Frymaster FPD65 Series Operation Manual

FPD65 Series with Built-In Filtration
Frymaster FPD65 Series
Installation & Operation Manual
Gas Fryers
PARTS LIST
PARTS LIST
PARTS LIST PARTS LIST
INCLUDED
INCLUDED
INCLUDEDINCLUDED
24-Hour Service Hotline 1-800-551-8633
MARCH 2004
*8196039*
*8196039*
*8196039**8196039*
Please read all sections of this manual and retain for future reference.
NOTICE
This appliance is intended for professional use only and is to be operated by qualified
personnel only. A Frymaster/Dean Factory Authorized Service Center (FASC) or other qualified
professional should perform installation, maintenance, and repairs. Installation, maintenance,
or repairs by unqualified personnel may void the manufacturer’s warranty. See Chapter 1 of
this manual for definitions of qualified personnel.
NOTICE
This equipment must be installed in accordance with the appropriate national and local codes of
the country and/or region in which the appliance is installed. See NATIONAL CODE
REQUIREMENTS in Chapter 3 of this manual for specifics.
NOTICE
Drawings and photos used in this manual are intended to illustrate operational, cleaning and
technical procedures and may not conform to onsite management operational procedures.
NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
U.S.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: 1) This device may not cause harmful interference, and 2) This device must accept
any interference received, including interference that may cause undesired operation. While
this device is a verified Class A device, it has been shown to meet Class B limits.
CANADA
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set
out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communications du Canada.
NOTICE
IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS
EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED
DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVIC E CENTERS,
AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS
WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE
LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH
ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF
ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
NOTICE The Commonwealth of Massachusetts requires any and all gas products to be installed by a licensed plumber or pipe fitter.
DANGER
Improper installation, adjustment, maintenance or service, and unauthorized alterations or
modifications can cause property damage, injury, or death. Read the installation, operating and
service instructions thoroughly before installing or servicing this equipment. Only qualified
service personnel may convert this appliance to use a gas other than that for which it was
originally configured. See Chapter 1 of this manual for definition of qualified service personnel.
DANGER
Adequate means must be provided to limit the movement of this appliance without depending
upon the gas line connection. Single fryers equipped with legs must be stabilized by installing
anchor straps. All fryers equipped with casters must be stabilized by installing restraining
chains. If a flexible gas line is used, an additional restraining cable must be connected at all
times when the fryer is in use.
DANGER
The front ledge of the fryer is not a step. Do not stand on the fryer. Serious injury can result
from slips or contact with the hot oil.
DANGER
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
DANGER
Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak
must be posted in a prominent location. This information can be obtained from the local gas
company or gas supplier.
DANGER
The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container
at the end of frying operations each day. Some food particles can spontaneously combust if left
soaking in certain shortening material. Additional information can be obtained in the filtration
manual included with the system.
WARNING
No structural material on the fryer should be altered or removed to accommodate placement of
the fryer under a hood. Questions? Call the Frymaster/Dean Service Hotline at 1-800-551-8633.
WARNING
Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is present to seal
the joint between the frypot. Banging fry baskets on the strip to dislodge shortening will distort
the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for
cleaning.
FPD65 Series Gas Fryers
Installation & Operation Manual
TABLE OF CONTENTS
Page #
1. INTRODUCTION 1-1
1.1 After Purchase 1-1
1.2 Ordering Parts 1-1
1.3 Service Information 1-1
1.4 Computer Information 1-1
1.5 Safety Information 1-2
1.6 Service Personnel 1-3
2. IMPORTANT INFORMATION 2-1
2.1 Receiving and Unpacking Equipment 2-1
2.2 General 2-2
2.3 Principles of Operation 2-3
2.4 Rating Plate 2-3
2.5 Pre-Installation 2-3
2.6 Air Supply and Ventilation 2-5
2.7 Equipment Installed at High Altitudes 2-5
3. INSTALLATION 3-1
3.1 Installing the Fryer 3-1
3.2 Gas Connections 3-4
3.3 Adjustments/Adaptation to Different Gases 3-7
3.4 Electrical Connections 3-9
4. FRYER OPERATIONS 4-1
4.1 Initial Start-up 4-1
4.2 Boil-Out Procedure 4-3
4.3 Final Preparation 4-5
FPD65 Series Gas Fryers
Installation & Operation Manual
TABLE OF CONTENTS (CONT.)
Page #
5. FILTRATION OPERATION 5-1
5.1 General 5-1
5.2 Filtration Preparation 5-1
5.3 Daily Filtration Operation 5-4
5.4 Operating the Filter 5-6
6. PREVENTATIVE MAINTENANCE 6-1
6.1 General 6-1
7. TROUBLESHOOTING 7-1
7.1 General 7-1
7.2 Pilot Burner Malfunction 7-2
7.3 Main Burner Malfunctions 7-2
7.4 Wiring Diagram, Main 7-4
7.5 Wiring Diagram, Filter 7-5
8. PARTS LIST 8-1
8.1 Cabinetry and Related Components 8-1
8.2 Doors, Topcaps and Related Components 8-3
8.3 Frypots, Burners and Related Components 8-4
8.4 Component Box Components 8-6
8.5 Filter Pan and Related Components 8-7
8.6 Oil-Drain Components 8-8
8.7 Oil-Return Components 8-10
8.8 Suction Tube, Oil-Return Components 8-11
THIS PAGE INTENTIONALLY LEFT BLANK.
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 1: INTRODUCTION
1.1 After Purchase
In order to improve service, have the following chart filled in by the Frymaster/Dean Authorized Service Technician who installed this equipment.
Authorized Service Technician/FASC Address
Telephone/Fax Model Number Serial Number Gas Type
1.2 Ordering Parts
Customers may order parts directly from their local factory authorized service center. For this address and phone number, contact your factory authorized service center or call the Frymaster/Dean Service Hotline phone number, 1-800-551-8633.
To speed up your order, provide the model number, serial number, gas type, part needed, item part number (if known), and quantity needed.
1.3 Service Information
Call the Frymaster/Dean Service Hotline, 1-800-551-8633, for the location of your nearest factory authorized service center. To assi st you more effi cientl y, alwa ys provide the servic e technici an wit h the model number, gas type, serial number, and the nature of the problem.
1.4 Computer Information
This equipment has been tested and found to co mply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energ y and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.
1-1
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 1: INTRODUCTION
1.4 Computer Information (cont.)
The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions.
The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
1.5 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly.
Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones below.
CAUTION
CAUTION boxes contain information about actions or conditions that may cause or result in a malfunction of your system.
WARNING
WARNING boxes contain information about actions or conditions that may cause or result in damage to your system, and which may cause your system to malfunction.
DANGER
DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage to your system and/or cause your system to malfunction.
1-2
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 1: INTRODUCTION
1.6 Service Personnel
1.6.1 Definitions
A. Qualified and/or Authorized Operating Personnel
1. Qualified/authorized operating personnel are those who have carefull y read the information in this manual and have familiarized themselves with the equipment functions, or have had previous experience with the operation of equipment covered in this manual.
B. Qualified Installation Personnel
1. Qualified installation personnel are individuals, or firms, corporations, or companies, which, either in person or through a representative are engaged in and are responsible for the installation of gas-fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas precautions involved, and have complied with all requirements of applicable national and local codes.
C. Qualified Service Personnel
1. Qualified service personnel are those who are familiar with Frymaster/Dean equipment and have been authorized by Fr ymaster/Dean to perform service on F rymaster/Dean equipment. All authorized service personnel are required to be equipped with a complete set of service parts manuals and stock a minimum amount of parts for Frymaster/Dean equipment. A list of Frymaster/Dean Factor y Authorized S ervice C e nters (FAS Cs ) was incl u ded wi th t he fr yer when shipped from the factory. Failure to use qualified service personnel will void the Frymaster/Dean warranty on your equipment.
1-3
THIS PAGE INTENTIONALLY LEFT BLANK.
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2.1 Receiving and Unpacking Equipment
A. Check that the containers are upright. Use an outward prying motion - no hammering - to
remove the cartons. Unpack fryers carefully and remove all accessories from the carton and/or frypots. Do not discard or misplace accessories, as they will be needed during final assembly and fryer operation.
B. After unpacking, immediately check the equipment for visible signs of shipping damage. If
damage has occurred, contact the carrier and file the appropriate freight claims. Do not contact the factory. Shipping damage responsibility is between the carrier and the dealer.
If your equipment arrives damaged:
1. File claim for damages immediately, regardless of extent of damage.
2. Visible loss or damage: Be sure this is noted on the freight bill or express receipt and is signed by the person making the delivery.
3. Concealed loss or damage: If damage is unnoticed until equipment is unpacked, notify freight company or carrier immediatel y, and file a concealed damage clai m. This should be done within 15 days of date of delivery. Be sure to retain container and all packing materials for inspection.
NOTE: Frymaster/Dean Does Not Assume Responsibility for Damage or Loss Incurred in Transit.
C. Bu ilt-in filtration cabinet: Remove the filter pan from the cabinet before removing system
from pallet.
D. Five- and Six-battery Frying Systems: Units are shipped on two pallets. Casters are pre-
installed on the frying system and unloading ramps are furnished to facilitate removal of the units off the pallets. Remove pallet supports from underneath fryer and carefully roll the unit down the ramps from the front (cooking side). See assembly instructions shipped with unit for system assembly.
E. Remove all plastic skin from sides, front, and doors of the fryers. Units are shipped with
plastic skin to protect the stainless components from surface damage during shipping. Failure to remove the plastic prior to initial fryer operation will make it very difficult to remove later.
2-1
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2.2 General
Qualified, licensed, and/or authorized installation or service personnel only (as defined in Section 1.6) should perform the following:
Installation and service on Frymaster/Dean equipment.
Conversion of this appliance from one gas type to another.
Failure to use qualified, licensed, and/or authorized installation or service personnel to install, convert to another gas type or otherwise service this equipment will void the Frymaster/Dean warranty and may result in damage to the equipment or injury to personnel.
Where conflicts exist betw een instructions and information in this manua l and local code or national codes, or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed.
DANGER
Building codes prohibit a fryer with its open tank of hot oil/shortening from being
installed beside an open flame of any type, including those of broilers and ranges.
Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Receiving and Unpacking Equipment in Section 2.1.)
2.2.1 Product Description
Frymaster FPD65 Series gas fryers are energy efficient, tube-style, gas-fired units. All units are shipped completely assembled with accessories packed inside the fr ypot. Frymaster FPD65 Series gas fryers are adjusted, tested and inspected at the factor y before shipment. The input rates of this model are listed in this manual.
WARNING
The on-site supervisor is responsible for ensuring that operators are made aware of
the inherent hazards of operating a hot oil frying system, particularly the aspects of
system operation, oil filtration, draining and cleaning procedures.
2-2
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2.3 Principles of Operation
The incoming gas flows through orifices and is mixed with air in the burners to create the correct ratio for proper combustion. The mixture is ignited at the front end of each heat tube by the pilot light. Internal diffusers slow the flame as it goes through the burner tube. This slower and more turbulent flame gives much better heat transfer to the walls of the tubes, thereby heating the oil better.
2.4 Rating Plate
This is attached to the inside front door panel. Information provided includes the model and serial number of the fryer, BTU/hr input of the burners, outlet gas pressu re in in ches W .C. and wheth er t he unit has natural or propane gas orifices.
DANGER
Fryers MUST
MUST be connected ONLY to the gas type identified on the attached rating
MUSTMUST
plate.
2.5 Pre-Installation
DANGER
No structural material on the fryer should be altered or removed to accommodate
placement of the fryer under a hood. Questions? Call the Frymaster/Dean Service
Hotline at 1-800-551-8633.
DANGER
Do not connect this appliance to the gas supply before reviewing all information in
this chapter.
A. General: Only licensed personnel should install any gas-fired equipment.
1. A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for safety and ease of future service.
2. Frymaster FPD65 Series gas fryers require 120VAC 60 c ycle or 230VAC single-phase 50­hertz (International/CE) electrical service and are equipped with a 16-3 SJT grounded flexible power cord for a dire ct connection to the power supply. Amperage draw for each unit depends on the accessories supplied with the unit/system.
2-3
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2.5 Pre-Installation (cont.)
B. Clearances: The fryer area must be kept free and clear of all combustibles. This unit is design-
certified for the following installations:
1. Commercial installation only (not for household use).
2. Non-combustible floor installation equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch (13-cm) casters;
3. Combustible construction with a minimum clearance of 6-inches (15-cm) side and 6-inches (15-cm) rear, and equipped with factory-supplied 5-inch (13-cm) casters.
C. Installation Standards
1. U.S. installations must meet: 2. Canadian installations must meet:
American National Standard Institute CAN 1-B149 Installation Codes ANSI Z83.11 Canadian Gas Association American Gas Association 55 Scarsdale Road 8501 E. Pleasant Valley Road Don Mills, ONT, M3B 2R3 Cleveland, OH 44131
National Electrical Code Canadian Electric Code c22.1, part 1 ANSI/NFPA #70 Canadian Standards Association American National Standard Institute 178 Rexdale Blvd. 1430 Broadway Rexdale, ONT, M9W 1R3 New York, NY 10018
NFPA Standards #96 and #211 National Fire Protection Association 470 Atlantic Avenue Boston, MA 02110
2-4
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2.6 Air Supply and Ventilation
DANGER
This appliance must be installed with sufficient ventilation to prevent the occurrence
of unacceptable concentrations of substances harmful to the health of personnel in
the room in which it is installed.
Keep the area around the fryer clear to prevent obstruction of combustion and ventilation airflow as well as for service and maintenance.
A. Do not connect this fryer to an exhaust duct.
B. Correct installation and adjustment will ensure adequate airflow to the fryer system.
C. A commercial, heavy-duty fryer must vent its combustion wastes to the outside of the
building. A deep-fat fryer must be installed under a powered exhaust hood, or an exhaust fan must be provided in the wall above the unit, as exhaust gas temperatures are approximately 800-1000°F (427-538°C). Check air movement during installation. Strong exhaust fans in the exhaust hood or in the overall air conditioning system can produce slight air drafts in the room.
D. Do not place the fryer’s flue outlet directly into the plenum of the hood, as it will affect the
gas combustion of the fryer.
E. Never use the interior of the fryer cabinet for storage or store items on shelving over or
behind the fryer. Exhaust temperatures can exceed 800°F (427°C) and may damage or melt items stored in or near the fryer.
F. Adequate distance must be maintained from the flue outlet of the fryer(s) to the lower edge
of the filter bank. Per NFPA Standards No. 96, a minimum of 18-inches (45-cm) should be maintained between the flue(s) and the lower edge of the exhaust hood filter.
G. Filters and drip troughs should be part of any industrial hood, but consult local codes before
constructing and installing any hood. The duct system, the exhaust hood and the filter bank must be cleaned on a regular basis and kept free of grease.
2.7 Equipment Installed at High Altitudes
A. The fryer input rating (BTU/hr) is for elevations up to 2,000 feet (610- m). For elevations
above 2,000 feet (610-m), the rating should be reduced four percent for each additional 1,000 feet (305-m) above sea level.
B. The correct orifices are installed at the factory if operating altitude is known at time of the
customer’s order.
2-5
THIS PAGE INTENTIONALLY LEFT BLANK.
FRYMASTER FPD65 SERIES GAS FRYERS
r
CHAPTER 3: INSTALLATION
3.1 Installing the Fryer
Decathlon 65 Series fr yer systems are shipped in sections. The fryers are uncrated, removed from pallets and assembled together. Important aspect s during assembly include ali gning and connecting the drain system, oil return system, rinse-line system (where applicable), oil-return switch wiring harness and fryer cabinets. Slight modifications to connecting hardware may be required when assembling the system. The instructions below provide step-by-step instructions to assist the installer in assembly. For this procedure, the fryers are numbered from right to left as follows: Fryers #1, #2, #3, #4, #5 and #6 (where applicable).
1. Open the doors of the filtration fryer cabinet.
Remove filter pan from the cabinet. Uncrate fryers and remove the pallet supports. Install ramps and slowly roll the fryer(s) off the pallets.
2. Remove door from fryers to be connected by
lifting the door upward and removing the door pin from the bottom hinge. Remove slip-nuts from drain-tees on fryers being connected, lubricate O-rings with vegetable oil and install on drainpipe (Fig. 2). Use care not to dam age
the slip-nut O-rings when installing slip-nut on drainpipe. Insert the drainpipe into the fryer
drain-tee (Fig. 3). Screw slip-nut onto the tee but do not tighten at this time. Position fryers being connected within 6 inches of each other, near the permanent installation area. Guide the drainpipe through the opposite fryer cabinet opening as the cabinets are positioned.
NOTE: When the slip nuts are tightened, the "blue" marks on each end of the drainpipe should align to the outside edge of each slip nut.
Figure 1. Remove pallet supports (arrow) before removing fryers from pallets.
Properly align the dr ai npi pe evenly between the
two drain-tees using t he "bl ue " m arks on the tube
ends to prevent leaks an d/or blocked drain
Figure 2. Slip-nut/drainpip e detai l.
valves.
Figure 3. Insert drainpipe section int o fryer drain-tee before pushing fryers togethe (arrow). Do this as required f or all cabinets being assembled.
3-1
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 3: INSTALLATION
3.1 Installing the Fryer (cont.)
3. Connect red/white or red/yellow wires (Figure 4, left) between fryer sections being assembled (Figure 4, right, arrow). Oil-return will not operate properly if these wires are not connected.
NOTE: On systems shipped in three or more sections, additional wiring between cabinets will exist. Ensure all wires are connected before completing cabinet assembly.
4. Remove the lower back panel-strips on fryers being assembled to gain access to the oil return and rinse-line connections (Figure 5, arrows). Back removal may not be required on some systems.
5. Slowly push the two cabinets together. Ensure the drainpipe and slip-nut are aligned with the drain-tee on the opposite fryer section. Ensure the oil-return and rinse-hose connections (where applicable) on each fryer section are aligned. Ensure oil-return switch wires between cabinet sections are not pinched when the cabinets are brought together. Pull excess wire through the opposite fryer side as the cabinets are brought together. Secure excess wire inside cabinet with a wire tie.
6. With the cabinets together, insert the drainpipe
into the opposite fryer drain-tee and position it evenly between the fryers being connected. Connect the oil-return and rinse-lines by accessing the oil return union through the lower fryer-back openings. Connect all fittings, but do not tighten at this time.
7. Align the cabinet connection holes, front and back (Figure 6, arrow). Connection hardware is included in the accessories pack. Insert bolts and install nuts, but do not tighten. If holes do not align, use a 3/16" drill-bit and drill through the misaligned hole.
8. Install the frypot joiner strip between cabinet sections (Figure 7; also see factory-installed strips on two-battery cabinet sections).
Figure 4. Oil return wires between sections must be connected for oil-return operation.
Figure 5. Oil return and rinse-line (where applicable) connections.
Figure 6. Cabinet connection locations inside cabinet sections (front shown).
3-2
Figure 7. Install joiner strip(s) after fryers are connected.
FRYMASTER FPD65 SERIES GAS FRYERS
y
CHAPTER 3: INSTALLATION
3.1 Installing the Fryer (cont.)
9. Install the front connecting post on the connected
cabinets (Figure 8; see factory-installed posts on two-battery fryer sections).
10. Complete installation of topcap battering strips
after the front connecting post has been installed (Figure 9).
NOTE: Systems shipped in three or more sections will require the installation of topcaps and other components prior to installing topcap-battering strips. See Topcap Installation Instructions for these systems.
11. Install the rear connecting plate (Figure 10).
Remove four screws from the cabinet backs (Figure 10, arrows), install connecting plate and replace screws. Connection strips vary from system to system.
12. At the fryer front: Tighten the drain manifold
slip-nuts. Install doors removed at the beginning of assembly. At the fryer back: Tighten the oil­return line and rinse-line (where applicable) union(s).
13. Reinstall filter pan after fryer start-up has been
performed (boil-out, burner adjustment, etc.)
NEVER ALLOW WATER OR BOILOUT SOLUTION INTO FILTER SYSTEM.
Check all connections for leaks. components operate properly.
Ensure all
Figure 8. Installing fr ont connecting post on connected fryer sections.
Figure 9. Complete insta llation of topc ap battering strips (arrow) after installing front connecting post(s) on connected fr
ers.
Figure 10. Install rear connecting plate.
3-3
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 3: INSTALLATION
3.1 Installing the Fryer (cont.)
DANGER
Fryers must be at room temperature and empty of oil during movement to avoid
damage and possible bodily injury.
DANGER
Hot shortening can cause severe burns. Avoid contact. Under all circumstances, oil
must be removed from the fryer before attempting to move it to avoid oil spills, and
the falls and severe burns that could occur. This fryer may tip and cause personal
injury if not secured in a stationary position.
3.2 Gas Connections
DANGER
Before connecting new pipe to this appliance the pipe must be blown out thoroughly
to remove all foreign material. Foreign material in the burner and gas controls will
cause improper and dangerous operation.
NATIONAL CODE REQUIREMENTS
This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration.
This equipment is manufactured t o use the type of gas specified on the rating plate attached to the door. Connect equipment stamped "NAT" only to natural gas and that stamped "PRO" only to LP (Propane) gas.
Notice
Installation shall be made with a gas connector that complies with national and local codes.
Quick disconnect devices, if used, shall likewise comply with national and local codes.
The fryer MUST
MUST be connected to the gas supply specified on the rating and serial
MUSTMUST
DANGER
number plate located on the back of the fryer door.
3-4