A solid-side wall sleeve allows for
installation in thick exterior walls where the
installation of room air units with side vents
would affect performance and may even void
the warranty.
ROOM AIR CONDITIONER
Blocked side vents restrict air ow.
FRIEDRICH THRU-THE-WALL
Solid-side sleeve (no side vents) can
be installed in thicker walls. Sleeve
can be positioned ush with exterior
wall.
Sleeve size
Applications
OVERVIEW
Perfect t for Fedder’s 27” sleevesY—
Top-mounted controlsY—
Electronic controlsYY
Programmable timer24 hr.24 hr.
Remote controlYY
Auto-restart when power is
interrupted
Smart Fan auto adjusting fanY—
Upward angled air dischargeY—
COMFORT & CONVENIENCE
Air ow direction control4-way6-way
Fan speeds33
THRU-THE-WALL MODELS
WallMaster
Fits 27” sleevesFits sleeves from
RESIDENTIAL OR
LIGHT COMMERCIAL
®
24 1/2” to 27”
RESIDENTIAL OR
LIGHT COMMERCIAL
Y Y
Uni-Fit
®
THRU-THE-WALL AIR CONDITIONERS
WallMaster®. A perfect fit in Friedrich and competitor’s
27” sleeves.
Commercial grade quality unit is ideal for installation in new
construction, retrots and remodels.
Perfect t in 27"
wall sleeves,
including Fedders A
and B* sleeves.
FITS SLEEVES
16 3/4" HIGH X 27" WIDE
WallMaster®
8000-15600 Btu
Up to 10.4 EER
WallMaster
Electric Heat
COOLING
9800-15600 Btu
Up to 9.8 EER
ELECTRIC HEAT
9100-11000 Btu
WallMaster
Heat Pump
COOLING
9000-12000 Btu
Up to 9.8 EER
HEATING
7500-9350 Btu
Up to 2.6 COP
®
®
Or with minimum intrusion into the
room.
Steel inner wall and extra dense
insulation
Vibration-isolating design and
components
TECHNOLOGY
Superior airflow designY—
SOUND REDUCTION
®
ENERGY STAR
Environmentally friendly R-410AYY
EARTH
FRIENDLY
Energy saver switchYY
Washable, antimicrobial air lterYY
HEALTH
Stale air exhaust—Y
EntryGard™ anti-intrusion
protection
Insect barrierY—
SAFETY
Slideout chassisYY
Power cord directionLeftRight
Concealed power cord optionY—
Internal drain kit optionY—
Bafe adapter kit (for installation in
INSTALLATION
Fedders ‘B’ sleeves)
Condensate drain kitY—
modelsYY
YSteel inner wall
YY
Y—
Y—
COOL
Select MODE, FAN SPEED,
MONEY SAVER
TEMPERATURE and set the
TIMER.
NOTE: Chassis requires WSE sleeve for new installations (sold and shipped separately)
®
, adjust
COOL & HEAT
WSE wall sleeve ships
with weather panels
and grille.
Sleeve is shown at right with
standard galvanized steel
inner panel, painted steel
outer panel and standard
grille
Fits Fedders A & B sleeves. *B sleeve installations require BAK accessory, bafe adapter kit.
• Money Saver® setting saves money
by conserving energy
• ENERGY STAR
®
qualied models
• R-410A refrigerant
Health and IAQ
• Washable antimicrobial lter
• Stale air exhaust
Durability & Quality
• Rotary compressors provide quiet,
dependable performance
• Seacoast protection for corrosion
resistance in harsh environments
Installation Features
• Universal t trim ring
• Chassis designed to t 24 ½” to 27”
sleeves
• USC sleeve ts standard 26” sleeve
opening. See installation manual for
exact dimensions.
Accessories
• USC sleeve ships with expanded
aluminum grille
• Replacement grille ships with US/
UE chassis for use in existing sleeves
when a grille is needed
• UXAA architectural grille for use with
USC sleeve
WallMaster® 27” Sleeve Exterior Grilles
WSE SLEEVE
Standard Grille
Premium, stamped steel grille
with powder coat paint. Ships
with sleeve. Galvanized steel
inner and outer weather panels
also ship with sleeve.
WSE SLEEVE
Optional Architectural Grille- AG
Premium brushed aluminum
grille.
Installation Accessories (27” sleeve models only)
DK / Drain Kit
Installed at the back of the unit and allows for
attachment to condensate disposal system, if
necessary or desired.
IDK / Internal Drain Kit
New construction applications
where a condensate drain system
has been built into the wall interior.
IMPORTANT:
Operating the air conditioner
with incorrect rear grille or
without Bafe Adapter Kit
(on 19 3/4” deep sleeve) will
recirculate discharge air and
cause compressor overload
to trip.
This will cause the unit to shut
down temporarily and may
lead to premature compressor
failure.
BAK / Bafe Adapter Kit
Necessary when installing in a
sleeve deeper than 16 3/4" deep,
such as Fedders B sleeve
(19 3/4" deep).
CORRECT Vertical Louvers
INCORRECT Horizontal Louvers
Trim ring
IMPORTANT: 1” gap on sides and 1/2”
gap at top, which allows installation into
varying sleeve sizes, can be covered by
two-piece trim ring that ts over the
chassis front. Trim ring comes standard
with chassis.
NEW!
UXAA- Architectural grille for USC sleeve
Uni-Fit® installs in many existing sleeves.
Carrier
(51S
Series)
Sleeve
Dimensions
Height
(inches)
Width
(inches)
Depth
(inches)
NOTE: Chassis requires USC sleeve for new installations (sold and shipped separately)
6
Friedrich
USC Sleeve Amana
15 1/215 5/816 7/816 3/415 3/415 5/816 1/215 1/4
25 7/82625 3/42726 3/42625 7/825 1/2
16 3/416 7/818 5/816 3/4 or 19 3/41516 7/817 1/8 or 2316, 17 1/2 or 22
Friedrich WSE
Fedders/
Emerson/
Emer-
son/
Fedders
GE/
Hot-
pointWhirlpool
White-Westinghouse/
Frigidaire/ Carrier (52F
Series)
Uni-Fit® 26” Sleeve Exterior Grilles
Optional Architectural Grille UXAAUSC Sleeve Standard Grille
Sleeve/Chassis Dimensions
STANDARD GRILLE – Ships with USC sleeve
Expanded aluminum grille designed for use with USC sleeve.
REPLACEMENT GRILLE – Ships with US/UE chassis
Black plastic for use on existing sleeves without any grille.
IMPORTANT:
When installing into an existing sleeve, consult Installation
Section of your Installation/Operation Manual to determine
whether or not the grille needs to be replaced and/or a bafe
adapter should be used.
Trim ring
IMPORTANT:
US= 3 3/8”, UE= 2 7/8”
US chassis w/front fully installed into USC sleeve extends
into room 3 3/8”. UE chassis w/front fully installed into
USC sleeve extends into room 2 7/8”. 1” gap on sides and
1
/2” gap at top can be covered by two-piece trim ring that
WallMaster Heat Pump heating information (shown inred) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red)
indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
WALLMASTER HEAT PUMP
HEATING PERFORMANCE: Cha nge-over fro m heat pump operati on to resistanc e
operation on models indicated is automatic at a preset outside ambient temperature
of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does
not exceed the resistance heating capacity rating of the unit, the heating performance will be satisfactory.
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature) and terminated
at 43°F (outdoor coil temperature). During defrost, the compressor stops and the
electric heat starts, then operates with the fan to maintain indoor comfort. Below
43°F, the unit remains in electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent
condensate from freezing inside drain pan.
Note: all models will produce condensate. If condensate disposal is desired, an
optional drain kit is available.
Net
Lbs.
Ship
Weight
Lbs
Plug Face/ Circuit Rating
Circuit
WallMaster
®
Model Number
WS08C10D, WS10C10D,
WS12 C10D
WS10C30D, W S12C30D,
WS16 C3 0
WE10C33D, WE12C33D,
WE16C33, WY09C 33D, WY12C3 3
®
Uni-Fit
Model Number
US08D10B, UE08D11B
US10D10B, US12D10B
US10D30B, US12D30B,
US14D30B
Rating
Breaker
or T-D Fuse
125V - 15A5 - 15P6
250V - 15A6 - 15P6
UE10D33B, UE12D33B250V - 20A6 - 20P6
Plug
Face
(NEMA#)
Power cords are located on front left of WallMaster models and on front right of Uni-Fit models.
Due to continuing research in new energy-saving technology, specications are subject to change without notic e.
ENERGY STAR
As an
models meet the
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR®
ENERGY STAR
®
guidelines for energy efciency.
Power
Cord
Length
(ft.)
Wall
Outlet
Appearance
Model
WallMaster
WSE Sleeve18"27 1/4" 18"
Chassis18 1/2" 30 1/2" 29"
®
Uni-Fit
USC Sleeve17 7/8"28" 19 1/4"
US Chassis17 1/4" 27 3/4" 22 1/4”
UE Chassis17 1/4" 27 3/4” 22 1/4”
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity
cost of $ .12 per kWh. For more information, visit www.ftc.gov/energy.
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665
www.friedrich.com
Commercial_Thru-the-wall_Air_Conditioners_Brochure_2014 Printed in USA
Carton Dimensions
Height Widt h Depth
®