Ductless Split Systems
Wall-mounted, Single-zone Cool Only
PURCHASER P.O. # DATE
PROJECT LOCATION
ENGINEER ARCHITECT
SUBMITTED BY FOR APPROVAL FOR REFERENCE
ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL
Features
• Inverter technology (variable speed compressor)
• High efciency for low operating cost
• DiamonGold Advanced Corrosion Protection™
• Auto dr y indoor coil
• Cooling/Heating/Fan mode
• Surge cool
• Natural air ow
• 4-Way auto swing
• Ultra quiet operation
• Sleep mode
• Dehumidifying mode
• Auto restart
• Built-in low ambient standard, down to 14ºF (Cooling Mode)
• 24-hour on-off timer
• Multiple ease of installation features
All Inverter line
Ductless_Wall-mounted_Single_Zone_Cool_Only_Submittal_2014

SPECIFICATIONS
PERFORMANCE RATINGS Single Wall Mounted - Cool Inv
SYSTEM MODEL NO. M09CJ M12CJ M18CJ M24CJ
INDOOR MODEL MW09C1J MW12C1J MW18C3J MW24C3J
OUTDOOR MODEL MR09C1J MR12C1J MR18C3J MR24C3J
SPECIFICATIONS
CAPACITY COOLING (RATED) Btu 9,000 11,200 17,000 22,000
CAPACITY COOLING (MIN~MAX) Btu 3,070~12,120 3,070~13,660 3,070~20,470 3,070~26,270
CAPACITY HEATING (RATED) Btu N/A N/A N/A N/A
CAPACITY HEATING (MIN~MAX) Btu N/A N/A N/A N/A
COOLING AMPS 6 8.4 7 8.7
HEATING AMPS N/A N/A N/A N/A
SENSIBLE HEAT RATIO .89 .83 .79 .81
SEER 21.5 21.5 18.0 20.0
EER 13.3 12.5 12.0 10.8
HSPF N/A N/A N/A N/A
ENERGY STAR YES YES YES No
MOISTURE REMOVAL Pts/h 2.6 3.0 5.3 6.0
AIRFLOW (QUIET, LOW, MED, HIGH) CFM 124/212/272/335 124/212/272/335 300/399/509/622 300/424/629/742
SOUND RATING - INDOOR dB-A 19 / 24 / 33 / 38 19 / 24 / 33 / 39 29 / 35 / 40 / 45 29 / 35 / 40 / 46
SOUND RATING - OUTDOOR dB-A 45 45 53 54
OPERATING RANGE (COOLING)(WIND BAFFLE) °F 14.0(0)~118.4 14.0(0)~118.4 14.0(0)~118.4 14.0(0)~118.4
OPERATING RANGE (HEATING) °F N/A N/A N/A N/A
EST. YEARLY OPERATING COST $ 61 81 127 183
ELECTRICAL DATA
POWER SOURCE V 115/60/1 115/60/1 208/230/60/1 208/230/60/1
MINIMUM AMPACITY A 12 12 19 19
COOLING WATTS W 677 896 1416 2037
MAX. TD FUSE/BREAKER A 20 20 25 25
POWER AND COMMUNICATION CABLE No. x AWG 4 x 18 4 x 18 4 x 18 4 x 18
REFRIGERATION SYSTEM
REFRIGERANT R410A R410A R410A R410A
CONNECTIONS Flare Flare Flare Flare
LIQUID LINE O.D. in 1/4 1/4 1/4 3/8
SUCTION LINE O.D. in 3/8 3/8 1/2 5/8
FACTORY PRECHARGE ft 41 41 25 25
REFRIGERANT CHARGE oz 36 36 48 64
MAX. LINE LENGTH ft 66’ 66’ 66’ 98’
MAX. HEIGHT DIFFERENCE ft 33’ 33’ 33’ 49’
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X D in 35-1/4x 11-1/4x 8-5/16 35-1/4x 11-1/4x 8-5/16 40-5/8x 12-7/8x 9-5/8 40-5/8x 12-7/8x 9-5/8
NET WEIGHT lbs 23 23 31 32
SHIPPING WEIGHT lbs 27 27 35 37
OUTDOOR UNIT
W X H X D in 30-5/16x 21-5/16x 11-5/16 30-5/16x21-5/16x11-5/16 34-5/16x25-7/8x12-5/8 34-5/16 x31-1/2 x12-5/8
NET WEIGHT lbs 75 75 108 122
SHIPPING WEIGHT lbs 79 79 115 130
TOTAL NET WEIGHT lbs 97 97 139 154
TOTAL SHIPPING WEIGHT lbs 106 106 150 167
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh. For more
information, visit www.ftc.gov/energy. Due to continuing research in new energy-saving technology,
specications are subject to change without notice.
9k 12k 18k 24k
Refrigeration line sets*
USED WITH
9000 and 12000
BTU indoor units
Length
Liquid Suction Kit#
Ft.
15’ 1/4” 3/8” T32150
35’ 1/4” 3/8” T32350
15’ 1/4” 1/2” T42150
18000 BTU indoor units
24000,30000 and 36000
BTU indoor units
*Insulated line sets are available for all Friedrich split systems in 15 ft. and 35 ft. lengths. Each line set is equipped with are nuts on both ends. Both liquid and suction lines
are insulated. Line sets can be joined together with eld supplied double male connectors.
Each system requires one line set for each indoor unit installed. On multi-zone systems, line sets should be ordered based on individual indoor unit capacities not total system
capacity.
35’ 1/4” 1/2” T42350
15’ 3/8” 5/8” T53150
35’ 3/8” 5/8” T53350
WIRED
CONTROLLER USED WITH
DWC1 All models.
Ductless_Wall-mounted_Single_Zone_Cool_Only_Submittal_2014
Low ambient wind baffle kitThermostat
WIND
BAFFLE
DLAWB1 9000 - 12000 Btu wall-mounted
DLAWB2 18000 - 36000 Btu wall-mounted
USED WITH
single zone models
single zone models