Friedrich WE12C33D, US12D30B, WS10C30D, WS08C10D, US10D30B Brochure

...
THRU-THE-WALL
AIR CONDITIONERS
COMMERCIAL AND RESIDENTIAL GRADE
THE EXPERTS IN ROOM AIR CONDITIONING
WHEN SHOULD YOU INSTALL A SOLID SIDE SLEEVE?
A solid-side wall sleeve allows for installation in thick exterior walls where the installation of room air units with side vents would affect performance and may even void
the warranty.
ROOM AIR CONDITIONER
Blocked side vents restrict air ow.
FRIEDRICH THRU-THE-WALL
Solid-side sleeve (no side vents) can be installed in thicker walls. Sleeve can be positioned ush with exterior
wall.
Sleeve size
Applications
OVERVIEW
Perfect t for Fedder’s 27” sleeves Y
Top-mounted controls Y
Electronic controls Y Y
Programmable timer 24 hr. 24 hr.
Remote control Y Y
Auto-restart when power is
interrupted
Smart Fan auto adjusting fan Y
Upward angled air discharge Y
COMFORT & CONVENIENCE
Air ow direction control 4-way 6-way
Fan speeds 3 3
THRU-THE-WALL MODELS
WallMaster
Fits 27” sleeves Fits sleeves from
RESIDENTIAL OR
LIGHT COMMERCIAL
24 1/2” to 27”
RESIDENTIAL OR
LIGHT COMMERCIAL
Y Y
Uni-Fit
THRU-THE-WALL AIR CONDITIONERS
WallMaster®. A perfect fit in Friedrich and competitor’s 27” sleeves.
Commercial grade quality unit is ideal for installation in new construction, retrots and remodels.
Perfect t in 27"
wall sleeves,
including Fedders A and B* sleeves.
FITS SLEEVES
16 3/4" HIGH X 27" WIDE
WallMaster®
8000-15600 Btu
Up to 10.4 EER
WallMaster
Electric Heat
COOLING
9800-15600 Btu
Up to 9.8 EER
ELECTRIC HEAT
9100-11000 Btu
WallMaster
Heat Pump
COOLING
9000-12000 Btu
Up to 9.8 EER
HEATING
7500-9350 Btu
Up to 2.6 COP
®
®
Or with minimum intrusion into the room.
Steel inner wall and extra dense
insulation
Vibration-isolating design and
components
TECHNOLOGY
Superior airflow design Y
SOUND REDUCTION
®
ENERGY STAR
Environmentally friendly R-410A Y Y
EARTH
FRIENDLY
Energy saver switch Y Y
Washable, antimicrobial air lter Y Y
HEALTH
Stale air exhaust Y
EntryGard™ anti-intrusion
protection
Insect barrier Y
SAFETY
Slideout chassis Y Y
Power cord direction Left Right
Concealed power cord option Y
Internal drain kit option Y
Bafe adapter kit (for installation in
INSTALLATION
Fedders ‘B’ sleeves)
Condensate drain kit Y
models Y Y
Y Steel inner wall
Y Y
Y
Y
COOL
Select MODE, FAN SPEED, MONEY SAVER
TEMPERATURE and set the
TIMER.
NOTE: Chassis requires WSE sleeve for new installations (sold and shipped separately)
®
, adjust
COOL & HEAT
WSE wall sleeve ships with weather panels and grille.
Sleeve is shown at right with
standard galvanized steel inner panel, painted steel outer panel and standard
grille
Fits Fedders A & B sleeves. *B sleeve installations require BAK accessory, bafe adapter kit.
Inner steel weather panel WSE sleeve Outer weather panel Standard grille
2
3
WALLMASTER® FEATURES
THRU-THE-WALL AIR CONDITIONERS
Comfort & Convenience
• Easy-to-reach, top mount controls
• Remote control
• 24-hour timer
• Smart Fan auto-adjusts fan speed to maintain desired temperature
• Check lter reminder
• 3-speed fan
• Auto restart
• Electronic defrost control
• Reversible louver allows a second airow option
Energy Management
• Money Saver® setting saves money by operating the fan only when
needed
• ENERGY STAR
• R-410A refrigerant
®
qualied models
Health and IAQ
• Washable, antimicrobial lter
Durability & Quality
• Rotary compressors provide quiet, dependable performance
• Premium aluminum exterior grille
• Dense blower insulation
• Ried copper tubing
• Impact resistant front cover
• High tech ns with sine wave lanced louvers increase energy efciency
by increasing surface area for heat
exchange
Ried copper
tubing
Sine wave
lanced louvers
Safety & Security
• EntryGard™ anti-intrusion protection secures chassis to sleeve to deter ‘kick­in’ intrusion
• Power cord current leakage protected
• Insect barrier
Installation Features
• Mounts ush with the exterior wall
for a neat appearance
• Ideal for thicker wall installations, where side ns don’t t
• Reversible louver allows for a second airow option
• A high efciency replacement for 27” sleeves including Fedders A and B*. Sleeve measures 27” W x 16 3/4” H
Accessories
• WSE sleeve, ships with inside and outside weather panel and standard
grille
• AG architectural grille for use with WSE sleeve
• Bafe adapter kit for use with deep
sleeve installations
• Drain kit for condensate disposal
• Internal drain kit for new
construction applications where
condensate drain system is built-in
Uni-Fit® Universal fit for easy replacement in existing 24 1/2˝, 26” or 27” sleeves.
Residential grade quality for installation in new construction, retrots and remodels.
FITS SLEEVES
24 1/2", 26" AND 27" WIDE
Uni-Fit
®
8000-13000 Btu
Up to 9.8 EER
Uni-Fit
®
Electric Heat
COOLING
8000-11500 Btu
Up to 9.6 EER
ELECTRIC HEAT
3850-11200 Btu
Angled air discharge for superior air distribution when the unit is installed
low on a wall. Reversible louver for a
second air ow option.
Sleeve can be installed ush with the exterior wall. Optional AG
architectural grille shown.
WallMaster® fits existing Fedders sleeves.
Sleeve Dimensions
Height (inches) 16 3/4 16 3/4 16 3/4
Width (inches) 27 27 27
Depth (inches) 16 3/4 16 3/4 19 3/4
Friedrich
WSE Sleeve
Fedders A Sleeve
Fedders
B Sleeve*
Select MODE, FAN SPEED, MONEY SAVER
TEMPERATURE and set the
TIMER.
®
, adjust
USC wall sleeve ships with weather panels and grille.
Sleeve is shown at right with
standard painted steel inner panel, painted steel outer panel and standard grille
COOL
Inner weather panel USC sleeve Outer weather panel Standard grille
COOL & HEAT
Chassis requires WSE sleeve (sold and shipped separately) *Installation in Fedders B sleeve requires a bafe kit. See BAK accessory under accessories.
4
NOTE: Chassis requires USC sleeve for new installations (sold and shipped separately)
5
Model Height Widt h Depth
Depth
with
Front
Minimum Extension Into Room
Minimum
Exten-
sion
Outside
Thru-the-wall
Finished Hole
Height Width Max. Depth
WallMaster
®
WSE Sleeve 16 3/4" 27" 16 3/4" 23" 7 1/2" 9/16" 17 1/4" 27 1/4" 15 5/16"
Chassis 15 3/4" 26 1/2" 21" 22”
Uni-Fit
®
USC Sleeve 15 1/2" 25 7/8" 16 3/4" 20 1/2" 1/2" 15 3/4" 26 1/8" 16 1/4"
US Chassis 14 3/ 8" 24" 18 1/ 2” 20 1/8" 3 3/4"
UE Chassis 14 3/8" 24 5/8" 18” 19 5/8" 3 1/2"
UNI-FIT® FEATURES
THRU-THE-WALL OPTIONAL ACCESSORIES
Comfort & Convenience
• 6-way air ow control
• Remote control
• 24-hour timer
• Check lter reminder
• 3-speed fan
• Auto restart
• Defrost control
Energy Management
• Money Saver® setting saves money by conserving energy
• ENERGY STAR
®
qualied models
• R-410A refrigerant
Health and IAQ
• Washable antimicrobial lter
• Stale air exhaust
Durability & Quality
• Rotary compressors provide quiet, dependable performance
• Seacoast protection for corrosion resistance in harsh environments
Installation Features
• Universal t trim ring
• Chassis designed to t 24 ½” to 27”
sleeves
• USC sleeve ts standard 26” sleeve
opening. See installation manual for
exact dimensions.
Accessories
• USC sleeve ships with expanded
aluminum grille
• Replacement grille ships with US/
UE chassis for use in existing sleeves when a grille is needed
• UXAA architectural grille for use with USC sleeve
WallMaster® 27” Sleeve Exterior Grilles
WSE SLEEVE
Standard Grille Premium, stamped steel grille with powder coat paint. Ships with sleeve. Galvanized steel inner and outer weather panels
also ship with sleeve.
WSE SLEEVE Optional Architectural Grille- AG
Premium brushed aluminum
grille.
Installation Accessories (27” sleeve models only)
DK / Drain Kit Installed at the back of the unit and allows for attachment to condensate disposal system, if necessary or desired.
IDK / Internal Drain Kit
New construction applications
where a condensate drain system
has been built into the wall interior.
IMPORTANT:
Operating the air conditioner
with incorrect rear grille or
without Bafe Adapter Kit (on 19 3/4” deep sleeve) will recirculate discharge air and cause compressor overload
to trip. This will cause the unit to shut
down temporarily and may lead to premature compressor
failure.
BAK / Bafe Adapter Kit
Necessary when installing in a
sleeve deeper than 16 3/4" deep, such as Fedders B sleeve (19 3/4" deep).
CORRECT Vertical Louvers
INCORRECT Horizontal Louvers
Trim ring
IMPORTANT: 1” gap on sides and 1/2”
gap at top, which allows installation into
varying sleeve sizes, can be covered by two-piece trim ring that ts over the chassis front. Trim ring comes standard
with chassis.
NEW!
UXAA- Architectural grille for USC sleeve
Uni-Fit® installs in many existing sleeves.
Carrier
(51S
Series)
Sleeve Dimensions
Height
(inches)
Width
(inches)
Depth
(inches)
NOTE: Chassis requires USC sleeve for new installations (sold and shipped separately)
6
Friedrich
USC Sleeve Amana
15 1/2 15 5/8 16 7/8 16 3/4 15 3/4 15 5/8 16 1/2 15 1/4
25 7/8 26 25 3/4 27 26 3/4 26 25 7/8 25 1/2
16 3/4 16 7/8 18 5/8 16 3/4 or 19 3/4 15 16 7/8 17 1/8 or 23 16, 17 1/2 or 22
Friedrich WSE
Fedders/
Emerson/
Emer-
son/
Fedders
GE/
Hot-
point Whirlpool
White-Westinghouse/
Frigidaire/ Carrier (52F
Series)
Uni-Fit® 26” Sleeve Exterior Grilles
Optional Architectural Grille UXAAUSC Sleeve Standard Grille
Sleeve/Chassis Dimensions
STANDARD GRILLE – Ships with USC sleeve
Expanded aluminum grille designed for use with USC sleeve.
REPLACEMENT GRILLE – Ships with US/UE chassis
Black plastic for use on existing sleeves without any grille.
IMPORTANT:
When installing into an existing sleeve, consult Installation Section of your Installation/Operation Manual to determine whether or not the grille needs to be replaced and/or a bafe adapter should be used.
Trim ring
IMPORTANT:
US= 3 3/8”, UE= 2 7/8
US chassis w/front fully installed into USC sleeve extends into room 3 3/8”. UE chassis w/front fully installed into USC sleeve extends into room 2 7/8”. 1” gap on sides and
1
/2” gap at top can be covered by two-piece trim ring that
ts over the chassis front
7
SPECIFICATIONS
Energy
Estar
Model Cooling Btu Heating Btu
WALLMASTER
Cool only
WS08C10D 8000 - 115 6.4 769 - - 10.4
WS10C10D 9700 - 115 8.2 990 - - 9.8 $89 - 2.4 260 WSE 103 107
WS12C10D 11500 - 115 11.5 1174 - - 9.8 $106 - 3.1 295 WSE 112 116
WS10C30D 10000/9800 - 230/208 4.5/4.9 1020/1000 - - 9.8/9.8 $92 - 1.5 260 WSE 101 105
WS12C30D 11500/11200 - 230/208 5.5/6.0 1174/1143 - - 9.8/9.8 $106 - 3.0 290 WSE 109 113
WS16C30 15600/15000 - 230/208 8.3/8.9 1835/1765 - - 8.5/8.5 $165 - 4.2 290 WSE 119 123
Heat Pump
WY09C33D 9300/9000 7500/7500 230/208 4.3/4.6 949/918 3.9/4.1 833/833 9.8/9.8 $85 2.6/2.6 2.1 260 WSE 103 107
WY12C33 12000/11800 9350/9200 230/208 6.1/6.4 1395/1372 4.8/5.1 1062/1010 8.6/8.6 $126 2.5/2.6 2.6 275 WSE 111 115
Cool with Electric Heat
WE10C33D 10000/9800 11000/9100 230/208 4.5/4.9 1020/1000 16.0/14.7 3550/2950 9.8/9.8 $92 - 1.5 260 WSE 104 108
WE12C33D 11500/11200 11000/9100 230/208 5.5/6.0 1174/1143 16.0/14.7 3550/2950 9.8/9.8 $106 - 3.0 290 WSE 107 111
WE16C33 15600/15000 11000/9100 230/208 8.3/8.9 1835/1765 16.0/14.7 3550/2950 8.5/8.5 $165 - 4.2 290 WSE 119 123
UNI-FIT
Cool Only
US08D10B 8000 - 115 7.4 810 - - 9.8 $73 - 2.2 260 USC 73 79
US10D10B 9800 - 115 9.2 1000 - - 9.8 $90 - 3.2 260 USC 78 84
US12D10B 11500 - 115 10.7 1170 - - 9.8 $106 - 3.8 TBD USC 80 87
US10D30B 10000/9800 - 230/208 4.7/5.1 1020/1000 - - 9.8/9.8 $92 - 3.2 285 USC 78 86
US12D30B 11500/11200 - 230/208 5.4/5.8 1170/1140 - - 9.8/9.8 $106 - 3.8 260 USC 80 87
US14D30B 13000/12600 - 230/208 7.0/7.5 1530/1480 - - 8.5/8.5 $138 - 4.0 310 USC 87 94
Cool with Electric Heat
UE08D11B 8000 3850 115 7.5 830 10.7 1230 9.6 $77 - 2.2 260 USC 73 79
UE10D33B 10000/9800 11200/9200 230/208 4.7/5.2 1060/1040 15.3/14.0 3500/2900 9.4/9.4 $96 - 3.2 285 USC 78 84
UE12D33B 11500/11200 11200/9200 230/208 5.6/6.0 1220/1190 15.3/14.0 3500/2900 9.4/9.4 $110 - 3.8 290 USC 80 87
®
®
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
Efciency
Ratio
EER
Estimated
Yearly
Energy
Cost COP
$69
Moisture Removal Pints/HR CFM Sleeve
- 1.2 250 WSE 93 97
ENERGY STAR® models
Weight
WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red) indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
WALLMASTER HEAT PUMP
HEATING PERFORMANCE: Cha nge-over fro m heat pump operati on to resistanc e operation on models indicated is automatic at a preset outside ambient temperature of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does not exceed the resistance heating capacity rating of the unit, the heating perfor­mance will be satisfactory.
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature) and terminated at 43°F (outdoor coil temperature). During defrost, the compressor stops and the electric heat starts, then operates with the fan to maintain indoor comfort. Below 43°F, the unit remains in electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent condensate from freezing inside drain pan.
Note: all models will produce condensate. If condensate disposal is desired, an optional drain kit is available.
Net
Lbs.
Ship
Weight
Lbs
Plug Face/ Circuit Rating
Circuit
WallMaster
®
Model Number
WS08C10D, WS10C10D, WS12 C10D
WS10C30D, W S12C30D, WS16 C3 0
WE10C33D, WE12C33D, WE16C33, WY09C 33D, WY12C3 3
®
Uni-Fit Model Number
US08D10B, UE08D11B US10D10B, US12D10B
US10D30B, US12D30B, US14D30B
Rating
Breaker
or T-D Fuse
125V - 15A 5 - 15P 6
250V - 15A 6 - 15P 6
UE10D33B, UE12D33B 250V - 20A 6 - 20P 6
Plug
Face
(NEMA#)
Power cords are located on front left of WallMaster models and on front right of Uni-Fit models.
Due to continuing research in new energy-saving technology, specications are subject to change without notic e.
ENERGY STAR
As an models meet the
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR®
ENERGY STAR
®
guidelines for energy efciency.
Power
Cord
Length
(ft.)
Wall
Outlet
Appearance
Model
WallMaster
WSE Sleeve 18" 27 1/4" 18"
Chassis 18 1/2" 30 1/2" 29"
®
Uni-Fit
USC Sleeve 17 7/8" 28" 19 1/4"
US Chassis 17 1/4" 27 3/4" 22 1/4”
UE Chassis 17 1/4" 27 3/4” 22 1/4”
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh. For more information, visit www.ftc.gov/energy.
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 www.friedrich.com
Commercial_Thru-the-wall_Air_Conditioners_Brochure_2014 Printed in USA
Carton Dimensions
Height Widt h Depth
®
INCHES
Loading...