Triathlon Series Gas Fryers
Installation & Operation Manual
TABLE OF CONTENTS
Page #
1. INTRODUCTION 1-1
1.1 After Purchase 1-1
1.2 Ordering Parts 1-1
1.3 Service Information 1-1
1.4 Safety Information 1-2
2. IMPORTANT INFORMATION 2-1
2.1 Product Description 2-1
2.2 Principles of Operation 2-1
2.3 Rating Plate 2-1
2.4 Pre-Installation 2-1
2.5 Air Supply and Ventilation 2-3
2.6 Equipment Installed at High Altitudes 2-3
2.7 Receiving and Unpacking Equipment 2-4
3. INSTALLATION 3-1
3.1 Installing the Fryer 3-1
3.2 Leveling the Fryer 3-1
3.3 Gas Connections 3-2
4. FRYER OPERATIONS 4-1
4.1 Initial Start-up 4-1
4.2 Boil-Out Procedure 4-3
4.3 Final Preparation 4-5
4.4 Extending Oil/Shortening Life 4-5
4.5 Opening: Beginning the Workday 4-6
4.6 Filtering Basics 4-6
4.7 Closing: End of Day 4-7
4.8 Fryer Shutdown 4-7
Triathlon Series Gas Fryers
Installation & Operation Manual
TABLE OF CONTENTS (cont.)
Page #
5. PREVENTATIVE MAINTENANCE 5-1
5.1 General 5-1
6. WIRING DIAGRAMS 6-1
6.1 Robert Shaw Gas-Valve Wiring 6-1
7. PARTS LIST 7-1
7.1 Accessories 7-1
7.2 Cabinetry and Related Components 7-2
7.3 Frypots, Flues and Drain Valves 7-4
7.4 Gas Valve and Burner Components 7-5
7.5 Thermostat, High-Limit, Pilot and Related Components 7-6
TRIATHLON SERIES GAS FRYERS
CHAPTER 1: INTRODUCTION
1.1 After Purchase
In order to improve service, have the following chart filled in by the Frymaster/Dean Authorized Service Technician who installs this equipment.
Authorized Service Technician/FASC Address
Telephone/Fax Model Number Serial Number Gas Type
1.2 Ordering Parts
Customers may order parts directly from their local factory authorized service center. For this address and phone number, contact your factory authorized service center or call the Frymaster/Dean Service Hotline phone number, 1-800-551-8633.
To speed up your order, provide the model number, serial number, gas type, part needed, item part number (if known), and quantity needed.
Model Number Type Serial Number Optional Equipment Item Part Number Quantity Needed
1.3 Service Information
Call the Dean Service Hotline, 1-800-551-8633, for the location of your nearest factory authorized service center. To assist you more efficiently, always provide the service technician with the model number, gas type, serial number, and the nature of the problem.
Model Number Type Serial Number Optional Equipment Nature of Problem
1-1
TRIATHLON SERIES GAS FRYERS
CHAPTER 1: INTRODUCTION
1.4 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly.
Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones below.
CAUTION boxes contain information about actions or conditions that may cause or result in a malfunction of your system.
CAUTION
Example of a CAUTION box.
WARNING boxes contain information about actions or conditions that may cause or result in damage to your system, and which may cause your system to malfunction.
WARNING
Example of a WARNING box.
DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage to your system and/or cause your system to malfunction.
DANGER
Hot cooking oil causes severe burns. Never attempt to move a fryer containing hot
cooking oil or to transfer hot cooking oil from one container to another.
1-2
TRIATHLON SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2.1 Product Description
Dean Triathlon Series gas fryers are energy-efficient, tube-style, gas-fired tabletop units, design­certified by the International Approval Services (AGA/CGA), National Sanitation Foundation (NSF), and manufactured to their basic performance and application specifications.
All units are shipped completely assembled with accessories packed inside the fryer vessel. All units are adjusted, tested and inspected at the factory before shipment.
NOTE: The on-site supervisor is responsible for ensuring that operators are made aware of inherent
dangers of operating a deep fat fryer, particularly aspects of oil filtration, draining, and cleaning of the fryer.
2.2 Principles of Operation
The incoming gas flows through orifices and is mixed with air in the burners to create the correct ratio for proper combustion. The mixture is ignited at the front end of each heat tube by the pilot light. A flame spreader slows the flame as it goes through the burner tube. This slower and more turbulent flame gives much better heat transfer to the walls of the tubes, thereby heating the oil better.
2.3 Rating Plate
The rating plate is found on the right-side panel of the fryer. Information provided includes the model and serial number of the fryer, BTU/hr input of the burners, outlet gas pressure in inches W.C. (mbars) and whether the unit has natural or propane gas orifices.
DANGER
Fryers MUST be connected ONLY to the gas type identified on the attached rating
plate.
2.4 Pre-Installation
A. General: Only a licensed gas fitter should install any gas-fired equipment.
1. A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for safety and ease of future service.
2-1
TRIATHLON SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2.4 Pre-Installation (cont.)
B. Clearances: The fryer area must be kept free and clear of all combustibles. This unit is design-
certified for the following installations:
Commercial installation only (not for household use).
Installation on a non-combustible platform when equipped with factory-supplied 4-inch (10.2 cm) adjustable legs.
Non-combustible construction with no minimum clearance of the sides and rear, and combustible construction with a minimum clearance of 6-inches (15-cm) side and 6-inches (15-cm) rear when equipped with factory-supplied 4-inch (10.2-cm) adjustable legs.
CAUTION
Local building codes usually prohibit a fryer with its open tank of hot oil from being
installed beside an open flame of any type, whether a broiler or the open burner of a
range.
C. Installation Standards:
1. U.S. installations must meet: 2. Canadian installations must meet:
American National Standard Institute CAN 1-B149 Installation Codes ANSI Z83.11 Canadian Gas Association American Gas Association 55 Scarsdale Road 8501 E. Pleasant Valley Road Don Mills, ONT, M3B 2R3 Cleveland, OH 44131
National Electrical Code Canadian Electric Code c22.1, part 1 ANSI/NFPA #70 Canadian Standards Association American National Standard Institute 178 Rexdale Blvd. 1430 Broadway Rexdale, ONT, M9W 1R3 New York, NY 10018
NFPA Standards #96 and #211 National Fire Protection Association 470 Atlantic Avenue Boston, MA 02110
3. CE/EXPORT STANDARDS: Fryer installation must conform with local codes, or in the absence of local codes, to the appropriate national or European Community (CE) standards.
2-2
TRIATHLON SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2.5 Air Supply and Ventilation
Keep the area around the fryer clear to prevent obstruction of combustion and ventilation airflow as well as for service and maintenance.
A. Do not connect this fryer to an exhaust duct.
B. Correct installation and adjustment will ensure adequate airflow to the fryer system.
C. A commercial, heavy-duty fryer must vent its combustion wastes to the outside of the
building. A deep-fat fryer must be installed under a powered exhaust hood, or an exhaust fan must be provided in the wall above the unit, as exhaust gas temperatures are approximately 500-900°F (260-482°C). Check air movement during installation. Strong exhaust fans in the exhaust hood or in the overall air conditioning system can produce slight air drafts in the room.
D. Do not place the fryer’s flue outlet directly into the plenum of the hood, as it will affect the
gas combustion of the fryer.
E. Never store items on shelving over or behind the fryer. Exhaust temperatures can exceed
800°F (427ºC) and may damage or melt items stored near the fryer.
F. Adequate distance must be maintained from the flue outlet of the fryer(s) to the lower edge
of the filter bank. Per NFPA Standards No. 96, a minimum of 18-inches (45-cm) should be maintained between the flue(s) and the lower edge of the exhaust hood filter.
G. Filters and drip troughs should be part of any industrial hood, but consult local codes before
constructing and installing any hood. The duct system, the exhaust hood and the filter bank must be cleaned on a regular basis and kept free of grease.
2.6 Equipment Installed at High Altitudes
A. The fryer input rating (BTU/hr) is for elevations up to 2,000 feet (610-m). For elevations
above 2,000 feet (610-m), the rating should be reduced four percent for each additional 1,000 feet (305-m) above sea level.
B. The correct orifices are installed at the factory if operating altitude is known at time of the
customer’s order.
2-3
TRIATHLON SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2.7 Receiving and Unpacking Equipment
A. Check that the container is upright. Use an outward prying motion - no hammering - to
remove the carton. Unpack the fryer carefully and remove all accessories from the carton. Do not discard or misplace these, as they will be needed.
B. After unpacking, immediately check the equipment for visible signs of shipping damage. If
damage has occurred, contact the carrier and file the appropriate freight claims. Do not contact the factory. Shipping damage responsibility is between the carrier and the dealer.
If your equipment arrives damaged:
1. File claim for damages immediately, regardless of extent of damage.
2. Visible loss or damage: Be sure this is noted on the freight bill or express receipt and is signed by the person making the delivery.
3. Concealed loss or damage: If damage is unnoticed until equipment is unpacked, notify freight company or carrier immediately, and file a concealed damage claim. This should be done within 15 days of date of delivery. Be sure to retain container and all packing materials for inspection.
NOTE: Dean Does Not Assume Responsibility for Damage or Loss Incurred in Transit.
C. Remove all plastic skin from sides, front, and doors of the fryer(s). Failure to do this prior to
initial fryer operation will make the plastic very difficult to remove later.