Friedrich VHA24K75SPH, VHA24K50SPH, VHA24K34SPH, VHA24K25SPH, VHA24K25RTH Owner’s Manual

...
Vert-I-Pak®
SinglePackageVerticalAirCenditieningSystem
A-Series 24,000 BTU/h
Installation& OperationManual
920-159-01 (10-03)
920-159-01(10-03)
TableofContents
L GeneralSpecifications
ModelNumberIdentificationGuide................................................................................................................................... 4
VERT-I-PAKChassisSpecifications ................................................................................................................................... 4
II. Installation
1. UtilityClosetDimensions................................................................................................................................................... 5
2. WallPlenum & ArchitecturalLouverInstallation................................................................................................................ 6
3. ElectricalInformation..................................................................................................................................................... 7-9
4. Indoor ReturnAirGrilleInstallation .................................................................................................................................. 10
5. DuctworkPreparationandCFM ....................................................................................................................................... 11
6. ChassisInstallation.......................................................................................................................................................... 11
7. ChassisFinalConnections(Electrical,Duct, Drain& WallThermostat)............................................................................ 12
8. FinalInstallationChecklist............................................................................................................................................... 12
III.
IV.
V. Vert-I-PakAccessories.................................................................................................................................................... 15
ChassisOperation
9. ThermostatControl.......................................................................................................................................................... 12
10. LowAmbientProtectionfor Compressor & Fan................................................................................................................ 12
11. HeatingDefrost(Heat PumpModelsonly)........................................................................................................................ 12
12. FreshAirDoor................................................................................................................................................................... 13
13. CondensateDisposalSystem .......................................................................................................................................... 13
Service,Maintenance&Warranty
14. Servicing/Chassis QuickChangeouts............................................................................................................................. 13
15. RoutineMaintenance....................................................................................................................................................... 13
16. Warranty.......................................................................................................................................................................... 14
Please read this manual thoroughly prior to equipment installation or operation. It is the installer's responsibility to properly apply and installthe equipment. Installation must be inconformance with
the NFPA 70-2002 National Electric Code or current edition and Universal Mechanical Code current edition and applicable local or national codes.
Proper installation is not difficult but it is essential.
920-159-01 (10-03)
Vert-I-Pak Installation Recommendations
Forproperunitperformanceandmaximumoperatinglifepleaserefertotheminimuminstallationclearancesbelow.
FigureI
VERT-I-PAK ®units must be installed on an outside wall. Confined spaces and/or covered areas should be avoided. Units should be installed no closer than 12" apart when two units are side by side. If three of more
units are to operate next to one another allow a minimum of 60" between units or pairs of units. Also, a vertical clearance of 60" should be maintained between units. Units installed on the bottom floor should be mounted
at least 6" off of the ground.
SMALL RECESS OK
60"_
60"_
6_ _ h_
6" J
Figure2
Any time obstructions are present use the following guidelines for proper
spacing from the VERT-I-PAK louver:
For minor obstructions such as lamp poles or small shrubbery a clearance
of 24" from the outdoor louver should be maintained.
For major obstructions such as a solid fence, wall or other heatrejecting device like a condensing unit, a mini- mum distance of 72" should be kept.
60" 60"
D D D D D D
D D
D D D
_A_
LARGER RECESS OK iF A> 5xB
\
D
6o'_
D
60'_
D D
BUILDING
OUTDOOR - 72"
UNiT
MAJOR OBSTRUCTION
FENCE
H
12"
The above suggestions are for reference only and do not represent all possible installations. Please contact the factory for information regarding affects of other installation arrangements.
By following these simple recommendations you can be ®
confident that your Friedrich Vert-I-Pak will provide years
of worry-free operation.
3
920-159-01 (10-03)
Section I. GeneralSpecifications
MODEL NUMBER
SERIES
V=Vertical Series
E=Cooling with or without electric heat H=Heat Pump
DESIGN SERIES
A = 32" and 47" Cabinet
NOMINAL CAPACITY A-Series (Btu/h)
09 = 9,000
12 = 12,000 18 = 18,000
24 = 24,000 VOLTAGE
K = 208/230V-1Ph-60Hz
MODEL:
Voltage (V)
Refrigerant Chassis Width
Chassis Depth Chassis Height **
Supply Duct Collar*** Drain Connection
Min. Circuit Amps CFM Indoor
Max. Duct ESP
V A
L ENGINEERING CODE
OPTIONS RT = Standard Remote Operation
SP = Seacoast Protected
ELECTRIC HEATER SIZE
A-Series
00 = No electric heat 25 = 2.5 KW
34 = 3.4 KW
50 = 5.0 KW 75 = 7.5 KW
10= 10KW
V(E,H)A24
230/208
R-22
23.125
23.125
47.25 10"
3/4" FPT
See Nameplate
See chart, pg. 11
,4 in, water
NOTES:
** Height includes 2" ductcollar & isolators under unit. *** Factory collar accepts 10" flex duct.
920-159-01 (10-03)
II. Installation
1) UtilityClosetDimensions
Recommended utility closet dimensions and atypical indoorinstallation are illustratedin Figure 1. Three inchesminimum clearance on
three sides of the unit must be allowed for return airflow, installationaccess and service access. See Figures 1& 2 for clearances and reference dimensions.
Figure 3
Field-supplied Filter (25" x20")
VPRG4 Access Panel & Return Air Filter Grille
TypicalUtility Closet
j.'J!
POWE Disconnect
3" Clearance on ell
three sides
minimum for
Chassis Shown in Closet, on Optional Platform
Rigid Ductwork
t/1-14 Wall Plenum
Chassis is beneath unit is shipped with required on all
vibration VEA/VHA24 units. isolators Drain pen must be installed installed prior to
drain pan
chassis installaiion
Figure4 TopView
22.3
8.4
-- electrical II -- I 6.2 entrance
Vert-l-Pak Chassis2-ton dimensions: 23" wide x 23" deep x 47 1/4" high.
R
VPAWP1-8/1-14 Wall Plenumcut-out dimensions 24 5/8" wide x 30 7/8" high.
VPRG4 Access Panel cutout dimensions: 27" wide by 55 3/4" high.
See Figure 8 (Page 10) for proper chassis installation.
4.2
NOTE: Drain panmust beinstalled in closet prior to chassis insertion intoplenum. See Figure7 (page8) for drain pan
installationdetails.
5