported by the iRMC S4 include the following:
Browser access via iRMC S4´s own Web server
Secure communication (SSH, SSL)
Power Management for the managed server (depending on its system
status)
Power Consumption Management
Connecting virtual drives as remote storage
Text-based and graphic console bypass (Advanced Video Redirection)
Remote Storage
Command Line Interface (CLI)
Simple, interactive or script-based iRMC S4configuration
Customer Self Service (CSS)
iRMC S4´s own user management
Multi-computer, global iRMC S4 user administration using an LDAP
Directory Service
Automatic network configuration via DNS / DHCP
Power supply of the iRMC S4 via the system standby supply
Full-coverage alarm management
System Event Log (SEL) reading and processing
IPMI support
CIM / WS-MAN support
Internal Event Log for user login / logout auditing
20 Operating Manual RX1330 M3
Functional overview
More information about the iRMC S4 can be found in the "iRMC S4 - integrated Remote Management Controller" user guide (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Out-Of-Band Management).
Server management
Server management is implemented using the ServerView Operations Manager supplied and the PDA (Prefailure Detection and Analysis) technology from Fujitsu. PDA reports the threat of a system error or overload at an early stage, allowing preventive measures to be taken.
The ServerView Operations Manager enables the management of all PRIMERGY servers in the network via a central console. The ServerView Operations Manager supports the following functions:
Round-the-clock monitoring, regardless of server status
High-performance, graphical console bypass (AVR) protected by
HTTPS/SSL (128 bit)
Remote storage via USB
Remote power on
Temperature monitoring of the CPU and the surrounding area
Detailed status and error reports for CPUs and main memory
Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R)
in the event that memory modules or CPUs fail
Power monitoring
End-of-life monitoring of fans with prompt notification before failure
Watchdog timer for monitoring the operating system with ASR&R
Further information on the ServerView Operations Manager is provided in the associated documentation.
ServerView Installation Manager
You can configure the PRIMERGY server quickly and precisely with the ServerView Installation Manager software provided. User-guided menus are available for installing the server operating system (for further details see section "Configuring the server" on page 73).
RX1330 M3 Operating Manual 21
Functional overview
Service and support
PRIMERGY servers are easy to maintain and modular, thus enabling quick and simple maintenance.
The handles and locks (touch points) used to exchange components are colored green to ensure simple and immediate recognition.
In order to prevent the components from being damaged by incorrect handling when they are being installed and removed, the areas of all components that can be touched without damaging them are also marked green.
PRIMERGY diagnostic LEDs fitted on the system board indicate which component (memory module, CPU, fan or expansion card) is not functioning properly.
The Flash EPROM program supplied with the Fujitsu utilities supports a fast BIOS update.
With the iRMC (integrated Remote Management Controller) on the system board, the PRIMERGY RX1330 M3 server can also be maintained and serviced remotely. This enables remote diagnosis for system analysis, remote configuration and remote restart should the operating system or hardware fail.
ServerView Remote Management
ServerView Remote Management is the remote management solution from Fujitsu for PRIMERGY servers. ServerView Remote Management and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operation in the event of errors. Remote monitoring and maintenance avoids time-consuming and costly on-site repairs and reduces service costs. This leads to a reduction in the total cost of ownership and an excellent return on investment for the remote management solution. The administrator can access all system information and information from the sensors such as fan speeds or voltages via the iRMC S4's Web interface (see section "iRMC S4 with integrated management LAN connector" on page 20). You can also start the text-based or graphic console bypass (Advanced Video Redirection, AVR) and connect virtual drives as remote storage.
I More information about the iRMC S4 can be found in the "iRMC S4 -
integrated Remote Management Controller" user guide (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Out-Of- Band Management).
22 Operating Manual RX1330 M3
Functional overview

2.2 Server specification

This section explains the specifications for the server. The specifications for this server are liable to be updated without any notice. Please be forewarned.
System Board
System board type D3375
Chipset Intel
Processor (CPU)
®
C236
CPU quantity and type 1x Intel
®
Xeon® E3-1200v6 family / Pentium® /
Core i3
Memory Modules Configuration
Memory slots 4 (2 banks with 2 DIMMs each)
Memory slot type DIMM (DDR4)
Memory capacity
4 GB - 64 GB
(min. - max.)
Memory protection ECC
Interfaces
USB 3.0 connectors 6 (2x front, 4x rear)
USB 2.0 connectors
1x on front panel on QRL
(for up to 10 HDDs)
USB 3.0 connectors
4x rear
(for up to 10 HDDs)
Graphics (15-pin) 1 x VGA (rear); 1x front VGA as an option (not for up
to 10 HDDs)
Serial (9-pin) 1 x serial RS-232-C, usable for iRMC S4 or system
or shared
LAN/Ethernet (RJ-45) 1 x standard LAN, 1 x shared LAN
RX1330 M3 Operating Manual 23
Functional overview
Management LAN (RJ45)
Onboard or integrated controllers
RAID Controller Modular Host Bus Adapter with "Integrated RAID"
SATA Controller A 6-port SATA controller is integrated on the system
Remote Management Controller
Trusted Platform Module (TPM)
1 x dedicated management LAN port for iRMC S4 (10/100/1000 Mbit/s); management LAN traffic can be switched to shared onboard Gbit LAN port
(IR). RAID levels 0 and 1 are supported for internal HDD configurations.
Modular RAID 0/1 controller with "MegaRAID functionality" (integrated MegaRAID). RAID levels 0, 1, 10, 5 and 50 are supported for internal HDD configurations.
Modular RAID 5/6 controller with "MegaRAID functionality" (MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported for internal HDD configurations.
board; up to four SATA HDDs can be connected to the controller. The LSI Embedded MegaRAID software (SATA Software RAID) supports RAID levels 0, 1 and 10.
Integrated Remote Management Controller (iRMC S4), 256 MB DDR3-800 SRAM for video, IPMI 2.0 compatible
Infineon TCG V1.2 compliant (option) Infineon TCG V2.0 compliant (option)
Slots
PCI Express 3.0 x8 2 x low-profile length 175 mm; one slot may be
PCI Express 3.0 x4 (mech. x8)
Slot notes Optional support of 1x full height PCIe Gen3 x8 card,
24 Operating Manual RX1330 M3
occupied by Modular RAID
1 x low-profile
instead of 1x PCIe Gen3 x4 and 1x PCIe Gen3 x8.
Functional overview
Drive bays
Hard disk bay configuration
4/8/10 x 2.5-inch for hot-plug SAS/SATA HDD modules or SATA SSD modules
4 x 3.5-inch for hot-plug SAS/SATA HDD modules
Accessible drive bays 1 x 5.25/0.4-inch for 1x ultra slim ODD
Notes accessible drives all possible options described in relevant system
configurator
Operating Panel
Operating buttons On/Off button
ID button
Reset button
NMI button
Status LEDs Global Error indicator (orange)
ID indicator (blue)
HDD/SSD activity indicator (green)
Power-on indicator (green)
AC connected indicator (green)
CSS indicator (orange)
Status LED at system rear side
Global error / CSS / ID indicator (orange / orange / blue)
LAN connection indicator (green)
LAN speed indicator (green/yellow)
RX1330 M3 Operating Manual 25
Functional overview
Dimensions/Weight
Width
482.6 mm (bezel) / 435.4 mm (body)
Depth 611 mm
Installation depth in
572 mm (without projecting parts)
rack
Height 42.8 mm / 1 HU
Weight
approx. 8.8 kg – 13.2 kg
Weight notes Weight may vary depending on actual configuration
Rack mounting kit Rack mounting kit as option
Ventilation clearance
At least 200 mm on the front and rear
Ambient conditions
Environment class 3K2 Environment class 2K2
EN 60721 / IEC 721 Part 3-3 EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2) 5 ° C ... 40 ° C (with ATD)
10 °C ... 35 °C (without ATD)
Transport (2K2) -25 °C ... 60 °C
Humidity 10% ... 85% (non condensing)
Condensation during operation must be avoided!