80 PLUS Verification and Testing Repor
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
Ecos ID #
Manufacturer
Model Number
Serial Number
Year
Type
Test Date
Rated Specifications
Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz. Input AC Current Waveform (ITHD = 25.48%, 50% Load)
I
RMS
A
0.55 0.98
1.34 0.97 25.5% 50%
2.77 0.97 25.1% 100%
Rated Output Power
PF
791
FSP
FSP250-60GHT
S8151000046
2008
TFX
7/2/2008
Input Voltage
Input Current
Input Frequency
(%)
Load
(%)
I
THD
15.5% 20%
Fraction
of Load
Light
Typical
Full
Value Units
100-240 Volts
50-60 Hz
Input
Watts
62 11.6/0 3.4/1.4 5.1/1.5 5.2/0.2 52
149 11.7/0.1 3.3/3.1 5/3.6 5.1/0.5 127
308 11.7/0.3 3.3/6.3 5/7.1 5/1 250
85.12%
83.77%
YES
55 Amps
250 Watts
DC Terminal Voltage (V)/ DC Load Current (A)
12V (cumulative of 12V1, 12V2, etc.)
12.2/3.1
12.2/7.7
12/15.5
Input Current and Voltage Waveforms
200
150
100
50
0
0 0.003 0.006 0.009 0.012 0.015
-50
Voltage (V)
-100
-150
-200
-12V 3.3V 5V* 5VSB
Time (s)
Voltage Current
Output
Watts
15
10
5
0
-5
-10
-15
Efficiency
85.01%
85.12%
81.18%
Current (A)
%
350
300
250
200
150
Power (Watts)
100
50
0
20% 50% 100%
Input and Output Power
Input Watts
Output Watts
Loading (% of Rated Output Power)
These tests were conducted by a third party independent testing firm on behalf
of the 80 PLUS
highly-efficient power supplies (greater than 80% effic ienc y in t he ac tive
mode) in technology applications. http://www.80plus.org/
.
90%
80%
70%
60%
Efficiency (%)
50%
40%
30%
0% 25% 50% 75% 100% 125%
®
Program. 80 PLUS is a certification program to promote
Efficiency of the Power Supply
Efficiency %
Loading (% of Rated Output Power)