FSP FSP1200-50AAG Service Manual

5 (2)
FSP FSP1200-50AAG Service Manual

IPC PSU FSP1200-50AAG

DESCRIPTION

FSP1200-50AAG is an industrial level of switching power supply. The power supply comes to offer the total power capacity up to 1200 Watts, and uses unique active PFC (Power Factor Correction) circuit design with its high-load electrical components, makes it to be perfectly used in an industrial environment. In addition, with its full range of input and output electrical features, the power supply is ideally the best choice for server, workstation, communication or any other automation applications to use. The product also complies with the latest safety and EMC standards, which is perfectly to meet various regulations worldwide.

APPLICATION

For standard, advanced workstation, server and industrial power system.

FEATURES

85 Plus Gold

Low Ripple & Noise

Output over voltage protection Short circuit protection on all outputs Resettable power shut down

INTERNAL 4 cm fan 100% burn-in under high ambient temperature(50 )

Vacuum-impregnated transformer

MTBF:100K hours at 25

100% Hi-pot tested Line input fuse protection

WATTAGE

Wattage: 1200W

DIMENSION

Dimension: 190mm(L) x 150mm(W) x

86mm(H)

PRODUCT HIGHLIGHT

Efficiency Level:

80 Plus Gold

Altitude:

5000M

INPUT SPECIFICATION

Input Range:

90-264 Vac

Input Frequency:

47-63 Hz

Input Current:

115V@

12.0 Amps-rms maximum

 

230V@

6.0 Amps-rms maximum

GENERAL SPECIFICATION

Effciency:

90% 230VAC

Voltage

+3.3V, +12V, +5V, +5SB: ±5%

Regulation:

-12V: ±10%

*Output Voltage and Current Rating

SAFETY STANDARD APPAOVAL

OUTPUT SPECIFICATION

Hold up Time:

115V/60Hz 17mSec.

 

Minimum@100% Load,

 

230V/50Hz 17mSec.

Ouput Voltage

Minimum,@100% Load

+3.3Vdc output : +3.76 Vdc

Regulation:

minimum, + 4.8Vdc

 

maximum

 

+5Vdc output : +5.75 Vdc

 

minimum, + 7.0Vdc

 

maximum

 

+12Vdc output : +13.5 Vdc

 

minimum, + 15.5Vdc

Output Rise Time:

maximum

115V-rms/230V-rms 5V

 

20ms Maximum

 

115V-rms/230V-rms 12V

Ripple & Noise:

20ms Maximum

3.3V:50mV p-p

 

5V:50mV p-p

 

12V1:120mV p-p

 

-12V:120mV p-p

 

5Vsb:50mV p-p

ENVIRONMENTAL SPECIFICATION

TEMP.Range:

Storage Temperature: -

MTBF:

20°C to + 80

The power supply have a

 

minimum predicted

 

MTBF(MIL-HDBK-217) of

 

100,000 hours of continuous

 

operation at 25 ,

 

maximum-output load, and

 

nominal AC inout voltage

 

+3.3V

+5V

+12V1

-12V

+5Vsb

Ripple-Noise(R-P) mV

50mV

50mV

120mV

120mV

50mV

Regulation Load %

±5%

±5%

±5%

±10%

±5%

Output Max.(A)

30A

30A

100A

0.8A

4A

Output Min.(A)

0A

0.1A

0.2A

0A

0A

NOTES

Maximum continuous total DC output power should not exceed 1200W.

Maximum continuous combined load on +3.3DC and +5VDC outputs shall not exceed 150W.

Ripple and noise measurements shall be made under all specified load conditions through a single pole low pass filter with 20MHz cutoff frequency. Outputs shall bypassed at the connector with a 0.1uF ceramic disk capacitor and a 10uF electrolytic capacitor to simulate system loading.

This content is subject to change, please refer to specification for more detail.

FSP reserve the right to change the content without prior notice

Loading...