PX Series Program Loader
User’s Guide
The PX Series Loader can be used with all models in the PX Series including the PXV3 controller.The
PXV3, however, requires a special connector which is not yet available. The loader allows the PC to read
from a controller and write to the controller. It also has the ability to download the data to a file and to
upload from a file to the controller.
Kit includes
• Loader Box with cables
• Three 3.5” diskettes, software version 1.0
System Requirements
• PC running Windows™
• 5V DC Power Supply — TTI stocks Model No. SP-0305. Call Sales for more information.
Software Installation
1. Insert Disk 1 into the computer. Click on “Px_Disk1” icon. A dialog box appears asking for a pathname.
Type in “C:\PXLOADER”and click on “OK.”Wait until the files are copied.
2. Repeat Step 1 for disks 2 and 3.
3. Open the folder “C:\PXLOADER\Disk 1” and click on “Setup” (the one with the computer icon).
4.The loader program will be installed under “C:\Program Files\PX,” by default.
Wiring
Precautions
• Power On procedure
Do not turn on power to the controller until the wiring is completed.
Power up the controller first, and then the loader.
• Power Off procedure
Turn off power to the loader first, and then to the controller.
Disconnect the loader from the controller.
• Make sure power to the loader does not exceed 5.5V DC.
Set up the
wiring as
shown:
Operation
• Select “Start → Program → PX” to run the program.
• A dialog box appears. Type 2, or the appropriate number, for COM port and hit “Enter.”