Friedrich MW12Y1F, MW09Y1F User Manual

MANUAL DE FUNCIONAMIENTO
Friedrich Air Conditioning Co.
4200 N. Pan Am
San Antonio, Texas 78218 USA
Tel. (210) 357-4400 Fax (210) 357-4490
Visit us at www. friedrich. com
HEAT&COOLING MODEL (REVERSE CYCLE)
ROOM AIR CONDITIONER
WALL MOUNTED TYPE
Indoor Unit
MW09Y1F
OPERATING MANUAL
MODE D’EMPLOI
MW12Y1F
Outdoor Unit
MR09Y1F MR12Y1F
English
Français
KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE
P/N9314787010-01
Ÿ
*
&
§
+
£
%
^
¡
º
ª
(
)
¢
_
5 6 4 7 8
OPERATION TIMER
SUPER QUIET
SWING
=
A
B
D
C
9
3
1
E
F
G
2
Fig. 1
Fig. 2
Fig. 3
Fig. 5
Fig. 4
Fig. 6
Fig. 8
Fig. 7
This figure shows the control display when all indicator lamps are on. It may differ from the actual display.
CONTENTS
SAFETY PRECAUTIONS .................................... En-1
NAME OF PARTS ................................................ En-2
FEATURES AND FUNCTIONS............................ En-3
PREPARATION .................................................... En-4
OPERATION ........................................................ En-5
TIMER OPERATION ............................................ En-7
SLEEP TIMER OPERATION ................................ En-8
SAFETY PRECAUTIONS
DANGER!
CAUTION!
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
When moving, consult authorized service personnel for disconnection and installa­tion of the unit.
Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow.
Do not insert fingers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by disconnecting the power supply
cord and so on.
Take care not to damage the power supply cord.
In the event of a malfunction (burning smell, etc.), immediately stop operation, dis-
connect the power supply plug, and consult authorized service personnel.
If the power supply cord of this appliance is damaged, it should only be replaced by the authorized service personal, since special purpose tools and specified cord are required.
Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not pull power supply cord.
Turn off power source when not using the unit for extended periods.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
Avoid installing the air conditioner near a fireplace or other heating apparatus.
When installing the indoor and outdoor unit, take precautions to prevent access to
infants.
Do not use inflammable gases near the air conditioner.
ADJUSTING THE DIRECTION OF
AIR CIRCULATION .............................................. En-9
SWING OPERATION......................................... En-10
MANUAL AUTO OPERATION .......................... En-10
CLEANING AND CARE ..................................... En-11
TROUBLESHOOTING ....................................... En-12
OPERATING TIPS.............................................. En-13
TYPE HEAT & COOL MODEL TYPE MODÈLE RÉVERSIBLE TIPO MODELO DE REFRIGERACIÓN Y CAlEFACCÓN
MODEL MODÈLE MODELO
INDOOR UNIT UNIDAD INTERIOR UNITÉ INTÉRIEURE
OUTDOOR UNIT UNIDAD EXTERIOR UNITÉ EXTÉRIEURE
MW12Y1F
MR12Y1F
SPECIFICATIONS
POWER SUPPLY ............................................................................................................................................................................................................................................................... 115 V~60 Hz
COOLING
CAPACITY ..................................................................................................................................................................................................................................................................
INPUT POWER ...................................................................................................................................................................................................................................................................
CURRENT ............................................................................................................................................................................................................................................................................... 9.9 A
HEATING
CAPACITY .................................................................................................................................................................................................................................................................
INPUT POWER ...................................................................................................................................................................................................................................................................
CURRENT ............................................................................................................................................................................................................................................................................... 9.2 A
12,300 BTU/h
1.07 kW
12,800 BTU/h
0.99 kW
FICHE TECHNIQUE
ALIMENTATION................................................................................................................................................................................................................................................................ 115 V~60 Hz
REFROIDISSEMENT
PUISSANCE FRIGORIFIQUE .....................................................................................................................................................................................................................................
PUISSANCE ABSORBÉE ....................................................................................................................................................................................................................................................
INTENSITÉ ............................................................................................................................................................................................................................................................................. 9,9 A
CHAUFFAGE
PUISSANCE FRIGORIFIQUE .....................................................................................................................................................................................................................................
PUISSANCE ABSORBÉE ...................................................................................................................................................................................................................................................
INTENSITE ............................................................................................................................................................................................................................................................................. 9,2 A
12.300 BTU/h 1,07 kW
12.800 BTU/h
0,99 kW
ESPECIFICACIONES
ALIMENTACIÓN ............................................................................................................................................................................................................................................................... 115 V~60 Hz
REFRIGERACIÓN
CAPACIDAD ...............................................................................................................................................................................................................................................................
ENTRADA DE ALIMENTACIÓN ........................................................................................................................................................................................................................................ 1,07 kW
CORRIENTE ............................................................................................................................................................................................................................................................................ 9,9 A
CALEFACCIÓN
CAPACIDAD ..............................................................................................................................................................................................................................................................
ENTRADA DE ALIMENTACIÓN ........................................................................................................................................................................................................................................
CORRIENTE ............................................................................................................................................................................................................................................................................ 9,2 A
TYPE HEAT & COOL MODEL TYPE MODÈLE RÉVERSIBLE TIPO MODELO DE REFRIGERACIÓN Y CAlEFACCÓN
MODEL MODÈLL MODELO
INDOOR UNIT UNIDAD INTERIOR UNITÉ INTÉRIEURE
OUTDOOR UNIT UNIDAD EXTERIOR UNITÉ EXTÉRIEURE
MW09Y1F
MR09Y1F
12.300 BTU/h
12.800 BTU/h
0,99 kW
SPECIFICATIONS
POWER SUPPLY ............................................................................................................................................................................................................................................................... 115 V~60 Hz
COOLING
CAPACITY ...................................................................................................................................................................................................................................................................
INPUT POWER ...................................................................................................................................................................................................................................................................0.
CURRENT ............................................................................................................................................................................................................................................................................... 7.6 A
HEATING
CAPACITY ...................................................................................................................................................................................................................................................................
INPUT POWER ...................................................................................................................................................................................................................................................................0.
CURRENT ............................................................................................................................................................................................................................................................................... 6.5 A
9,700 BTU/h
82 kW
9,600 BTU/h
69 kW
FICHE TECHNIQUE
ALIMENTATION................................................................................................................................................................................................................................................................ 115 V~60 Hz
REFROIDISSEMENT
PUISSANCE FRIGORIFIQUE .......................................................................................................................................................................................................................................
PUISSANCE ABSORBÉE ...................................................................................................................................................................................................................................................0,
INTENSITÉ ............................................................................................................................................................................................................................................................................. 7,6 A
CHAUFFAGE
PUISSANCE FRIGORIFIQUE .......................................................................................................................................................................................................................................
PUISSANCE ABSORBEE ....................................................................................................................................................................................................................................................
INTENSITE ............................................................................................................................................................................................................................................................................. 6,5 A
9.700 BTU/h 82 kW
9.600 BTU/h
0,69 kW
ESPECIFICACIONES
ALIMENTACIÓN ............................................................................................................................................................................................................................................................... 115 V~60 Hz
REFRIGERACIÓN
CAPACIDAD ................................................................................................................................................................................................................................................................
ENTRADA DE ALIMENTACIÓN ........................................................................................................................................................................................................................................0,
CORRIENTE ............................................................................................................................................................................................................................................................................ 7,6 A
CALEFACCIÓN
CAPACIDAD ................................................................................................................................................................................................................................................................
ENTRADA DE ALIMENTACIÓN ........................................................................................................................................................................................................................................ 0,69 kW
CORRIENTE ............................................................................................................................................................................................................................................................................ 6,5 A
9.700 BTU/h 82 kW
9.600 BTU/h
En-1
Fig. 1 Indoor Unit
Fig. 6 Remote Control Unit
1 Operating Control Panel (Fig. 2) 2 MANUAL AUTO button
3 Indicator Lamps (Fig. 3) 4 Remote Control Signal Receiver 5 OPERATION Indicator Lamp (red) 6 TIMER Indicator Lamp (green)
If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See Page 12 Auto Restart).
7 SUPER QUIET Indicator Lamp (green) 8 SWING Indicator Lamp (orange)
9 Intake Grille (Fig. 4) 0 Air Filter A Air Flow Direction Louver B Right-Left Louver
(behind Air Flow Direction Louver)
C Drain Hose D Air Cleaning Filter (optional)
Fig. 5 Outdoor Unit
E Intake Port F Outlet Port G Pipe Unit
H MASTER CONTROL button I SET TEMP. / SET TIME buttons (+/-) J Signal Transmitter K TIMER button L FAN CONTROL button M START/STOP button N SLEEP button O SET button P SWING button Q ACL button R TIME ADJUST button
Rear side (Fig. 7) S TEST RUN
Touch the two metal contacts with a
metallic object to send the signal to perform a test run.
Perform a test run only when installing the air conditioner. If the signal to perform a test run is received during normal operation, the air conditioner’s thermostat will malfunction.
If the signal to perform a test run is re­ceived during normal operation, the unit will switch to the test operation mode and the indoor unit’s OPERATION and TIMER indicator lamps will flash simultaneously.
To stop the test operation mode, press the
START/STOP button to stop the air conditioner.
Refer to the folded out page on the cover.
T Remote Control Unit Display (Fig. 8) U Transmit Indicator V Clock Display W Operating Mode Display X T imer Mode Display Y Fan Speed Display Z Temperature Set Display [ T imer Set Indicator \ Temperature Set Indicator
En-2
En-3
PREPARATION
Turn on the Power
In the case of a direct line connection, turn on the circuit breaker.
Load Batteries (R03 / LR03
××
× 2)
××
Press and slide the battery compartment lid on the re-
1
verse side to open it.
Slide in the direction of the arrow while pressing the mark.
Insert batteries.
2
Be sure to align the battery polarities ( ) correctly.
Close the battery compartment lid.
3
Set the Current time
Press the TIME ADJUST button (Fig. 6 R).
1
Use the tip of a ball-point pen or other small object to press the button.
CAUTION!
Take care to prevent infants from accidentally swallowing batteries.
When not using the remote control unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit.
If leaking battery fluid comes in contact with your skin, eyes, or mouth, immedi­ately wash with copious amounts of water, and consult your physician.
Dead batteries should be removed immediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority.
Do not attempt to recharge dry batteries.
Never mix new and used batteries, or batteries of different types. Batteries should last about one year under normal use. If the remote control unit’s operating range becomes appre­ciably reduced, replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object.
Use the , / - SET TEMP. / SET TIME buttons (Fig. 6
2
I) to adjust the clock to the current time.
, button: Press to advance the time.
- button: Press to reverse the time.
(Each time the buttons are pressed, the time will be advanced/reversed in one-minute increments; hold the buttons depressed to change the time quickly in ten-minute increments.)
Press the TIME ADJUST button again.
3
This completes the time setting and starts the clock.
To Use the Remote Control Unit
The Remote Control Unit must be pointed at signal receiver (Fig. 1 4) to operate correctly.
Operating Range: About 7 meters.
When a signal is properly received by the air conditioner, a beeping sound will
be heard.
If no beep is heard, press the Remote Control Unit button again.
Remote Control Unit Holder
Insert
Press in
Screws
Slide up
Pull out
1 Mount the Holder. 2 Set the Remote Control
Unit.
3 To remove the Remote
Control Unit (when use at hand).
En-4
OPERATION
To Select Mode Operation
Press the START / STOP button (Fig.6 M).
1
The indoor unit’s OPERATION indicator lamp (red) (Fig. 3 5) will light. The air conditioner will start operating.
Press the MASTER CONTROL button (Fig.6 H) to se-
2
lect the desired mode.
Each time the button is pressed, the mode will change in the following order.
s
AUTO COOL DRY
HEAT FAN
About three seconds later, the entire display will reappear.
To Set the Thermostat
Press the SET TEMP. / SET TIME buttons (Fig. 6 I).
, button: Press to raise the thermostat setting.
- button: Press to lower the thermostat setting.
Thermostat setting range:
AUTO .................................. 64 to 88 °F
Heating ............................... 60 to 88 °F
Cooling/Dry ........................ 64 to 88 °F
The thermostat cannot be used to set room temperature during the FAN mode (the temperature will not appear on the remote control
About three seconds later, the entire display will reappear.
The thermostat setting should be considered a standard value, and may differ somewhat from the actual room temperature.
unit’s display).
s
t
s
t
Example: When set to COOL.
Example: When set to 86 °F.
To Set the Fan Speed
Press the FAN CONTROL button (Fig. 6 L).
Each time the button is pressed, the fan speed changes in the following order:
AUTO HIGH MED LOW QUIET
About three seconds later, the entire display will reappear.
When set to AUTO:
Heating : Fan operates so as to optimally circulate warmed air.
However, the fan will operate at very low speed when the tempera­ture of the air issued from the indoor unit is low.
Cooling : As the room temperature approaches that of the thermostat setting,
the fan speed becomes slower.
Fan : The fan runs at the low fan speed.
The fan will operate at a very low setting during Monitor operation and at the start of the Heating mode.
When set to QUIET:
SUPER QUIET operation begins. The indoor unit’s airflow will be reduced for qui­eter operation.
SUPER QUIET operation cannot be used during Dry mode. (The same is true when dry mode is selected during AUTO mode operation.)
Heating and Cooling performance will be reduced somewhat during SUPER QUIET operation.
ssss
s
To Stop Operation
Example: When set to AUTO.
Press the START/STOP button (Fig.6 M).
The OPERATION indicator lamp (red) (Fig. 3 5) will go out.
En-5
OPERATION
About AUTO CHANGEOVER Operation
AUTO: When AUTO CHANGEOVER operation first selected, the fan will oper-
ate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode.
If the differance between thermostat setting and actual room tempera­ture is more than +4 °F Cooling
If the difference between thermostat setting and actual room tempera­ture is within ±4 °F Monitor operation If the difference between thermostat setting and actual room tempera­ture is more than –4 °F Heating operation
When the air conditioner has adjusted your room’s temperature to near the thermostat setting, it will begin monitor operation. In the monitor operation mode, the fan will operate at low speed. If the room tem­perature subsequently changes, the air conditioner will once again select the appropriate operation (Heating, Cooling) to adjust the tem­perature to the value set in the thermostat.
(The monitor operation range is ±4 °F relative to the thermostat setting.)
If the mode automatically selected by the unit is not what you wish, select one of the mode operation (HEAT, COOL, DRY, FAN).
About Mode Operation
Heating: Use to warm your room.
When Heating mode is selected, the air conditioner will operate at very low fan speed for about 3 to 5 minutes, after which it will switch to the selected fan setting. This period of time is provided to allow the indoor unit to warm up before begin full operation.
When the room temperature is very low, frost may form on the outside unit, and its performance may be reduced. In order to remove such frost, the unit will automatically enter the defrost cycle from time to time. During Automatic Defrosting operation, the OPERATION indica­tor lamp (red) will flash, and the heat operation will be interrupted.
Cooling: Use to cool your room. Dry: Use for gently cooling while dehumidifying your room.
You cannot heat the room during Dry mode.
During Dry mode, the unit will operate at low speed; in order to adjust
room humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when adjusting room humidity.
The fan speed cannot be changed manually when Dry mode has been selected.
Fan: Use to circulate the air throughout your room.
During Heating mode:
Set the thermostat to a temperature set­ting that is higher than the current room temperature. The Heating mode will not operate if the thermostat is set lower than the actual room temperature.
During Cooling/Dry mode:
Set the thermostat to a temperature set­ting that is lower than the current room temperature. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will oper­ate).
During Fan mode:
You can not use the unit to heat and cool your room.
En-6
TIMER OPERATION
Before using the timer function, be sure that the Remote Control Unit is set to the correct current time, see page 4.
To Use the ON timer or OFF timer
Press the START / STOP button (Fig. 6 M).
1
(if the unit is already operating, proceed to step 2).
The indoor unit's OPERATION Indicator Lamp (red) (Fig. 3 5) will light.
Press the TIMER button (Fig. 6 K) to select the OFF
2
timer or ON timer operation.
Each time the button is pressed the timer function changes in the following order:
RESET OFF ON
PROGRAM (OFF ON, OFF ON)
The indoor unit's green TIMER lamp (Fig. 3 6) will light.
Use the SET TEMP. / SET TIME buttons (Fig. 6 I) to
3
adjust the desired OFF time or ON time.
Set the time while the time display is flashing (the flashing will continue for about five seconds).
, button: Press to advance the time.
- button: Press to reverse the time.
About five seconds later, the entire display will reappear.
To Cancel the Timer
Use the TIMER button to select “TIMER RESET.” The air conditioner will return to normal operation.
To Change the Timer Settings
Perform steps 2 and 3.
To Stop Air Conditioner Operation while the Timer is Operating
Press the START / STOP button.
To Change Operating Conditions
If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.
To Use the Program Timer
Press the START / STOP button (Fig. 6 M).
1
(if the unit is already operating, proceed to step 2).
The indoor unit's OPERATION Indicator Lamp (red) (Fig. 3 5) will light.
Set the desired times for OFF timer and ON timer.
2
See the section “To Use the ON Timer or OFF Timer” to set the desired mode and times. About three seconds later, the entire display will reappear. The indoor unit's TIMER Indicator Lamp (green) (Fig. 3 6) will light.
Press the TIMER button (Fig. 6 K) to select the
3
PROGRAM timer operation (OFF
ON or OFF ON
will display).
The display will alternately show “OFF timer” and “ON timer”, then change to show the time setting for the operation to occur first.
The program timer will begin operation. ( If the ON timer has been
selected to operate first, the unit will stop operating at this point).
About five seconds later, the entire display will reappear.
About the Program Timer
The program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.
The first timer function to operate will be the one set nearest to the current time. The order of operation is indicated by the arrow in the Remote Control Unit's Display (OFF
One example of Program timer use might be to have the air conditioner automatically stop ( OFF timer ) after you go to sleep, then start ( ON timer) automatically in the morning before you arise.
ON or OFF ON ).
To Cancel the Timer
Use the TIMER button to select “TIMER RESET.” The air conditioner will return to normal operation.
To Change the Timer Settings
1. Follow the instructions given in the section "To Use the ON Timer or OFF Timer" to select the timer setting you wish to change.
2. Press the TIMER button to select either OFF
ON or OFF ON.
To Stop Air Conditioner Operation while the Timer is Operating
Press the START / STOP button.
To Change Operating Conditions
If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.
En-7
SLEEP TIMER OPERATION
Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.
To Use the SLEEP Timer
While the air conditioner is operating or stopped, press the SLEEP button (Fig. 6 N).
The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) lights and the TIMER Indicator Lamp (green) (Fig. 3 6) light.
To Change the Timer Settings
Press the SLEEP button (Fig. 6 N) once again and set the time using the SET TEMP./SET TIME ( , / - ) buttons (Fig. 6 I).
Set the time while the Timer Mode Display is flashing (the flashing will continue about five seconds).
, button: Press to advance the time.
- button: Press to reverse the time.
About five seconds later, the entire display will reappear.
About the SLEEP Timer
To prevent excessive cooling during sleep, the SLEEP timer function automatically modifies the thermostat setting in accon­dance with the time setting. When the set time has elapsed, the air conditioner completely stops.
During Heating operation :
When the SLEEP timer is set, the thermostat setting is automatically lowered 2 °F every thirty minutes. When the thermostat has been lowered a total of 8 °F, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.
During Cooling/Dry operation:
When the SLEEP timer is set, the thermostat setting is auto­matically raised 2 °F every sixty minutes. When the thermo­stat has been raised a total of 4 °F, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.
To Cancel the Timer:
Use the TIMER button to select “TIMER RESET”. The air conditioner will return to normal operation.
To Stop the Air Conditioner During Timer Operation:
Press the START/STOP button.
SLEEP timer setting
30 minutes
1 hour
2 °F
1 hour 30 minutes
4 °F
Set time
6 °F
8 °F
SLEEP timer setting
1 hour
Set time
2 °F
4 °F
En-8
ADJUSTING THE DIRECTION OF AIR CIRCULATION
Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s SET button. Horizontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers. Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.
Vertical Air Direction Adjustment
Press the SET button (Fig. 6 O).
Each time the button is pressed, the air direction range will change as follows:
2 3 4 5 6 7
1
Types of Air flow Direction Setting:
1,2,3 : During Cooling / Dry modes 4,5,6,7 : During Heating mode 1,2,3,4,5,6,7 : During Fan mode
The remote Control Unit’s display does not change.
Use the air direction adjustments within the ranges shown above.
The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling / Dry / Fan mode : Horizontal flow 1 During Heating mode : Downward flow 7
During AUTO mode operation, for the first minute after beginning operation, airflow will be horizontal 1; the air direction cannot be adjusted during this period.
R
DANGER!
Never place fingers or foreign objects in­side the outlet ports, since the internal fan operates at high speed and could cause personal injury.
Always use the remote control unit’s SET button to adjust the vertical airflow louvers. Attempting to move them manually could result in improper operation; in this case, stop operation and restart. The louvers should begin to operate properly again.
During Cooling and Dry modes, do not move the vertical air direcion louvers outside their proper operating range for the mode (1 - 3) and into the fan region (4 - 7) ; using the louvers in the fan region will cause moisture to condense near the air outlet, and water may drop onto the floor. During the Cooling / Dry modes, if the louvers are operated outside the range 1 - 3 for more than 30 minutes, they will automatically return to position 3 range.
When used in a room with infants, chil­dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.
Right-Left Adjustment
Adjust the Right-Left louvers.
Move the Right-Left louvers to adjust air flow in the direction you prefer.
knob
knobs (three places)
En-9
R
DANGER!
When adjusting the Right-Left Louvers, it is necessary to stop the Air-Conditioner first and make sure that it stops completely before adjusting the direction.
SWING OPERATION
Begin air conditioner operation before performing this procedure.
To select SWING Operation
Press the SWING button (Fig. 6 P).
The SWING indicator lamp (orange) (Fig. 3 8) will light. In this mode, the Air Flow Direction Louvers will swing automatically to direct the air flow both up and down.
To Stop SWING Operation
Press the SWING button (Fig. 6 P) once again.
The SWING indicator lamp (orange) (Fig. 3 8) will go out. Airflow direction will return to the setting before swing was begun.
About Swing Operation
The range of swing is relative to the currently set airflow direction.
The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.
If the Remote Control Unit’s SET button is pressed during swing, swing will be canceled, and the Air flow direction will return to the setting before swing was setted.
MANUAL AUTO OPERATION
Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable.
How To Use the Main Unit Controls
Press the MANUAL AUTO button (Fig. 2 2) on the main unit control panel.
To stop operation, press the MANUAL AUTO button once again. (Controls are located inside the Intake Grille)
CAUTION!
Do not press the MANUAL AUTO button with wet hands or pointed objects, otherwise an electric shock or malfunction may occur.
When the air conditioner is operated with the controls on the Main Unit, it will operate under the same mode as the AUTO mode selected on the Re­mote Control Unit (see page 6).
The fan speed selected will be “AUTO” and the thermostat setting will be standard.
En-10
CLEANING AND CARE
WARNING!
CAUTION!
Before cleaning the plasma filter unit, be sure to turn off the power supply to the air conditioner. Electric shock may result.
Make sure the plasma filter unit is properly mounted before cleaning or performing other tasks on it. If the unit is not properly mounted, it could fall off and cause damage or injury.
You can be injured if you touch the heat exchanger when removing or installing the plasma filter unit. Do not insert your fingers between the plasma filter unit and the heat exchanger.
Cleaning the Intake Grille
1. Remove the Intake Grille.
1 Place your fingers at both lower ends of the grille
panel, and lift forward; if the grille seems to catch partway through its movement, continue lifting up­ward to remove.
2 Pull past the intermediate catch and open the Intake
Grill wide so that it become horizontal.
Intake Grille
Intake Grille
Mounting
shaft
Knob
2. Clean with water.
Remove dust with a vacuum cleaner; wipe the unit with warm water, then dry with a clean, soft cloth.
Cleaning the Air Filter
1. Open the Intake Grille, and remove the air filter.
Lift up the air filter’s handle, disconnect the two lower tabs, and pull out.
Air filter handle
2. Remove dust with a vacuum cleaner or by washing.
After washing, allow to dry thoroughly in a shaded place.
3. Replace the Air Filter and close the Intake Grille.
1 Align the sides of the Air Filter with the panel, and
push in fully, making sure the two lower tabs are re­turned properly to their holes in the panel.
3. Replace the Intake Grille.
1 Pull the knobs all the way. 2 Hold the grille horizontal and set the left and right
mounting shafts into the bearings at the top of the panel.
Intake Grille
Intake Grille
When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.
When cleaning the unit’s body, do not use water hotter than 108 °F, harsh abrasive cleansers, or volatile agents like benzene or thinner.
Do not expose the unit body to liquid insecticides or hairsprays.
When shutting down the unit for one month or more, first allow the fan mode to operate continuously for about one-half
day to allow internal parts to dry thoroughly.
Mounting shaft
Bearing
Knob
Mounting
shaft
Knob
2 Close the Intake Grille.
(For purposes of example, the illustration shows the unit without Intake Grille installed.)
Dust can be cleaned from the Air Filter either with a vacuum cleaner, or by washing the filter in a solution of mild detergent and warm water. If you wash the filter, be sure to allow it to dry thoroughly in a shady place before reinstalling.
If dirt is allowed to accumulate on the Air Filter, air flow will be reduced, lowering operating efficiency and in­creasing noise.
During periods of normal use, the Air Filters should be cleaned every two weeks.
Air filter handle
En-11
TROUBLESHOOTING
WARNING!
Before requesting service, perform the following checks:
NORMAL
FUNCTION
Doesn’t operate immediately:
Noise is heard:
Smells:
Mist or steam are emitted:
Airflow is weak or stops:
Water is produced from the outdoor unit:
In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the Power Supply Plug, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to disconnect the Power Supply Plug or turn off your circuit breaker to ensure that power is completely off.
Symptom
If the unit is stopped and then immediately started again, the com­pressor will not operate for about 3 minutes, in order to prevent fuse blowouts. Whenever the Power Supply Plug is disconnected and then re-
connected to a power outlet, the protection circuit will operate for about 3 minutes, preventing unit operation during that period.
During operation and immediately after stopping the unit, the sound of water flowing in the air conditioner’s piping may be heard. Also, noise may be particularly noticeable for about 2 to 3 minutes after starting operation (sound of coolant flowing).
During operation, a slight squeaking sound may be heard. This is the result of minute expansion and contraction of the front cover due to temperature changes.
During Heating operation, a sizzling sound may be heard occasional.
This sound is produced by the Automatic Defrosting operation.
Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, tobacco, etc.) which have been taken into the air conditioner.
During Cooling or Dry operation, a thin mist may be seen emitted from the indoor unit. This results from the sudden Cooling of room air by the air emitted from the air conditioner, resulting in condensation and misting.
During Heating operation, the outdoor unit’s fan may stop, and steam may be seen rising from the unit. This is due to Automatic Defrosting operation.
When Heating operation is started, fan speed is temporarily very low, to allow internal parts to warm up.
During Heating operation, if the room temperature rises above the thermostat setting, the outdoor unit will stop, and the indoor unit will operate at very low fan speed. If you wish to warm the room further, set the thermostat for a higher setting.
During Heating operation, the unit will temporarily stop opera­tion (between 7 and 15 minutes) as the Automatic Defrosting mode operates. During Automatic Defrosting operation, the OPERATION indicator lamp will flash.
The fan may operate at very low speed during Dry operation or when the unit is monitoring the room’s temperature.
During SUPER QUIET operation, the fan will operate at very low speed.
In the monitor AUTO operation, the fan will operate at very low speed.
During Heating operation, water may be produced from the out­door unit due to Automatic Defrosting operation.
Problem
See Page
13
13
13
5
5
5
13
En-12
TROUBLESHOOTING
Symptom
CHECK ONCE
MORE
If the problem persists after performing these checks, or if you notice burning smells, or the TIMER indicator lamp (Fig. 3 6) flashes, immediately stop operation, disconnect the Power Supply Plug, and consult authorized service personnel.
Doesn’t operate at all:
Poor Cooling or Heating performance:
The unit operates differently from the Remote Control Unit’s setting:
Is the Power Supply Plug disconnected its outlet?
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the timer operating?
Is the air filter dirty?
Air the air conditioner’s intake grille or outlet port blocked?
Did you adjust the room temperature settings (thermostat)
correctly?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and computers inside the room, or are there too many people in the room?
Is the unit set for SUPER QUIET operation?
Are the Remote Control Unit’s batteries dead?
Are the Remote Control Unit’s batteries loaded properly?
Items to check
See Page
7 - 8
5
4
OPERATING TIPS
Operation and Performance
Heating Performance
This air conditioner operates on the heat-pump principle, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insuffi­cient heating performance is being produced, we recom­mend you use this air conditioner in conjunction with another kind of heating appliance.
Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air con­ditioner until the room is heated.
AUTO Restart
In Event of Power Interruption
The air conditioner power has been interrupted by a power failure. The air conditioner will then restart automatically in its previous mode when the power is restored.
Operated by setting before the power failure.
Microcomputer-controlled Automatic Defrosting
When using the Heating mode under conditions of low outdoor temperature and high humidity, frost may form on the outdoor unit, resulting in reduced operating performance.
In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Auto­matic Defrosting function. If frost forms, the air condi­tioner will temporarily stop, and the defrosting circuit will operate briefly (for about 7-15 minutes).
During Automatic Defrosting operation, the OPERATION indicator lamp (red) will flash.
If a power failure occurs during TIMER operation, the timer will be reset and the unit will begin (or stop) operation at the new time setting. In the event that this (kind of timer fault occurs the TIMER Indicator Lamp will flash (see Page. 3)).
Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily disconnect the Power Supply Plug, reconnect it, and then use the Remote Control Unit to resume operation.
En-13