Thank you for purchasing this RS-485 communications card "OPC-E1-RS." Installing this card to your FRENIC-Multi enables RS-485 communication.
1. Check that:
H
ooks
(2) The RS-485 communications card is not damaged during transportation--no
defective devices, dents or warps.
(3) The model name "OPC-E1-RS" is printed on the RS-485 communications
card. (See Figure 1.)
If you suspect the product is not working properly or if you have any questions about your product, contact the shop where you bought the product or your local Fuji branch office.
Figure 1 Figure 2
Model name
SW9
SW10
2. Installation
When handling the RS-485 communications card and interface PCB, take any antistatic measure or hold their hooks taking care not to directly touch their cir­cuit boards; otherwise, the static electricity charged in your body may damage them.
(1) If more than one inverter is connected in your system and you will install
the RS-485 communications card to the terminal inverter, then be sure to turn SW9 (shown in Figure 1) on the card to the ON position.
Interface PCB
(2) If the terminal cover is installed, insert your finger into the opening (next to
"PULL") provided in the bottom of the terminal cover and pull the cover towards you.
For details on how to remove the terminal cover, refer to the
FRENIC-Multi Instruction Manual (INR-SI47-1204-E), Chapter 2, Section
Figure 3
2.3 "Wiring."
(3) If the interface printed circuit board (interface PCB) is installed, push the
hooks provided on both ends of the PCB and pull it up with both hands as shown in Figure 3. (Store the removed interface PCB for future use.)
(4) Connect the CN3 connector (shown in Figure 2) on the RS-485 communi-
cations card to the connector on the inverter until it clips into place.
(5) For inverters of
less than 7.5 HP: Before reinstalling the terminal cover, cut
off the two barriers (see Figure 4) of the RS-485 communications cable outlets on the main circuit terminal block cover.
(6) Fit the latches provided on the upper end of the terminal cover into the
openings in the inverter, then close the terminal cover, taking care not to pinch control signal lines.
When reinstalling the terminal cover, refer to the FRENIC-Multi Instruc-
tion Manual (INR-SI47-1204-E), Chapter 2, Section 2.3 "Wiring."
RS-485 communications card
Main circuit terminal block cover
Barriers of the RS-485 communications cable outlets
Figure 4
For inverters of less than 7.5 HP: When performing the wiring for the
main circuit terminals, remove the RS-485 communications card before­hand.
When replacing the conventional FVR-E11S series with the FRENIC-Multi series, be sure to turn signal switch SW10 to the
"2" position (in Figure 1). The pin assignment of this RS-485 communications card is different from that of the FVR-E11S's RJ-45 connector used for RS-485 communication. For details, refer to the RS-485 Communication User's Manual (MEH448b).
• If a communications error occurs due to a communications cable too long and the transmission speed too high, wind 3 turns of a communications cable through a noise reduction core (e.g., MA055 38.1/19/12.7A manufactured by JFE Ferrite Corpora-
tion).
H
CN3
ooks
Fuji Electric Systems Co., Ltd. Fuji Electric Corp.of America
47520 Westinghouse Drive Fremont, CA 94539, U.S.A. Tel.+1-510-440-1060 Fax.+1-510-440-1063
http://www.fujielectric.com/fecoa/
Toll-free support 1-888-900-FUJI(3854)
INR-SI47-1089-EU REV. 052010 Information subject to change without notice.