Note :
1. Wiring cable size must comply with the applicable local and national code.
2. Due to our policy of innovation some specifications may be changed without notification.
3. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased owing to ambient conditions during opration.
4. Acceptable operating voltage: 187V-253V
Model Name MW09Y3J MW12Y3J MW18Y3J
Power Supply V, Ø, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Capacity
Cooling Nominal Btu/h 9,000 12,000 18,000
Heating Nominal Btu/h 10,400 13,800 20,800
Casing Color - White White White
Dimensions Body
W x H x D mm 895 × 289 × 210 895 × 289 × 210 1,030 × 325 × 250
W x H x D inch
35-1/4 x 11-3/8 x 8-9/32 35-1/4 x 11-3/8 x 8-9/32 40-9/16 x 12-25/32 x 9-27/32
Net Weight Body kg (lbs) 10.0 (22.1) 10.0 (22.1) 14.5 (32.0)
Heat Exchanger
(Row x Column x Fins per inch) x No.
- (2 x 16 x 23) x 1 (2 x 16 x 23) x 1 (3 x 18 x 22) x 1
Face Area
m2(ft2) 0.22 (2.37) 0.22 (2.37) 0.29 (3.07)
Fan
Type - Cross Flow Fan Cross Flow Fan Cross Flow Fan
Air Flow Rate
H / M / L CMM 7.0 / 6.5 / 6.0 9.5 / 9.0 / 8.5 16.2 / 14.2 / 12.3
H / M / L CFM 247 / 230 / 212 335 / 318 / 300 572 / 501 / 434
Fan Motor
Type - BLDC BLDC BLDC
Output W x No. 14.4 x 1 14.4 x 1 76.0 x 1
Running Current A 0.20 0.20 0.30
Sound Pressure Level H / M / L dB(A) 33 / 30 / 27 39 / 36 / 31 37 / 33 / 28
Piping
Connections
Liquid mm(inch) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)
Gas mm(inch) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2)
Drain (O.D. / I.D.) mm(inch) 21.5(27/32) / 16.0(5/8) 21.5(27/32) / 16.0(5/8) 21.5(27/32) / 16.0(5/8)
Safety Devices
- Fuse Fuse Fuse
-
Thermal Protector for
Fan Motor
Thermal Protector for
Fan Motor
Thermal Protector for
Fan Motor
Power and Communication Cable (included Earth)
No. x AWG 4C x 14 / 18 4C x 14 / 18 4C x 14 / 18
2. Specifications
2 _ Wall mounted
Part 2 Product data_Indoor units