Multi Zone Air Conditioner
SVC MANUAL(Exploded View)
CAUTION
Before Servicing the unit, read the safety
precautions in General SVC manual.
Only for authorized service personnel.
MODEL : MR36TQY3JM
960-920-04

1. Specification
Power Input
(Min.~Rated~ Max.)
Power Supply Cable (Outdoor)
Transmission Cable (Outdoor to Indoor unit )
900 x 1,165 x 370
(35 7/16 x 45 7/8 x 14 9/16)
Max. Number of Connectable Indoor Units
(Rows x Column x FPI) x No.
Discharge Direction(Side/Top)
Air Flow Rate x No. of Fan
Piping length(no add'l refrigerant)
Max. Elevation
Difference
Outdoor Unit
Dimensions
Outdoor Unit
W x H x D
mm(inch)
MR36TQY3JM
(Outdoor)
Note:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27C(80.6F) DB/19C(66.2F) WB
Heating: - Indoor Temperature 20C(68F) DB/15C(59F) WB
Piping Length - Interconnecting Pipi ng Lengt h 7.5m
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
- Outdoor Temperature 35C(95F) DB/24C(75.2F) WB
- Outdoor Temperature 7C(44.6F) DB/6C(42.8F) WB
- Level Difference of Zero
Conversion Formula
kW = Btu/h x 0.0002931
cfm = CMM x 35.3
- 2 -

Restart Delay (3-minutes)
Auto operation(Artificial intelligence) O
PDI(Power Distribution Indicator)
Category
Reliability
Convenience
CAC Network
Function
Note :
• O: Applied, • X: Not applied, • - : No relation,
• Option: Model name & price are different according to options, and assembled in factory with main unit.
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
Function
A4UW363FA2 [MR36TQY3JM]
- 3 -

Field piping
Gas(Ø3/8")
Field piping
Liquid(Ø1/4")
Room D
Room C
Room B
Room A
Room D
Room C
Room B
Room A
Main service
Valve(Gas)
REFRIGERANT FLOW
EEV-D
EEV-C
EEV-B
EEV-A
COOLING
HEATING
Main service
Valve(Liquid)
Th4
Outdoor Unit
Valve
Heat
Exchanger
Reversing
S/V
Th3
Compressor
Th1
Th2
Th1 Thermistor for outdoor air temperature
Th2 Thermistor for condensing temperature
Th3 Thermistor for discharge pipe temperature
Th4 Thermistor for suction pipe temperature
S/V
Solenoid Valve for Hot Gas/Oil Separator
L/P Low Pressure Switch
- 4 -
CN_TH2
CN_TH2
CN_TH3
CN_TH3
CN_H/GAS
/CN_OIL/S
CN_PRESS

Base Assembly,Weld(Outdoor)
Case Assembly,Control(Outdoor)
Cover Assembly,Control(Outdoor)
Cover Assembly,Top(Outdoor)
Motor Assembly,DC,Outdoor
Motor Assembly,DC,Outdoor
Panel Assembly,Front(Outdoor)
Panel Assembly,Rear(Outdoor)
Tube Assembly,Condenser(Out)
Tube Assembly,Suction(Outdoor)
Model: MR36TQY3JM
Loc No. Description
- 7 -

Friedrich Air Conditioning Co. I 10001 Reunion Place, Suite 500 I San Antonio, TX 78216 I 877.599.5665
www.friedrich.com